Contact : +33 1 41 23 50 30 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
Webinars
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Search
Product Selection
DS134RS-230-G
DS50VGPV-1500G/51
DS50VGPV-
G
/51 are type 2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. The DS50VGPV-
G
/51 SPDs incorporates CITEL's exclusive patented 'VG technology' guarantying a total absence of leakAge current and maximum reliability.
DS50VGPV-1000G/51
DS50VGPV-
G
/51 are type 2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. The DS50VGPV-
G
/51 SPDs incorporates CITEL's exclusive patented 'VG technology' guarantying a total absence of leakAge current and maximum reliability.
DS50VGPV-600G/51
DS50VGPV-
G
/51 are type 2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. The DS50VGPV-
G
/51 SPDs incorporates CITEL's exclusive patented 'VG technology' guarantying a total absence of leakAge current and maximum reliability.
DS252C-48DC/G
DS252C-48DC/
G
surge protectors are designed to protect equipment connected to DC power supplies from lightning surges
DS252C-48DC/
G
DS134R-230/G
option
DS134RS
-
230
: output on changeover contact
230
/400 V 3-phase+N
DS134R
-
230
/
G
DSM130R-
230
DS134R-230
option
DS134RS
-
230
: output on changeover contact
230
/400 V 3-phase+N
DS134R
-
230
DSM130R-
230
DS215S-230/G
Compact 1-phase Type 2 (or 3) surge protector -
230
V - Pluggable
230
V single-phase
DS215S-
230
/
G
DSM215-
230
/
G
DS240-230/G
Compact 1-phase Type 2 (or 3) surge protector -
230
V - Pluggable
Option DS240S-
230
/
G
: output on changeover contact
230
V single-phase
DS240-
230
/
G
DSM240-
230
/
G
DS504E-230/G
230
/400 V 3-phase+N
DS504E-
230
/
G
DS132VG-230/G
option DS132VGS-
230
/
G
: output on changeover contact
230
V single-phase
DS132VG-
230
/
G
DSM130VG-
230
+ DSM130VG-
230
/
G
DS74R-230/G
option DS74RS-
230
/
G
: output on changeover contact
230
/400 V 3-phase+N
DS74R-
230
/
G
DSM70R-
230
+ DSM70G-600
DS440-230/G
Compact 3-phase+N Type 2 surge protector -
230
/400 V - Pluggable
Option DS440S-
230
/
G
: output on changeover contact
230
/400 V 3-phase
DS440-
230
/
G
DSM440-230G and DSM440-
230
/GPE
DS44-230/G
option DS44S-
230
/
G
: output on changeover contact
230
/400 V 3-phase+N
DS44-
230
/
G
DSM40-
230
+DSM40G-600
DS44VG-230/G
option DS44VGS-
230
/
G
: output on changeover contact
230
/400 V 3-phase+N
DS44VG-
230
/
G
DSM40VG-
230
+DSM80G-600
DS72R-230/G
option DS72RS-
230
/
G
: output on changeover contact
230
V single-phase
DS72R-
230
/
G
DSM70R-
230
+ DSM70G-600
DS42-230/G
option DS42S-
230
/
G
: output on changeover contact
230
V single-phase
DS42-
230
/
G
DSM40-
230
+DSM40G-600
DS132R-230/G
option DS132RS-
230
/
G
: output on changeover contact
230
V single-phase
DS132R-
230
/
G
DSM130R-
230
+ DSM130R-
230
/
G
DS502E-230/G
230
V single-phase
DS502E-
230
/
G
Range Selection
DS134RS-230-G
Range DS230-DC - DS230-48DC
Range SGP - SGP40
Range DS40VG - DS41VG-120
Range DS130VG - DS131VG-120
Range DS100EG - DS100EG-600
Range DS1000G - DS1000G-600
Range DUT250VG - DUT250VG-300/G
Range DS50VGPVS - DS50VGPVS-1500G/51
Range DS250VG - DS250VG-120
Range DAC50VG - DAC50VG-10-150
Range DAC50VGS - DAC50VGS-10-150
Range DS60VGPV - DS60VGPV-1000G/51
Range DS50VGPV - DS50VGPV-1000G/51
Range DPVN40CVGS - DPVN40CVGS-21Y-1200
Range DACN1-25VGS - DACN1-25VGS-10-440
Range DACN1-35VGS - DACN1-35VGS-10-440
Range MLPX-VG - MLPX1VG-230L-W
Range DACN30VGS-1260 - DACN30VGS-10-1260
Pages
DS134RS-230-G
Citel, surge protection for radiocom site
. Selection of SPDs |Position | | Description | Model | | --- | --- | ---- | --- | | 1 | | 'Quarter Wave' Coaxial SPD type 7/16 |PRC1800-716/MF | | 2 | | Type 1 and Type 2 DC surge protector | DS252C-48DC/
G
| | 3 | | 3-phase+N Type 1+2 AC surge protector | DAC1-13S-31-275 | | 3 | | Type 1+2+3 AC surge protector | DS254VG-300/
G
| | 4 | | 1-pair Data surge protector | DLA-24D3 | | --- | |
Watch video
| | |
Citel, Water Waste Treatment
Implementation of coordinated system of protection against transient overvoltages |--- | --- | --- | --- | | Number | Location | Models | | 1 | AC power - Main electrical panel | DAC1-13VGS-31-275 | | | 1 | | DS254VG-300/
G
| | | 2 | Coaxial antenna - Radio wireless | P8AX | | | 3 | AC power - Distribution panel | DAC40CS-31-275 | | | 4 et 5 | Control circuit - Remote management | DAC15CS-31-275 | | 6 | Telecom-Data-Ethernet | DLA | | | 6 | | MJ8-POE-C6A | | | 7 | Control room | DAC50S-31-275 | | | 7 | | MJ8-POE-C6A | | | 7 | | DLA | | | --- | | Download flyer | | |
Surge Protection for E-Mobility
SPD selection
SPD for main electrical panel | Location | Citel model | SPD type | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Main panel / street cabinet | DAC1-13VGS-31-275 | Type 1+2+3 - Pluggable - DIN rail | | | Domestic main panel | DAC50VGS-31-275 | Type 2 + 3 - Pluggable - DIN rail | | SPD for Charging Terminal | Location | Citel model | SPD type | | | --------------------------------------------- | --------------------------------- | ------------------------------------------------- | ---- | | Wall box - DIN rail | DAC15CS-31-275 | Type 2 (or 3) - Compact - Pluggable - DIN rail | | | Wall box - Printed circuit board mounting | PAC40S-10-275
PAC40GS-10-275 | Type 2 for PCB mounting -
230
Vac single-phase or 3-phase+N |
| | Street lighting charging point | DACN10S-21YG-275 | Type 2+3 - Monobloc - Compact - DIN rail | | | Street lighting charging point | DACN10-L21YG-275 | Type 2 (or 3) - Monobloc - Compact - DIN rail | | | --- | |
Download flyer
| | |
CITEL, surge protectors for security systems
. Selection of SPDs for Security Systems 1 - Surge Protectors for Survey Cameras | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Anolog Camera | MSP-VM230-2P | Combined surge protectors | | | IP Cameras | CRMJ8-POE-C6A | POE++ and 10 Gigabit Ethernet | | | Coaxial lines as Video-transmission | CXC06-B/FM | Coaxial surge protector, BNC connector | | | 10Gigabit Ethernet/POE++ networks | MJ8-POE-C6A | Ethernet surge protector, Shielded RJ45 connections on Cat6A cabling | | | 10Gigabit Ethernet | MJ8-C6A | Ethernet surge protector, Shielded RJ45 connections on Cat6A cabling | |
2 - Surge Protectors for Control Rooms | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Control room | RAK16-E-C6 | 19" Rack surge protector - 10/100/1000BaseT networks | |
3 - Surge Protectors for Main Electrical Panel | Location | Citel models | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | AC network - Main switchboard | DAC1-13S-31-275 | Type 1+2+3 surge protector 3-phase+N | |
4 - Surge Protectors for fire Alarm | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Fire alarm | DAC40CS-11-275 | Type 2 (or 3) surge protector - Compact - Single phase | | | Fire alarm | DAC40CS-31-275 | Type 2 (or 3) surge protector - Compact - 3-phase | |
5 - Surge Protector for Acces Control | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Access control | DLA | Dataline surge protectors - DIN rail mounting | |
6 - Surge Protector for LED Lighting | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Inside the cutouts of led lighting pole | DLPM1-230L |
230
V single phase surge protector - DIN rail mounting | |
| --- | --- | |
Download flyer
|
Watch video
| | | |
PDF Found
DS134RS-230-G
DS130RS_D171017A_DB.pdf
.: +49 234 / 54 72 10 • Fax: +49 234 / 54 72 199 • e-mail: info@citel.de • www.citel.de • Document could be modifi ed without notice Datenblatt D171017A CITEL Artikel Bezeichnung DS131RS-400 DS131RS-
230
DS131RS-120 Nennspannung Un
230
/400 V
230
/400 V 120/208 V Höchste Dauerspannung AC Uc AC 440 Vac 255 Vac 150 Vac Nennfrequenz fn 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz TOV-Spannung (L-N) 5sec. ... Charakteristik UT 770 Vac / 120 min. sicher 440 Vac / 120 min. sicher
230
Vac / 120 min. sicher Schutzleiterstrom - Leckstrom (CM) bei Uc Ipe < 1 mA < 1 mA < 1 mA Folgestrom If keiner keiner keiner Folgestromlöschfähigkeit Ifi unendlich unendlich unendlich Ansprechzeit tA < 20 ns < 20 ns < 20 ns Nennableitstoßstrom / Pol 15 x 8/20 µs Impulse In 20 kA 20 kA 20 kA Max. ... Ableitfähigkeit @ 10/350 µs Iimp 12,5 kA 12,5 kA 12,5 kA Spezifi sche Energie pro Pol W/R 40 kJ / Ohm 40 kJ / Ohm 40 kJ / Ohm Schutz Modus CM CM CM Schutzpegel CM/DM* @ In (8/20µs) und (1,2/50µs) Up CM/ Up DM 1,7 kV / - 1,3 kV / - 0,9 kV / - Schutzpegel bei In Up-In 1,7 kV 1,3 kV 0,9 kV Kurzschlußfestigkeit ISCCR 25000 A 25000 A 25000 A Trennvorrichtungen Thermische Trennvorrichtung intern Vorsicherung max. 160 A (gL/gG) Fehlerstromschutzschalter Typ „S“ oder zeitverzögert Sonstige Eigenschaften Einbaumaße 1 TE, DIN 43880 Anschlußart 2,5-25 mm² (35 mm²) Statusanzeige mechanisch, Rot Ausfallverhalten Trennung vom Netz Fernmeldesignalisierung (FS) Potentialfreier Wechsler Schaltleistung max. 250 V/0,5 A (AC) / 30 V/2 A (DC) Anschlußquerschnitt FS max. 1,5 mm² ein-/mehrdrähtig Montage auf 35 mm Hutschiene Temperaturbereich -40 °C/+85 °C Schutzart IP20 Gehäusewerkstoff Thermoplastik UL-94-V0 Normen und Zulassungen Normkonform nach DIN EN61643-11, IEC 61643-11, UL 1449 ed.3 Artikel Nummer 571411 571511 571611 Zubehör Ersatzmodul - DSM130R-xxx 571400 571500 571600 * bei einpoligen Geräten ist nur CM anwendbar 18 L/N 90 9 80 L/N C 14 11 12 MI t° Ft Maßbild und Schaltbild Technische Daten DS130RS Serie Kombi-Ableiter Typ 1+2 V : Hochleistungs-Varistorblock Ft : Thermische Sicherung t° : Thermische Trennvorrichtung C : Fernsignalisierung MI : Anzeige im Fehlerfall • Kombi-Ableiter Typ 1+2 • Ableitfähigkeit pro Pol: In= 20 kA; Imax= 50kA; Iimp= 12,5 kA • Sichere Trennvorrichtung • Steckbare Schutzmodule • Fernsignalisierung serienmäßig • Erfüllt die Normen IEC 61643-11 und EN 61643-11 • Geeignet für Blitzschutzklassen III+IV nach EN 62305 DS131RS-
230
DS13 x RS - /
G
« » connection Type I «
G
» connection Type II (TT Netz) Spannungsangabe «S» Fernmeldekontakt Anzahl der geschützten Pole page 4242 Datenblatt Citel Electronics GmbH • Alleestrasse 144 • 44793 Bochum • Tel.: +49 234 / 54 72 10 • Fax: +49 234 / 54 72 199 • e-mail: info@citel.de • www.citel.de • Document could be modifi ed without noticeD171017A Artikel Bezeichnung Artikel Nr. Anschlussart Netzform Schutz Modus Imax total Iimp total Up L/PE Up L/N Up N/PE Einbaumaße DIN 43880 Schema
DS134RS
-
230
/
G
571534
230
/400 V 3-Phasen+N TT-TNS Systeme (3+1) L/N und N/PE 150 kA 50 kA 1,5 kV 1,3 kV 1,5 kV 4 TE 5
DS134RS
-120/
G
571634 120/208 V 3-Phasen+N TT-TNS Systeme (3+1) L/N und N/PE 150 kA 50 kA 1,5 kV 0,9 kV 1,5 kV 4 TE 5
DS134RS
-400 571414
230
/400 V 3-Phasen+N IT Systeme (4+0) L/PE und N/PE 200 kA 50 kA 1,7 kV - 1,7 kV 4 TE 4
DS134RS
-
230
571514
230
/400 V 3-Phasen+N TNS Systeme (4+0) L/PE und N/PE 200 kA 50 kA 1,3 kV - 1,3 kV 4 TE 4
DS134RS
-120 571614 120/208 V 3-Phasen+N TNS Systeme (4+0) L/PE und N/PE 200 kA 50 kA 0,9 kV - 0,9 kV 4 TE 4 DS133RS-400 571413 400 V 3-Phasen IT Systeme (3+0) L/PE 150 kA 37,5 kA 1,7 kV - - 3 TE 3 DS133RS-
230
571513 400 V 3-Phasen TNC Systeme (3+0) L/PE 150 kA 37,5 kA 1,3 kV - - 3 TE 3 DS133RS-120 571613 208 V 3-Phasen TNC Systeme (3+0) L/PE 150 kA 37,5 kA 0,9 kV - - 3 TE 3 DS132RS-
230
/
G
571532
230
V 1-Phase+N TT-TN Systeme (1+1) L/N und N/PE 100 kA 25 kA 1,5 kV 1,3 kV 1,5 kV 2 TE 2 DS132RS-120/
G
571632 120 V 1-Phase+N TT-TN Systeme (1+1) L/N und N/PE 100 kA 25 kA 1,5 kV 0,9 kV 1,5 kV 2 TE 2 DS132RS-400 571412
230
V 1-Phase+N IT Systeme (2+0) L/PE und N/PE 100 kA 25 kA 1,7 kV - 1,7 kV 2 TE 1 DS132RS-
230
571512
230
V 1-Phase+N TN Systeme (2+0) L/PE und N/PE 100 kA 25 kA 1,3 kV - 1,3 kV 2 TE 1 DS132RS-120 571612 120 V 1-Phase+N TN Systeme (2+0)y L/PE und N/PE 100 kA 25 kA 0,9 kV - 0,9 kV 2 TE 1 72 L2 L3 NL1 72 L2 L3 NL1 4 5 C 141112 Ft t° MI Ft t° MI C 141112 Ft t° MI Ft t° MI Ft t° MI C 141112 Ft t° MI GSG L/N L/N L N L1 L2 L3 1 2 3 C 141112 Ft t° MI Ft t° MI Ft t° MIFt t° MI C 141112 Ft t° MI Ft t° MI Ft t° MI GSG L1 L2 L3 N L1 L2 L3 N 4 5 44 74 90 9 80 54 L1 L2 L3 3636 L/N L/N L N 1 2 3 Maßbild und Schaltbild Technische Daten DS132RS, DS133RS,
DS134RS
Mehrpoliger Kombi-Ableiter Typ 1+2
DS134RS
-
230
/
G