Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 1+2 AC surge protector
DAC1-13S-10-320
Type 1+2 AC surge protector - 1-pole
DAC1-13S-10-320
Part Number
821710321
Type 1 + 2 AC surge protector
In : 20 kA
Iimp : 12.5 kA
Pluggable module for each phase
Remote signaling
EN 61643-11, IEC 61643-11 certified
UL1449 ed.5 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
The DAC1-13 is an extreme duty Type 1+2 pluggable SPD designed to protect AC powerline at the main switchboard of an installation equipped with lightning rod. The technology ‘Multi-varistor” allows a very high discharge current capability in small dimensions and the best possible behavior to the AC network (no follow current). In the light of their high discharge capability, the DAC1-13 surge protectors are especially compact and are available in multipolar versions to protect single or 3-phase AC networks.
Select another reference:
DAC1-13S-10-150
DAC1-13S-10-275
DAC1-13S-10-320
DAC1-13S-10-440
DAC1-13S-11-150
DAC1-13S-11-275
DAC1-13S-11-320
DAC1-13S-20-150
DAC1-13S-20-275
DAC1-13S-20-320
DAC1-13S-20-440
DAC1-13S-30-150
DAC1-13S-30-275
DAC1-13S-30-320
DAC1-13S-30-440
DAC1-13S-31-150
DAC1-13S-31-275
DAC1-13S-31-320
DAC1-13S-40-150
DAC1-13S-40-275
DAC1-13S-40-320
DAC1-13S-40-440
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
1+2
Max. AC operating voltage
Uc
320 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac disconnection
Residual Current
Leakage current to Ground
Ipe
< 1 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
50 kA
Impulse current by pole
max. withstand 10/350µs by pole
Iimp
12.5 kA
Specific energy by pole
max. withstand 10/350 µs
W/R
40 kJ/ohm
Protection level
@ In (8/20µs)
Up
1.6 kV
Residual voltage at 5 kA
@ 5 kA (8/20µs)
Up-5kA
1.2 kV
Admissible short-circuit current
Isccr
50 000 A
Network type
AC
Technology
MOV
SPD configuration
Single phase
Connection to Network
By screw terminals: 2.5-25mm² (35mm² rigid)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator - Red/Green
Spare module(s)
MDAC1-13-320
Remote signaling of disconnection
Output on changeover contact
Wiring for remote signaling
1.5 mm² max.
Max. Voltage/Current for remote signaling
250 V / 0.5 A (AC) / 30 V / 3 A (DC)
Dimensions
See diagram - 1TE (EN43880)
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
KEMA
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
315 A max. - Fuses Type gG / or SFD1-25S
×
Description:
Type 1+2 AC surge protector - 1-pole
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
KEMA / EAC
Technology:
MOV
SPD configuration:
Single phase
Remote signaling of disconnection:
Output on changeover contact
SPD type :
1+2
Max. AC operating voltage :
320 Vac
Residual Current :
< 1 mA
Max. discharge current :
50 kA
Impulse current by pole :
12.5 kA
Protection level :
1.6 kV
Admissible short-circuit current:
50 000 A
CITEL
Reference:
DAC1-13S-10-320
Part Number:
821710321
Or equivalent