Type 1+2+3 AC surge protector - 3-phase+N

DS134VGS-120
Part Number 571674
DS134VGS-120
  • Discover our latest innovation : the DAC1-13VGS-40-150
  • Type 1 + 2 + 3 AC surge protector
  • In : 20 kA
  • Iimp total : 50 kA on 10/350µs impulse
  • Pluggable module
  • Optimized to TOV
  • Remote signaling
  • EN 61643-11, IEC 61643-11 and UL1449 ed.5 compliance

The DS130VG is an extreme duty Type 1+2+3 AC surge protector device designed to protect at the entrance of the electrical installation. This SPD is particularly useful in a high lightning density area where the risk of heavy surge current or even direct strike is high (eg: buildings equipped with lightning rods). The DS130VG is one-pole SPD and can be used in common mode or common and differential mode. DS130VG AC surge protectors are designed to be connected in multi-pole configuration to protect single-phase, 3-phase and 3-phase+Neutral AC networks, sometimes associated with a dedicated N/PE SPD.

Select another reference:

SPD type
IEC 1+2+3
Network
120/208 V 3-phase+N
AC system
TNS
Nominal line voltage
Un 120 Vac
Max. AC operating voltage
Uc 150 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT 180 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT 230 Vac withstand
Residual Current
Leakage current to Ground
Ipe None
Operating current
Continious current at Uc
Ic None
Follow current
If None
Nominal discharge current
15 x 8/20 µs impulses
In 20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax 50 kA
Impulse current by pole
max. withstand 10/350µs by pole
Iimp 12.5 kA
Total lightning current
max. total withstand @ 10/350µs
Itotal 50 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc 20 kV
Withstand on overvoltages IEEE C62.41.1
20 kV
Specific energy by pole
max. withstand 10/350 µs
W/R 40 kJ/ohm
Connection mode(s)
L/PE and N/PE
Protection mode(s)
Common mode
Residual voltage
@ In (8/20 µs)
Up-in 0.4 kV
Protection level N/PE
@ In (8/20µs)
Up N/PE 1.25 kV
Protection level L/PE
@ In (8/20µs)
Up L/PE 1.25 kV
Admissible short-circuit current
Isccr 25 000 A
Technology
VG Technology (MOV+GSG)
SPD configuration
3-phase+Neutral
Connection to Network
By screw terminals: 2.5-25mm² / by bus
Format
Plug-in modular box
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu -40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole
Spare module(s)
DSM130VG-120
Remote signaling of disconnection
Output on changeover contact
Dimensions
See diagram
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
UL Recognized
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
Fuses Type gG - 125 A