Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Se connecter
Créer un compte
Vente en ligne réservée à la France
Gammes de parafoudres
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Search
Sélection de produits
CNP06-B-MM
CNP06 B/FM
CNP06
B
/FM
CNP06-B/MF
CNP06
-
B
/MF
DSDT16
The DSDT16 is a terminal adapter that transforms a screw terminal into a double terminal to connect an incoming and an outgoing cable, with a maximum section of 35
mm
² per conductor.
- 'V' connection screw terminal for SPD - Improved connection for better efficiency - 2 x 25
mm
² wire connection - Adapted to DAC/DDC surge protectors - UL486A/
B
(CAN/CSA-C22.2) certified to 40A - IEC 60947-7-1 tested to 100A
2.5 - 25
mm
² (12-4 AWG), solid, stranded & flexible
DDT16
The DDT16 is a terminal adapter that transforms a screw terminal into a double terminal to connect an incoming and an outgoing cable, with a maximum section of 35
mm
² per conductor.
- 'V' connection screw terminal for SPD - Improved connection for better efficiency - 2 x 35
mm
² wire connection - Adapted to DAC/DDC surge protectors
2.5 - 25
mm
² (12-4 AWG), solid, stranded & flexible
ZPAC1-8VG-31-275
- Type 1+2+3 AC Surge protection - VG Technology - For 40
mm
busbar systems - Iimp 8 kA (10/350 μs) - Reduces energy costs: Does not produce flow current and leakage current - Certified IEC 61643-11 and EN 61643-11
40
mm
busbar systems
ZPAC Series Combined SPD Type 1+2+3 For 40
mm
Busbar based on "VG-Technology"
PCH12-POE-B
- 19'' patch panel surge protector for POE-
B
- 12 ports - In : connector type 110 back - Out : RJ45 front - Maintenance possible per port - Secondary protection - UL497B
19'' patch panel surge protector - POE-
B
line
POE mode
B
, Gigabit Ethernet, POE Plus
PCH12-POE-
B
PCH24-POE-B
- 19'' patch panel surge protector for POE-
B
- 24 ports - In : connector type 110 back - Out : RJ45 front - Maintenance possible per port - Secondary protection - UL497B
19'' patch panel surge protector - POE-
B
line
POE mode
B
, Gigabit Ethernet, POE Plus
PCH24-POE-
B
PCH48-POE-B
- 19'' patch panel surge protector for POE-
B
- 48 ports - In : connector type 110 back - Out : RJ45 front - Maintenance possible per port - Secondary protection - UL497B
19'' patch panel surge protector - POE-
B
line
POE mode
B
, Gigabit Ethernet, POE Plus
PCH48-POE-
B
SFD1-25
22x58
mm
SFD1-13
14x51
mm
PAC40S-10-275
18
mm
PAC40S-10-680
18
mm
PAC40S-10-420
18
mm
PAC25S-10-680
18
mm
PAC25S-10-150
9.6
mm
PAC25S-10-275
9.6
mm
PAC25S-10-420
9.6
mm
CNP06 F/MF
CNP06
F/MF
Sélection de gammes
CNP06-B-MM
Range B480 - B480-06D3
Range B280 - B280-06D3
Range B180 - B180-06D3
Pages
CNP06-B-MM
Technical note: PPV-PAC series
With a width of just 9
mm
(0.5 TE) per pole for type 2 arrestors (SPD T2) up to powerful T1+T2 combined arrestors with a width of only 22
mm
(1.25 TE), the PPV arrestors can be accommodated even in the smallest spaces.
International Standards
The phenomena were first characterized and a series of standardized waves created (1.2/50µs voltage wave and 8/20µs and 10/350µs current waveforms), then a number of standards defining surge arrester performance were issued, among them : Surge Protectors for Low-Voltage installations: - NF EN 61643-11 (France) - VDE 0675-6-11 (Germany) - EN 61643-11 (Europe) - UL1449 (USA) - IEC 61643-11 (International) Surge Protectors for Telecom equipment: - IEC 61643-21 (International) - ITU-T recommendations K11, K12, K17, K20, K21, K36 (International) - UL 497 A/
B
(USA)
SPD mandatory or not?
Protection against transient overvoltage shall be provided where the consequence caused by overvoltage affects:
a) human life, e.g. safety services, medical care facilities;
b
) public services and cultural heritage, e.g. loss of public services, IT centres, museums;
c) commercial or industrial activity, e.g. hotels, banks, industries, commercial markets, farms.
CITEL, surge protectors for security systems
. Selection of SPDs for Security Systems 1 - Surge Protectors for Survey Cameras | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Anolog Camera | MSP-VM230-2P | Combined surge protectors | | | IP Cameras | LAN-10G-POE-CR | Outdoor POE++ and 10 Gigabit Ethernet | | | Coaxial lines as Video-transmission | CXC06-
B
/FM | Coaxial surge protector, BNC connector | | | 10Gigabit Ethernet/POE++ networks | MJ8-POE-C6A | Ethernet surge protector, Shielded RJ45 connections on Cat6A cabling | | | 10Gigabit Ethernet | MJ8-C6A | Ethernet surge protector, Shielded RJ45 connections on Cat6A cabling | |
2 - Surge Protectors for Control Rooms | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Control room | RAK16-E-C6 | 19" Rack surge protector - 10/100/1000BaseT networks | |
3 - Surge Protectors for Main Electrical Panel | Location | Citel models | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | AC network - Main switchboard | DAC1-13S-31-275 | Type 1+2+3 surge protector 3-phase+N | |
4 - Surge Protectors for fire Alarm | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Fire alarm | DAC40CS-11-275 | Type 2 (or 3) surge protector - Compact - Single phase | | | Fire alarm | DAC40CS-31-275 | Type 2 (or 3) surge protector - Compact - 3-phase | |
5 - Surge Protector for Acces Control | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Access control | DLA | Dataline surge protectors - DIN rail mounting | |
6 - Surge Protector for LED Lighting | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Inside the cutouts of led lighting pole | DLPM1-230L | 230 V single phase surge protector - DIN rail mounting | |
| --- | --- | |
Download flyer
|
Watch video
| | | |
Privacy Policy
A - Purposes The main purposes of CITEL collecting personal data on its website can be summarised as follows: - to contact us via the form and enable us to respond to you and to ensure a commercial or informative follow-up.
B
- Data storage period The personal data collected on the site is only retained for the period strictly necessary with regard to the purposes set out above, i.e. 3 years from our last exchange.
PDF Found
CNP06-B-MM
Aucun résultat trouvé