Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 2 AC surge protector
DS440-120/G
Compact 3-phase+N Type 2 surge protector -120/208 V - Pluggable
DS440-120/G
Part Number
311622
Discover our latest innovation : the
DAC40C-31-150
Compact 3-Phase Type 2 surge protector
In : 20 kA
Imax : 40 kA
Common/Differential mode
Pluggable module
Remode Signaling contact option
EN 61643-11, IEC 61643-11, UL1449 ed.5 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
The DS440 Type 2 surge protectors are compact devices designed to protect 3-phase+N networks at the main switchboard. They provide a common or common/differential mode protection. This SPD is based on high energy varistor equipped with thermal disconnectors and failure indicator to comply with standards. The DS440 is DIN rail compatible and is built with a plug-in module and fixed base, which allows an easy and fast maintenance.
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
IEC
2
Network
120/208 V 3-phase
AC system
TT-TN
Nominal line voltage
Un
120 Vac
Max. AC operating voltage
Uc
150 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
180 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
230 Vac disconnection
Temporary Over Voltage N/PE (TOV HT)
Without disconnection or with safety disconnection
UT
1200 V/300A/200 ms withstand
Residual Current
Leakage current to Ground
Ipe
None
Operating current
Continious current at Uc
Ic
0.5 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
40 kA
Connection mode(s)
L/N and N/PE
Protection mode(s)
Common/Differential mode
Residual voltage at 5 kA
@ 5 kA (8/20µs)
Up-5kA
1.5/0.6 kV
Protection level L/N
@ In (8/20µs)
Up L/N
0.9 kV
Protection level N/PE
@ In (8/20µs)
Up N/PE
1.5 kV
Admissible short-circuit current
Isccr
10 000 A
Technology
MOV
SPD configuration
3-phase+Neutral
Connection to Network
By screw terminals: 1.5-10mm² (L/N) or 2.5-25mm² (PE)
Format
Plug-in modular box
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
3 mechanical indicators
Spare module(s)
DSM440-120/G and DSM440-120/GPE
Remote signaling of disconnection
Option DS440S-120/G : output on changeover contact
Dimensions
See diagram
Weight
0.197 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
50 A min. - 125 A max. - Fuses Type gG
×
Description:
Compact 3-phase+N Type 2 surge protector -120/208 V - Pluggable
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
EAC
Technology:
MOV
SPD configuration:
3-phase+Neutral
Remote signaling of disconnection:
Option DS440S-120/G : output on changeover contact
SPD type :
2
Network:
120/208 V 3-phase
AC system:
TT-TN
Max. AC operating voltage :
150 Vac
Residual Current :
None
Max. discharge current :
40 kA
Admissible short-circuit current:
10 000 A
CITEL
Reference:
DS440-120/G
Part Number:
311622
Or equivalent
Select your protection
Discover our new video!
Read more
Citel presents its new range AC and DC SPDs
Read more