Contact : +33 1 41 23 50 30 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
Webinars
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Search
Product Selection
DS50VGPVS-1500G-5
DS50VGPVS-1500G/51
DS50VGPVS
-G/51 products are available for PV networks with voltages of 600 V, 1000 V and 1500 Vdc. ... The
DS50VGPVS
is available with a status indicator and remote signaling.
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.
5
- Type 2 surge protector for photovoltaic - VG technology - 1500 Vdc - No leakAge, no operating currents - Improved life expectancy - In/Imax: 15 / 40 kA - Common/Differential mode protection - Remote signaling - IEC 61643-31, EN 61643-31, EN 50539-11 compliance - UL1449 ed.
5
certified
DS50VGPVS
-
1500G
/51
DS50VGPVS
DS50VGPVS
series UL Type 1 PV surge protector VG Technology Remote signaling
DSM50VGPV-
1500G
/51
DS50VGPV-1500G/51
DS50VGPV
-G/51 are type 2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. The
DS50VGPV
-G/51 SPDs incorporates CITEL's exclusive patented 'VG technology' guarantying a total absence of leakAge current and maximum reliability.
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.
5
- Type 2 surge protector for photovoltaic - VG technology - 1500 Vdc - No leakAge, no operating currents - Improved life expectancy - In/Imax : 15 / 40 kA - Common/Differential mode protection - Remote signaling (option) - IEC 61643-31, EN 61643-31, EN 50539-11 compliance - UL1449 ed.
5
certified
Option
DS50VGPVS
-
1500G
/51 - output on changeover contact
DS50VGPV
-
1500G
/51
DS50VGPV
DS50VGPV
series UL Type 1 PV surge protector VG Technology
DSM50VGPV-
1500G
/51
DP80-TW
The DP80-TW is a one-pair plug-in module that uses the
5
-pin configuration, and so can be adapted to CITEL TC99 and similar 100-pair connector block.
- Surge protector '
5
-pin' configuration - 1-pair - Fast installation with no wiring modification - Fast maintenance - For analog or high speed telecom lines
'
5
-pin' plug-in
On '
5
-pin' connector block
DP80 series Plug-in surge protector 1-pair - '
5
-pin'
DS50VGPV-1000G/51
DS50VGPV
-G/51 are type 2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. The
DS50VGPV
-G/51 SPDs incorporates CITEL's exclusive patented 'VG technology' guarantying a total absence of leakAge current and maximum reliability.
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.
5
Option
DS50VGPVS
-1000G/51 - output on changeover contact
DS50VGPV
-1000G/51
DS50VGPV
DS50VGPV
series UL Type 1 PV surge protector VG Technology
DS50VGPV-600G/51
DS50VGPV
-G/51 are type 2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. The
DS50VGPV
-G/51 SPDs incorporates CITEL's exclusive patented 'VG technology' guarantying a total absence of leakAge current and maximum reliability.
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.
5
- Type 2 surge protector for photovoltaic - VG technology - 600 Vdc - No leakAge, no operating currents - Improved life expectancy - In/Imax : 15 / 40 kA - Common/Differential mode protection - Remote signaling - IEC 61643-31, EN 61643-31, EN 50539-11, UL1449 ed.
5
compliance
Option
DS50VGPVS
-600G/51 - output on changeover contact
DS50VGPV
-600G/51
DS50VGPV
DS50VGPV
series UL Type 1 PV surge protector VG Technology
DS50VGPV-1000/12KT1
DS50VGPV
-1000/12KT1 are type 1+2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. The
DS50VGPV
-1000/12KT1 SPDs incorporates CITEL's exclusive patented 'VG technology' guarantying a total absence of leakAge current and maximum reliability.
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.
5
- Type 1+2 surge protector for Photovoltaic - VG Technology - No leakage, no operating currents - Improved life expectancy - Impulse currents Iimp/Itotal: 6.25/12.5 kA (10/350µs) - Common/Differential mode protection - Pluggable module - Remote signaling (option) - UL1449 ed.
5
compliance - IEC 61643-31, EN 61643-31 certified
Option
DS50VGPVS
-1000/12KT1 - output on changeover contact
DS50VGPV
-1000/12KT1
DS50VGPV
/12KT1
Range
DS50VGPV
/12KT1 Type 1+2 PV surge protector Pluggable modules VG Technology
DS50VGPV-1000G/12KT1
DS50VGPV
-1000G/12KT1 are type 1+2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. The
DS50VGPV
-1000G/12KT1 SPDs incorporates CITEL's exclusive patented 'VG technology' guarantying a total absence of leakAge current and maximum reliability.
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.
5
- Type 1+2 surge protector for Photovoltaic - VG Technology - No leakage, no operating currents - Improved life expectancy - Impulse currents Iimp/Itotal: 6.25/12.5 kA (10/350µs) - Common/Differential mode protection - Pluggable module - Remote signaling (option) - UL1449 ed.
5
compliance - IEC 61643-31, EN 61643-31 certified
Option
DS50VGPVS
-1000G/12KT1 - output on changeover contact
DS50VGPV
-1000G/12KT1
DS50VGPV
/12KT1
Range
DS50VGPV
/12KT1 Type 1+2 PV surge protector Pluggable modules VG Technology
DS50VGPVS-1000/12KT1
DS50VGPV
-1000/12KT1 are type 1+2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. The
DS50VGPV
-1000/12KT1 SPDs incorporates CITEL's exclusive patented 'VG technology' guarantying a total absence of leakage current and maximum reliability.
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.
5
- Type 1+2 surge protector for Photovoltaic - VG Technology - No leakage, no operating currents - Improved life expectancy - Impulse currents Iimp/Itotal: 6.25/12.5 kA (10/350µs) - Common/Differential mode protection - Pluggable module - Remote signaling - UL1449 ed.
5
compliance - IEC 61643-31, EN 61643-31 certified
DS50VGPVS
-1000/12KT1
DS50VGPV
/12KT1
Range
DS50VGPV
/12KT1 Type 1+2 PV surge protector Pluggable modules VG Technology
DS50VGPVS-1000G/12KT1
DS50VGPV
-1000G/12KT1 are type 1+2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. The
DS50VGPV
-1000G/12KT1 SPDs incorporates CITEL's exclusive patented 'VG technology' guarantying a total absence of leakAge current and maximum reliability.
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.
5
- Type 1+2 surge protector for Photovoltaic - VG Technology - No leakage, no operating currents - Improved life expectancy - Impulse currents Iimp/Itotal: 6.25/12.5 kA (10/350µs) - Common/Differential mode protection - Pluggable module - Remote signaling - IEC 61643-31, EN 61643-31, UL1449 ed.
5
compliance
DS50VGPVS
-1000G/12KT1
DS50VGPV
/12KT1
Range
DS50VGPV
/12KT1 Type 1+2 PV surge protector Pluggable modules VG Technology
MLPCA1-230L-2L
IEC 61643-11 / EN 61643-11 / UL1449 ed.
5
Cable with
5
-wire of 1.5mm²
DS50VGPVS-1000G/51
DS50VGPVS
-G/51 products are available for PV networks with voltages of 600 V, 1000 V and 1500 Vdc. ... The
DS50VGPVS
is available with a status indicator and remote signaling.
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.
5
- Type 2 surge protector for photovoltaic - VG technology - 1000 Vdc - No leakAge, no operating currents - Improved life expectancy - In/Imax : 15 / 40 kA - Common/Differential mode protection - Remote signaling - IEC 61643-31, EN 61643-31, EN 50539-11, UL1449 ed.
5
compliance
DS50VGPVS
-1000G/51
DS50VGPVS
DS50VGPVS
series UL Type 1 PV surge protector VG Technology Remote signaling
DS50VGPVS-600G/51
DS50VGPVS
-G/51 products are available for PV networks with voltages of 600 V, 1000 V and 1500 Vdc. ... The
DS50VGPVS
is available with a status indicator and remote signaling.
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.
5
- Type 2 surge protector for photovoltaic - VG technology - 600 Vdc - No leakAge, no operating currents - Improved life expectancy - In/Imax : 15 / 40 kA - Common/Differential mode protection - Remote signaling - IEC 61643-31, EN 61643-31, EN 50539-11, UL1449 ed.
5
compliance
DS50VGPVS
-600G/51
DS50VGPVS
DS50VGPVS
series UL Type 1 PV surge protector VG Technology Remote signaling
DS60VGPV-1500G/51
DS60VGPV-
1500G
/51
DACN15S-P11-150
Type 2, these products maintain a Nominal discharge current (In) of
5
kA and a Maximum discharge current (Imax) of 15 kA. According to the IEC standards, a product with an In of
5
kA can be installed in the main panel, but it can also be placed in the secondary panel, downstreaming the primary SPD.
IEC 61643-11 / EN 61643-11 / UL1449 ed.
5
- Compact single-phase Type 2 (or 3) surge protector - In :
5
kA - Imax : 15 kA - Commun/Differential mode - Monobloc module - Remote signaling - EN 61643-11, IEC 61643-11 and UL1449 ed.
5
compliance
DACN15-P11-275/INV
Type 2, these products maintain a Nominal discharge current (In) of
5
kA and a Maximum discharge current (Imax) of 15 kA. According to the IEC standards, a product with an In of
5
kA can be installed in the main panel, but it can also be placed in the secondary panel, downstreaming the primary SPD.
IEC 61643-11 / EN 61643-11 / UL1449 ed.
5
- Type 2 or 3 surge protectors with bottom connection - Compact Single-phase - In:
5
kA - Imax: 15 kA - Commun/Differential mode - Monobloc module - EN 61643-11, IEC 61643-11, and UL1449 ed.
5
compliance
DACN15S-P11-275
Type 2, these products maintain a Nominal discharge current (In) of
5
kA and a Maximum discharge current (Imax) of 15 kA. According to the IEC standards, a product with an In of
5
kA can be installed in the main panel, but it can also be placed in the secondary panel, downstreaming the primary SPD.
IEC 61643-11 / EN 61643-11 / UL1449 ed.
5
- Compact single-phase Type 2 (or 3) surge protector - In :
5
kA - Imax : 15 kA - Commun/Differential mode - Monobloc module - Remote signaling - EN 61643-11, IEC 61643-11 and UL1449 ed.
5
compliance
DAC80S-31-275
The products comply with EN 61643-11, IEC 61643-11 and UL1449 ed.
5
.
IEC 61643-11 / EN 61643-11 / UL1449 ed.
5
- Re-inforced Type 2 AC surge protector - In: 40 kA - Imax: 80 kA - Pluggable module for each phase - Remote signaling - EN 61643-11, IEC 61643-11 certified - UL1449 ed.
5
compliance
DAC80-31-150
The products comply with EN 61643-11, IEC 61643-11 and UL1449 ed.
5
.
IEC 61643-11 / EN 61643-11 / UL1449 ed.
5
- Re-inforced Type 2 AC surge protector - In : 40 kA - Imax : 80 kA - Pluggable module for each phase - Remote signaling option - EN 61643-11, IEC 61643-11 certiifed - UL1449 ed.
5
compliance
Range Selection
DS50VGPVS-1500G-5
Range DS50VGPVS - DS50VGPVS-1500G/51
Range DS50PV/51 - DS50PV-1000/51
Range DACF25 - DACF25-10-150
Range DS215 - DS215-120
Range DACF25S - DACF25S-10-150
Range DS50PVS - DS50PVS-1500/51
Range DS500E - DS500E-230
Range DUT250VG - DUT250VG-300/G
Range DS250VG - DS250VG-120
Range DAC50S - DAC50S-10-275
Range DACF15S - DACF15S-10-150
Range DAC50 - DAC50-10-320
Range DAC50VG - DAC50VG-10-150
Range DAC50VGS - DAC50VGS-10-150
Range DS50VGPV - DS50VGPV-1000G/51
Range DACF15 - DACF15-10-150
Range SFD50S - SFD50S-10-1500DC
Range DS215S - DS215S-230/G
Pages
DS50VGPVS-1500G-5
CITEL, PV surge protectors for PV power plants
| --- | --- | --- | --- | | Location | | Model | Description | | PV network | | DS60VGPV-
1500G
/51 | Type 1 + 2 Photovoltaic surge protector
Iimp 12,5 kA - VG Technology | |PV Network | |
DS50VGPVS
-1000/12KT1 | Type 1 + 2 Photovoltaic surge protector
Iimp/Itotal : 6.25 / 12.5 kA (10/350µs) - VG Technology | |AC Network | | DAC1-13S-31-275 | Type 1+2 AC surge protector
In 20 kA - Remote signaling | |DATA Network | | DLA-24D3 | 1-pair pluggable surge protector
In
5
kA - Imax 20 kA - Remote signaling | | --- | --- | |
Download flyer
|
Watch video
| | | |
SPD mandatory or not?
. SELECTION OF THE SPD Section
5
-534 of IEC 60364 «Devices for protection against overvoltages» gives the minimum performance required for SPD installed at the entrance of installation :
1 - The installation equipped with lightning rod (LPS): Recommendation : Type 1 SPD, with Lightning impulse current Iimp of 12.5 kA minimum, connected at the origin of the installation.
2 - The installation is connected to an AC network, without LPS : Recommendation : Type 2 SPD, with nominal discharge current In ≥
5
kA, connected at the origin of the installation.
CITEL, surge protectors for data center
|Position | | Description | Model | | --- | --- | ---- | --- | | 1 | | Compact Type 2 surge protector 3-phase+N |DAC40CS-31 | | 2 | | Rack 19" protection | RAK16-E-C6 | | 3 | | CAT5 - CAT6 surge protection | MJ8-C6A | | 4 | | Type 1+2+3 AC surge protector 3-phase+N | DAC1-13VGS-31 | |
5
| | 1-pair Din rail plug-in data surge protector| DLA-24D3 |
Citel, Water Waste Treatment
Implementation of coordinated system of protection against transient overvoltages |--- | --- | --- | --- | | Number | Location | Models | | 1 | AC power - Main electrical panel | DAC1-13VGS-31-275 | | | 1 | | DS254VG-300/G | | | 2 | Coaxial antenna - Radio wireless | P8AX | | | 3 | AC power - Distribution panel | DAC40CS-31-275 | | | 4 et
5
| Control circuit - Remote management | DAC15CS-31-275 | | 6 | Telecom-Data-Ethernet | DLA | | | 6 | | MJ8-POE-C6A | | | 7 | Control room | DAC50S-31-275 | | | 7 | | MJ8-POE-C6A | | | 7 | | DLA | | | --- | | Download flyer | | |
CITEL, PV surge protectors for residential installations
.
Example of a photovoltaic surge protection installation
Selection of surge protectors
| --- | --- | --- | --- | | Location | | CITEL model | Description | | AC network | | DACF15S-11-275 | Type 2 (or 3) AC surge protectors
In
5
kA - Imax 15 kA - Internal fuse - Remote signaling | |DC network | | DDC30CS-20-65 | Type 2 DC power surge protector
Imax 30 kA - Compact - Remote signaling | | --- | --- | --- | |
Download flyer
|
Watch video
|
Watch video
| | | | |
CITEL, PV surge protectors for industrial and public building
| --- | --- | --- | --- | | Location | | CITEL model | Description | | PV NETWORK | | DPVN-40CVGS-21Y-1200 | Type 2 PV surge protector
In 20kA - Imax 40kA - Remote signaling | |PV NETWORK | | DS50PVS-600/51 | Type 2 PV surge protector
In 15kA - Imax 40 kA - Remote signaling | |AC NETWORK | | DAC50S-31-275 | Type 2 AC surge protector
In 20 kA - Imax 50 kA - Remote signaling | |AC NETWORK | | DAC40CS-31-275 | Type 2 AC surge protector
In 20 kA - Imax 40 kA - Remote signaling - Compact | |DATA NETWORK | | DLA-24D3 | 1-pair pluggable surge protector
In
5
kA - Imax 20 kA - Remote signaling | | --- | --- | |
Download the flyer
|
Watch video
| | | |
PDF Found
DS50VGPVS-1500G-5
No result found