Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 2 DC surge protector
DDCN03S-21YG-30
Compact Type 2 (or 3) DC surge protector - 30 V - Monobloc
DDCN03S-21YG-30
Part Number
70124042
DC Power Type 2 (or 3) SPD
2-port configuration (series mounting)
Compact and Cost effective
In/Imax: 1.5 kA/ 3 kA
Max. load current: 25A
Disconnection
Remote signaling
EN 61643-11, IEC 61643-11 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
The devices of the DDCN series are SPDs of type 2+3 and designed for use in applications with nominal voltages of 24 or 48 Vdc, such as sensitive sensors, control systems in industry, etc.. The DDCN can be used as 1-port or 2-port SPD. The generously dimensioned connection cage with its capacity for cable cross-sections of up to 10 mm² ensures practical installation. The 2-pole DC surge arresters are designed for DIN rail mounting and occupy only 1 HP. The certification as type 2 + 3 was based on tests with similar parameters, which are also used for AC SPDs, but also according to the draft of P DIN IEC 61643-41 "Surge protective devices for use in low-voltage DC installations - Requirements and tests".
Select another reference:
DDCN03S-21YG-30
DDCN03S-L21YG-30
DDCN06S-21YG-65
DDCN06S-L21YG-65
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
Nominal DC voltage
Un-dc
24 Vdc
Max. DC operating voltage
Uc
30 Vdc
Max. load current
@25°C
IL
25 A
Residual Current
Leakage current to Ground
Ipe
None
Nominal discharge current
15 x 8/20 µs impulses
In
1.5 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
3 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
3 kV
Connection mode(s)
+/-/PE
Protection level +/-
@ In (8/20µs)
Up
0.2 kV
Protection level +/PE (-/PE)
@ In (8/20µs)
Up
0.8 kV
Admissible short-circuit current
Isccr
10 000 A
Network type
DC
Connection to Network
By screw terminals: 1.5-10mm²
Plugable
No
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Outdoor application
No
Failsafe mode
Disconnection from DC network
Disconnection indicator
Green LED OFF
Remote signaling of disconnection
output on NC contact
Dimensions
See diagram - 1TE (EN43880)
Weight
0.089 kg
Standards compliance
IEC 61643-11 / prIEC 61643-41
Thermal disconnector
Internal
Back-up protection device
Fuses type gG - 25A
×
Description:
Compact Type 2 (or 3) DC surge protector - 30 V - Monobloc
Standards compliance:
IEC 61643-11 / prIEC 61643-41
Remote signaling of disconnection:
output on NC contact
Max. DC operating voltage:
30 Vdc
Residual Current :
None
Max. discharge current :
3 kA
Admissible short-circuit current:
10 000 A
CITEL
Reference:
DDCN03S-21YG-30
Part Number:
70124042
Or equivalent