Contact : +33 1 41 23 50 30 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
Webinars
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Search
Product Selection
CNP06-B-MF
CNP06-B/MF
CNP06
-
B
/
MF
CNP06 B/FM
CNP06
B
/FM
CNP06 F/MF
CNP06
F/
MF
CXC06-B/MF
CXC06-
B
/
MF
P8AX25-B/MF
P8AX25-
B
/
MF
MJ8-POE-IT
IEC 61643-21 / EN 61643-21 / UL497
B
/ IEEE 802-3ab/3at
RJ45 surge protector for POE-
B
POE-
B
and Gigabit Ethernet, High POE
CMJ8-POE-B-C5E
- <
b
>Discover our latest innovation : the
CWMJ8-POE-C6A
b
> - POE ++ compatible surge protector - Category 5E compatible - Shielded RJ45 connectors - Outdoor application: IP67 - Metal enclosure - Compliant with IEC 61643-21, NF EN 61643-21 - UL497B certified
Outdoor gigabit POE-
B
surge protector
POE-
B
and Gigabit Ethernet, High POE
CMJ8-POE-
B
-C5E
CNP06 F/FF
CNP06
F/FF
PCH12-POE-B
- 19'' patch panel surge protector for POE-
B
- 12 ports - In : connector type 110 back - Out : RJ45 front - Maintenance possible per port - Secondary protection - UL497B
19'' patch panel surge protector - POE-
B
line
POE mode
B
, Gigabit Ethernet, POE Plus
PCH12-POE-
B
PCH48-POE-B
- 19'' patch panel surge protector for POE-
B
- 48 ports - In : connector type 110 back - Out : RJ45 front - Maintenance possible per port - Secondary protection - UL497B
19'' patch panel surge protector - POE-
B
line
POE mode
B
, Gigabit Ethernet, POE Plus
PCH48-POE-
B
PCH24-POE-B
- 19'' patch panel surge protector for POE-
B
- 24 ports - In : connector type 110 back - Out : RJ45 front - Maintenance possible per port - Secondary protection - UL497B
19'' patch panel surge protector - POE-
B
line
POE mode
B
, Gigabit Ethernet, POE Plus
PCH24-POE-
B
PL12-CAT6
IEC 61643-21 / EN 61643-21 / UL497
B
/ IEEE 802-3an
PL24-CAT6
IEC 61643-21 / EN 61643-21 / UL497
B
/ IEEE 802-3an
MJ8-POE-B
IEC 61643-21 / EN 61643-21 / UL497
B
/ IEEE 802-3ab/3at
- <
b
>Discover our latest innovation : the
MJ8-POE-C6A
b
> - POE++ compatible - Gigabit Ethernet (Cat.5E) - Shielded enclosure and connectors - 2 kA discharge capability - UL497B certified - IEC 61643-21, EN 61643-21 compliance
POE-
B
and Gigabit Ethernet, High POE
MJ8-POE-
B
CXC06-B/FM
CXC06-
B
/FM
P8AX25-B/FF
P8AX25-
B
/FF
PRC2100-N/MF
PRC2100-N/
MF
PRC900-716/MF
PRC900-716/
MF
Range Selection
CNP06-B-MF
Range B480 - B480-06D3
Range B280 - B280-06D3
Range MSB6 - MSB6-24/LD
Range B180 - B180-06D3
Range MSB10 - MSB10-120(UL)
Range BN - BN16-V
Range BF P - BF P100 230/20
Pages
CNP06-B-MF
Citel, surge protection for radiocom site
. Selection of SPDs |Position | | Description | Model | | --- | --- | ---- | --- | | 1 | | 'Quarter Wave' Coaxial SPD type 7/16 |PRC1800-716/
MF
| | 2 | | Type 1 and Type 2 DC surge protector | DS252C-48DC/G | | 3 | | 3-phase+N Type 1+2 AC surge protector | DAC1-13S-31-275 | | 3 | | Type 1+2+3 AC surge protector | DS254VG-300/G | | 4 | | 1-pair Data surge protector | DLA-24D3 | | --- | |
Watch video
| | |
International Standards
The phenomena were first characterized and a series of standardized waves created (1.2/50µs voltage wave and 8/20µs and 10/350µs current waveforms), then a number of standards defining surge arrester performance were issued, among them : Surge Protectors for Low-Voltage installations: - NF EN 61643-11 (France) - VDE 0675-6-11 (Germany) - EN 61643-11 (Europe) - UL1449 (USA) - IEC 61643-11 (International) Surge Protectors for Telecom equipment: - IEC 61643-21 (International) - ITU-T recommendations K11, K12, K17, K20, K21, K36 (International) - UL 497 A/
B
(USA)
SPD mandatory or not?
Protection against transient overvoltage shall be provided where the consequence caused by overvoltage affects:
a) human life, e.g. safety services, medical care facilities;
b
) public services and cultural heritage, e.g. loss of public services, IT centres, museums;
c) commercial or industrial activity, e.g. hotels, banks, industries, commercial markets, farms.
CITEL, surge protectors for security systems
. Selection of SPDs for Security Systems 1 - Surge Protectors for Survey Cameras | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Anolog Camera | MSP-VM230-2P | Combined surge protectors | | | IP Cameras | CRMJ8-POE-C6A | POE++ and 10 Gigabit Ethernet | | | Coaxial lines as Video-transmission | CXC06-
B
/FM | Coaxial surge protector, BNC connector | | | 10Gigabit Ethernet/POE++ networks | MJ8-POE-C6A | Ethernet surge protector, Shielded RJ45 connections on Cat6A cabling | | | 10Gigabit Ethernet | MJ8-C6A | Ethernet surge protector, Shielded RJ45 connections on Cat6A cabling | |
2 - Surge Protectors for Control Rooms | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Control room | RAK16-E-C6 | 19" Rack surge protector - 10/100/1000BaseT networks | |
3 - Surge Protectors for Main Electrical Panel | Location | Citel models | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | AC network - Main switchboard | DAC1-13S-31-275 | Type 1+2+3 surge protector 3-phase+N | |
4 - Surge Protectors for fire Alarm | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Fire alarm | DAC40CS-11-275 | Type 2 (or 3) surge protector - Compact - Single phase | | | Fire alarm | DAC40CS-31-275 | Type 2 (or 3) surge protector - Compact - 3-phase | |
5 - Surge Protector for Acces Control | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Access control | DLA | Dataline surge protectors - DIN rail mounting | |
6 - Surge Protector for LED Lighting | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Inside the cutouts of led lighting pole | DLPM1-230L | 230 V single phase surge protector - DIN rail mounting | |
| --- | --- | |
Download flyer
|
Watch video
| | | |
Privacy Policy
A - Purposes The main purposes of CITEL collecting personal data on its website can be summarised as follows: - to contact us via the form and enable us to respond to you and to ensure a commercial or informative follow-up.
B
- Data storage period The personal data collected on the site is only retained for the period strictly necessary with regard to the purposes set out above, i.e. 3 years from our last exchange.
PDF Found
CNP06-B-MF
CNP06__F_F130411B.pdf
.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail: contact@citel.fr.com • www.citel.fr
CNP06
-
B
/FM o m a _ ` m F F F 24 61 43 32 48F Fiche Technique Parafoudre coaxial pour vidéotransmission Gamme
CNP06
Caractéristiques F130411B • Document sujet à modification sans préavis P : Eclateur à gaz bipolaire DBC : Diode basse capacité R : Résistance • Parafoudres coaxiaux • Connectiques BNC ou F • Faibles pertes d’insertion • Mise en oeuvre instantanée • Conforme CEI 61643-21, NF EN 61643-21 et UL497C/E Référence CITEL
CNP06
* Description Parafoudre Coaxial pour réseaux informatiques vidéotransmission Technologie Eclateur à gaz + Diode Bande passante f DC-100 MHz Puissance maximale P 4 W Impédance Z 50/75 ohms Perte d’insertion - @ fmax ≤ 0.5 dB Return Loss ≥20 dB TOS (VSWR) < 1.3:1 Courant max de ligne IL 0.5 A Courant de décharge nominal - Test 8/20µs x 10 - catégorie C2 In 5 kA Courant de décharge maximal - tenue max. 8/20 µs Imax 20 kA Courant de choc - Test 10/350µs x 2 - catégorie D1 Iimp 2.5 kA Niveau de protection Up 20 V Mise hors service de sécurité court-circuit Caractéristiques mécaniques Dimensions voir schéma Raccordement au réseau Connecteur BNC ou F Indication de mise hors service interruption de transmission Montage sur platine Température de fonctionnement -40/+85°C Indice de protection IP20 Boîtier Métal+plastic Conformité aux normes CEI 61643-21 / NF EN 61643-21 / UL497C / UL497E Référence / Code Article connectique BNC Femelle/Mâle
CNP06
-
B
/FM 64270 connectique BNC Mâle/Femelle
CNP06
-
B
/
MF
632611 connectique F Femelle/Femelle
CNP06
-F/FF 632602 connectique F Mâle/Femelle
CNP06
-F/
MF
632601
CNP06__E_F130412B.pdf
.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail: contact@citel.fr.com • www.citel.fr
CNP06
-
B
/FM o m a _ ` m F F F 24 61 43 32 48F Ficha Técnica Características F130412B • Reservado el derecho a modificaciones de este documento Protección coaxial para redes informáticas, video, transmisión Gama
CNP06
P : Descargador de gas bipolar DBC : Diodo baja capacidad R : Resistor • Protecciones coaxiales • Conectores BNC o F • Perdidas de inserción limitadas • Aplicación instantánea • Conforme a la IEC 61643-21, EN 61643-21 y UL497C/E Referencias CITEL
CNP06
* Designación Protección coaxial para redes informáticas, video-transmisión Tecnología GDT + Diodo Frecuencia máx. f DC - 100 MHz Potencia máx. P 4 W Impedancia Z 50/75 ohms Perdida de inserción ≤0.5 dB Return loss >20 dB VSWR - ROE < 1.3:1 Corriente máx. de línea IL 0.5 A Corriente de descarga nominal - Prueba 8/20µs x 10 - C2 Categoria In 5 kA Corriente de descarga máxima - 1 impulso 8/20µs Imax 20 kA Corriente de choque - Prueba 10/350µs x 2 - categoria D1 Iimp 2.5 kA Nivel de protección Up 20 V Final de vida corto-circuito Características mecánicas Dimensiones ver esquema Conexión a la red Conector BNC o F Indicador de desconexión interrupción de transmisión Montaje sobre pletina Temperatura de operación -40/+85°C Clase de protección IP20 Material de la caja Metal+plástico Conformidad con las normas IEC 61643-21 / EN 61643-21 / UL497C / UL497E Código Conector BNC hembra/macho
CNP06
-
B
/FM 64270 Conector BNC macho/hembra
CNP06
-
B
/
MF
632611 Conector F hembra/hembra
CNP06
-F/FF 632602 Conector F macho/hembra
CNP06
-F/
MF
632601
CNP06__A_F99712L.pdf
.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail: contact@citel.fr.com • www.citel.fr
CNP06
-
B
/FM o m a _ ` m F F F 24 61 43 32 48F Data Sheet Characteristics F99712L • Document could be modified without notice Coaxial surge protector for video transmission networks
CNP06
series P : 2-electrode gas tube DBC : Low capacitance diode R : Resistor • Coaxial surge protector • BNC or F connectors • Low insertion loss • Easy installation • IEC 61643-21, EN 61643-21 and UL497C/E CITEL Model
CNP06
* Description Coaxial surge protector for video transmission networks Technology GDT + Diode Max. frequency f DC - 100 MHz Max Power P 4 W Impedance Z 50/75 ohms Insertion loss ≤ 0.5 dB Return loss >20 dB VSWR < 1.3:1 Max. Load current IL 0.5 A Nominal discharge current - 8/20µs Test x 10 - C2 Category In 5 kA Max. discharge current -max. withstand @ 8/20 µs by pole Imax 20 kA Impulse current - 2 x 10/350µs Test - D1 Category Iimp 2.5 kA Protection level Up 20 V Failsafe behavior short-circuit Mechnical characteristics Dimensions see diagram Connection to Network BNC or F connector Disconnection indicator transmission interrupt Mounting on plate Operating temperature -40/+85°C Protection rating IP20 Housing material Metal+plastic Standards compliance IEC 61643-21 / EN 61643-21 / UL497C / UL497E Part number BNC connector Female/Male
CNP06
-
B
/FM 64270 BNC connector Male/Female
CNP06
-
B
/
MF
632611 F connector Female/Female
CNP06
-F/FF 632602 F connector F Male/Female
CNP06
-F/
MF
632601