Contact : 01 41 23 50 35 (9h - 17h)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
Citel's VG Technology
SPD mandatory or not?
GDT overview
New range SPDs AC-DC
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
GDT
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic Photovoltaic
Industry Photovoltaic
Solar Farms
Energy storage sytems
Water Treatment
Services
Downloading
Webinars
partnership
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Wind Turbine
GDT
Accessories
AC Power
Type 2 (or 3) AC surge protector
DS98-24
Compact single-phase type 2 (or 3) surge protector - 24 V - Monobloc
DS98-24
Part Number:
350904
Compact single-phase surge protector type 2 (or 3)
Safety disconnection in-line
Double connection in series
Remote signaling
Common and differential mode
Monobloc and economic
Datasheet
Installation Sheet
Tender specifications
Contact Us
DS98-24 surge protector is used for the 'secondary' protection of the 24 V networks against the surge voltages creating by lightning. DS98 is equipped with safety disconnection, indicator and remote signal. The disconnection will be indicate by the turn on of the red led in the front. Very compact, the DS98-24 surge protector must be installed close by the equipment to protect, downstream a 'primary' surge protector. DS98 provides both a common and differential mode protection.
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2 (or 3)
Network
24 V single-phase
Nominal line voltage
Un
24 Vac
Max. AC operating voltage
Uc
28 Vac
Max. load current
IL
16 A
Residual Current
Ipe
None
Follow current
If
None
Nominal discharge current
In
1.5 kA
Max. discharge current
Imax
3 kA
Withstand on Combination waveform IEC 61643-11
Uoc
3 kV
Withstand on overvoltages IEEE C62.41.1
3 kV
Protection mode(s)
Common/Differential mode
Protection level L/N
Up L/N
220 V
Protection level N/PE
Up N/PE
650 V
Admissible short-circuit current
Isccr
10 000 A
SPD configuration
Single phase
Connection to Network
By screw terminals: 2.5mm² max.
Format
Monobloc modular box
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Outdoor application
No
Failsafe mode
Disconnection from AC network
Disconnection indicator
Red light on
Remote signaling of disconnection
Contact NF open
Dimensions
See diagram
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
EAC
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Fuses
Fuses type gG - 20A
×