Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Search
Product Selection
mj8
MJ8-CAT6S
The
MJ8
-CAT6s surge protector is designed to protect data processing equipment, connected to twisted pair Ethernet 10 to 1000 Mbit/s network Featured with in/out shielded RJ45 connectors.
-
Discover our latest innovation : the
MJ8
-C6A
- CAT6 networks surge protector - 10/100/1000 compatible - RJ45 connector - Shielded enclosure - Bi-directional
MJ8
-CAT6S
MJ8
MJ8
Series Ethernet surge protectors UL497B CAT6A, CAT6, CAT5e, CAT5 Compatible
MJ8-CAT5E
The
MJ8
-CAT5E surge protector is designed to protect data processing equipment, connected to twisted pair Ethernet 10 to 1000 Mbit/s network Featured with in/out shielded RJ45 connectors.
-
Discover our latest innovation : the
MJ8
-C6A
- CAT5 networks surge protector - 10/100/1000BaseT compatible - RJ45 connector - Shielded enclosure - Bi-directional - UL497B certified
MJ8
-CAT5E
MJ8
MJ8
Series Ethernet surge protectors UL497B CAT6A, CAT6, CAT5e, CAT5 Compatible
MJ8-C6A
The
MJ8
-C6A surge protector is designed to protect data processing equipment, connected to twisted pair Ethernet 10 to 10Gbit/s network Featured with in/out RJ45 connectors.
MJ8
-C6A
MJ8
MJ8
Series Ethernet surge protectors UL497B CAT6A, CAT6, CAT5e, CAT5 Compatible
MJ8-POE-A
The
MJ8
-POE is designed to protect sensitive data-processing equipment connected to a POE++ (Power over Ethernet) network from transient overvoltages. The
MJ8
-POE surge protector is deployed in signal network applications with data transmission speeds of 100 and 1000 Mbps.
MJ8
-POE-A
MJ8
-POE
MJ8
-POE Series for IEEE 802.3af, 802.3at, 802.3btUL497BCAT6A,CAT6, CAT5e, CAT5
MJ8-ISDN
The
MJ8
-ISDN surge protector is designed to protect sensitive telecom terminals against lightning surges.
MJ8
-ISDN
MJ8
-Telecom
MJ8
Data series Telecom surge protector UL497B 12V to 170V DC
MJ8-170V
The
MJ8
-170V surge protector is designed to protect sensitive telecom terminals against lightning surges.
MJ8
-170V
MJ8
-Telecom
MJ8
Data series Telecom surge protector UL497B 12V to 170V DC
MJ8-POE-C6A
The
MJ8
-POE-C6A is designed to protect sensitive data-processing equipment connected to a POE++ (Power over Ethernet) network from transient overvoltages. ... The
MJ8
-POE-C6A surge protector is deployed in signal network applications with data transmission speeds up to 10 GMbps.
MJ8
-POE-C6A
MJ8
-POE
MJ8
-POE Series for IEEE 802.3af, 802.3at, 802.3btUL497BCAT6A,CAT6, CAT5e, CAT5
MJ8-POE-A/SD
MJ8
-POE-A/SD is designed with more stronger mounting DIN-Rail bracket for fitting vibration environment like wind turbines.
MJ8
-POE-A/SD
MJ8
-POE-A/SD
MJ8
-POE-A/SD Series POE++ Surge protector Gigabit Ethernet (Cat.5E)
CWMJ8-POE-C6A
It completes the existing range of CITEL PoE surge protectors (CRMJ8-POE-C6A with metal enclosure, for outdoor application &
MJ8
-POE-C6A for indoor use).
Range Selection
mj8
Range MJ8 - MJ8-C6A
Range MJ8-Telecom - MJ8-170V
Range MJ8-POE - MJ8-POE-A
Range MJ8-POE-A/SD - MJ8-POE-A/SD
Pages
mj8
Citel, Water Waste Treatment
Implementation of coordinated system of protection against transient overvoltages |--- | --- | --- | --- | | Number | Location | Models | | 1 | AC power - Main electrical panel | DAC1-13VGS-31-275 | | | 1 | | DS254VG-300/G | | | 2 | Coaxial antenna - Radio wireless | P8AX | | | 3 | AC power - Distribution panel | DAC40CS-31-275 | | | 4 et 5 | Control circuit - Remote management | DAC15CS-31-275 | | 6 | Telecom-Data-Ethernet | DLA | | | 6 | |
MJ8
-POE-C6A | | | 7 | Control room | DAC50S-31-275 | | | 7 | |
MJ8
-POE-C6A | | | 7 | | DLA | | | --- | | Download flyer | | |
CITEL, surge protectors for data center
|Position | | Description | Model | | --- | --- | ---- | --- | | 1 | | Compact Type 2 surge protector 3-phase+N |DAC40CS-31 | | 2 | | Rack 19" protection | RAK16-E-C6 | | 3 | | CAT5 - CAT6 surge protection |
MJ8
-C6A | | 4 | | Type 1+2+3 AC surge protector 3-phase+N | DAC1-13VGS-31 | | 5 | | 1-pair Din rail plug-in data surge protector| DLA-24D3 |
CITEL, surge protectors for security systems
. Selection of SPDs for Security Systems 1 - Surge Protectors for Survey Cameras | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Anolog Camera | MSP-VM230-2P | Combined surge protectors | | | IP Cameras | CRMJ8-POE-C6A | POE++ and 10 Gigabit Ethernet | | | Coaxial lines as Video-transmission | CXC06-B/FM | Coaxial surge protector, BNC connector | | | 10Gigabit Ethernet/POE++ networks |
MJ8
-POE-C6A | Ethernet surge protector, Shielded RJ45 connections on Cat6A cabling | | | 10Gigabit Ethernet |
MJ8
-C6A | Ethernet surge protector, Shielded RJ45 connections on Cat6A cabling | |
2 - Surge Protectors for Control Rooms | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Control room | RAK16-E-C6 | 19" Rack surge protector - 10/100/1000BaseT networks | |
3 - Surge Protectors for Main Electrical Panel | Location | Citel models | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | AC network - Main switchboard | DAC1-13S-31-275 | Type 1+2+3 surge protector 3-phase+N | |
4 - Surge Protectors for fire Alarm | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Fire alarm | DAC40CS-11-275 | Type 2 (or 3) surge protector - Compact - Single phase | | | Fire alarm | DAC40CS-31-275 | Type 2 (or 3) surge protector - Compact - 3-phase | |
5 - Surge Protector for Acces Control | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Access control | DLA | Dataline surge protectors - DIN rail mounting | |
6 - Surge Protector for LED Lighting | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Inside the cutouts of led lighting pole | DLPM1-230L | 230 V single phase surge protector - DIN rail mounting | |
| --- | --- | |
Download flyer
|
Watch video
| | | |
Surge Protection for Wind Turbine installation
. Selection of SPDs
1 - 230V / 400 V | | Description | Model | | --- | ---- | --- | | | Type 1+2+3 surge protector - VG Technology - Uc : 760V |DACN1-25CVGS-30-760 | | | 3-phase Type 2 surge protector - Uc : 760V |DAC50S-30-760 | | | 3-phase Type 2 surge protector - Uc : 800V |DAC50S-31-760-2600DC | 2 - 690 V | | Description | Model | | --- | ---- | --- | | | Type 2+3 surge protector - Uc : 1260V |DACN30VGS-30-1260 | | | Type 2 surge protector - Uc : 1100V |DS41S-1000 | 3 - Datalines | | Description | Model | | --- | ---- | --- | | | 1-pair Telecom-Data surge protector - DIN rail mounting - Ultra compact |DLC-24D3/RE | | | RJ45 surge protector for POE++ networks |
MJ8
-POE-A-SD | 4 - Counter | | Description | Model | | --- | ---- | --- | | | Lightning monitoring system for windturbines |LMS-W |
Download Windturbine flyer
Citel, SPDs for Energy Storage System ESS
. Surge Protectors selection
| Location | | Description | Model | | --- | --- | ---- | --- | | DC Battery protecgtion | | Kit ESS: 1500Vdc surge protector + Fusible |KIT ESS DDC50S-21Y-1500 | | Main Electrical Panel | | Type 1+2+3 AC surge protector 3-phase+N |DAC1-13VGS-31-275 | | Main Electrical Panel | | Fuse + Holders for 3-phase+N surge protector |SFD1-13S-31 | | Secondary panel | | Type 2 AC surge protector 3-phase+N |DACF25S-31-275 | | Control Sytems | | 1-pair Data surge protector pluggable |DLA-24D3 | | Control Systems | | POE++ and Cat.6A surge protector |
MJ8
-POE-C6A | | Connected PV site | | Type 2 PV surge protector 1500Vdc |DPVN40CVGS-21Y-1500 | | Windturbines | | Type 1+2+3 AC surge protector single-phase|DACN1-25VGS-10-440 |
| --- | |
Download flyer
| | |
PDF Found
mj8
No result found