Contact : +33 1 41 23 50 30 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
Webinars
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Search
Product Selection
DS133RS-120
DS133R-120
option
DS133RS
-
120
: output on changeover contact
120
/208 V 3-phase
DS133R
-
120
DSM130R-
120
DSLP1-120L/Y
120
V single-phase or 2-phase
120
Vac withstand
MSP-VM120/R
These devices protect, in a single compact housing, all the lines connected to the system: power supply (230Vac, 24Vdc, 12Vdc or
120
Vac), dataline (6 or 8 Vdc).
120
V single-phase
MSP-VM48-RINJ
These devices protect, in a single compact housing, all the lines connected to the system: power supply (230Vac, 24Vdc, 12Vdc or
120
Vac), dataline (6 or 8 Vdc).
MSP-VM230/R
These devices protect, in a single compact housing, all the lines connected to the system: power supply (230Vac, 24Vdc, 12Vdc or
120
Vac), dataline (6 or 8 Vdc).
MSP-VM24/R
These devices protect, in a single compact housing, all the lines connected to the system: power supply (230Vac, 24Vdc, 12Vdc or
120
Vac), dataline (6 or 8 Vdc).
MSP-VM12/R
These devices protect, in a single compact housing, all the lines connected to the system: power supply (230Vac, 24Vdc, 12Vdc or
120
Vac), dataline (6 or 8 Vdc).
DU33S-1000/WD
- Type 2 AC Multipolar surge protector - In : 15 kA - Imax total :
120
kA - Remote signaling for each pole - NF EN 61643-11, IEC 61643-11 compliance
DVM-120-16A
- Protection against permanent/temporary overvoltages of AC network - For
120
Vac AC single-phase powerline - Load current: up to 16 A - Automatic operation: disconnection/reconnection - Operating indicator - Easy installation on DIN rail
120
V single-phase
DVM-
120
-16A
DS43-400
- Type 2 AC Multipolar surge protector - In : 20 kA - Imax total :
120
kA - Pluggable module for each phase - Remote signaling option - EN 61643-11, IEC 61643-11 compliance - UL1449 ed.5
DS43-480
- Type 2 AC Multipolar surge protector - In : 20 kA - Imax total :
120
kA - Pluggable module for each phase - Remote signaling option - EN 61643-11, IEC 61643-11 compliance - UL1449 ed.5
DS43-385
- Type 2 AC Multipolar surge protector - In : 20 kA - Imax total :
120
kA - Pluggable module for each phase - Remote signaling option - EN 61643-11, IEC 61643-11 compliance - UL1449 ed.5
DS43-320
- Type 2 AC Multipolar surge protector - In : 20 kA - Imax total :
120
kA - Pluggable module for each phase - Remote signaling option - EN 61643-11, IEC 61643-11 compliance - UL1449 ed.5
DS43-230
- Type 2 AC Multipolar surge protector - In : 20 kA - Imax total :
120
kA - Pluggable module for each phase - Remote signaling option - EN 61643-11, IEC 61643-11 compliance - UL1449 ed.5
DS43-120
- Type 2 AC Multipolar surge protector - In : 20 kA - Imax total :
120
kA - Pluggable module for each phase - Remote signaling option - EN 61643-11, IEC 61643-11 compliance - UL1449 ed.5
option DS43S-
120
: output on changeover contact
120
/208 V 3-phase
DS43-
120
DSM40-
120
DS43-280
- Type 2 AC Multipolar surge protector - In : 20 kA - Imax total :
120
kA - Pluggable module for each phase - Remote signaling option - EN 61643-11, IEC 61643-11 compliance - UL1449 ed.5
DS133R-230
option
DS133RS
-230 : output on changeover contact
DS133R
-230
DS133R-400
option
DS133RS
-400 : output on changeover contact
DS133R
-400
Range Selection
DS133RS-120
No result found
Pages
DS133RS-120
No result found
PDF Found
DS133RS-120
DS130RS_D171017A_DB.pdf
.: +49 234 / 54 72 10 • Fax: +49 234 / 54 72 199 • e-mail: info@citel.de • www.citel.de • Document could be modifi ed without notice Datenblatt D171017A CITEL Artikel Bezeichnung DS131RS-400 DS131RS-230 DS131RS-
120
Nennspannung Un 230/400 V 230/400 V
120
/208 V Höchste Dauerspannung AC Uc AC 440 Vac 255 Vac 150 Vac Nennfrequenz fn 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz TOV-Spannung (L-N) 5sec. ... Charakteristik UT 770 Vac /
120
min. sicher 440 Vac /
120
min. sicher 230 Vac /
120
min. sicher Schutzleiterstrom - Leckstrom (CM) bei Uc Ipe < 1 mA < 1 mA < 1 mA Folgestrom If keiner keiner keiner Folgestromlöschfähigkeit Ifi unendlich unendlich unendlich Ansprechzeit tA < 20 ns < 20 ns < 20 ns Nennableitstoßstrom / Pol 15 x 8/20 µs Impulse In 20 kA 20 kA 20 kA Max. ... Anschlussart Netzform Schutz Modus Imax total Iimp total Up L/PE Up L/N Up N/PE Einbaumaße DIN 43880 Schema DS134RS-230/G 571534 230/400 V 3-Phasen+N TT-TNS Systeme (3+1) L/N und N/PE 150 kA 50 kA 1,5 kV 1,3 kV 1,5 kV 4 TE 5 DS134RS-
120
/G 571634
120
/208 V 3-Phasen+N TT-TNS Systeme (3+1) L/N und N/PE 150 kA 50 kA 1,5 kV 0,9 kV 1,5 kV 4 TE 5 DS134RS-400 571414 230/400 V 3-Phasen+N IT Systeme (4+0) L/PE und N/PE 200 kA 50 kA 1,7 kV - 1,7 kV 4 TE 4 DS134RS-230 571514 230/400 V 3-Phasen+N TNS Systeme (4+0) L/PE und N/PE 200 kA 50 kA 1,3 kV - 1,3 kV 4 TE 4 DS134RS-
120
571614
120
/208 V 3-Phasen+N TNS Systeme (4+0) L/PE und N/PE 200 kA 50 kA 0,9 kV - 0,9 kV 4 TE 4
DS133RS
-400 571413 400 V 3-Phasen IT Systeme (3+0) L/PE 150 kA 37,5 kA 1,7 kV - - 3 TE 3
DS133RS
-230 571513 400 V 3-Phasen TNC Systeme (3+0) L/PE 150 kA 37,5 kA 1,3 kV - - 3 TE 3
DS133RS
-
120
571613 208 V 3-Phasen TNC Systeme (3+0) L/PE 150 kA 37,5 kA 0,9 kV - - 3 TE 3 DS132RS-230/G 571532 230 V 1-Phase+N TT-TN Systeme (1+1) L/N und N/PE 100 kA 25 kA 1,5 kV 1,3 kV 1,5 kV 2 TE 2 DS132RS-
120
/G 571632
120
V 1-Phase+N TT-TN Systeme (1+1) L/N und N/PE 100 kA 25 kA 1,5 kV 0,9 kV 1,5 kV 2 TE 2 DS132RS-400 571412 230 V 1-Phase+N IT Systeme (2+0) L/PE und N/PE 100 kA 25 kA 1,7 kV - 1,7 kV 2 TE 1 DS132RS-230 571512 230 V 1-Phase+N TN Systeme (2+0) L/PE und N/PE 100 kA 25 kA 1,3 kV - 1,3 kV 2 TE 1 DS132RS-
120
571612
120
V 1-Phase+N TN Systeme (2+0)y L/PE und N/PE 100 kA 25 kA 0,9 kV - 0,9 kV 2 TE 1 72 L2 L3 NL1 72 L2 L3 NL1 4 5 C 141112 Ft t° MI Ft t° MI C 141112 Ft t° MI Ft t° MI Ft t° MI C 141112 Ft t° MI GSG L/N L/N L N L1 L2 L3 1 2 3 C 141112 Ft t° MI Ft t° MI Ft t° MIFt t° MI C 141112 Ft t° MI Ft t° MI Ft t° MI GSG L1 L2 L3 N L1 L2 L3 N 4 5 44 74 90 9 80 54 L1 L2 L3 3636 L/N L/N L N 1 2 3 Maßbild und Schaltbild Technische Daten DS132RS,
DS133RS