Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Telecom
DIN Rail Telecom/Data surge protector
DLAWTS1-24D3
1-pair DIN rail plug-in Data surge protector
DLAWTS1-24D3
Part Number
6421031
Surge protection for 1-pair
Pluggable protection module
Optical fault indication
Remote signalling (DLAWTS1-48DC required for power supply)
Indirect shield connection
Indirect earthing
Signal interruption when module is disconnected
Conforms to IEC 61643-21, VDE 0845-3-1 and UL497A
Datasheet
Installation Sheet
Tender specifications
Contact Us
The surge protection devices of the DLAWTS series protect I&C, telecommunication and data technology systems against lightning effects and overvoltages. These surge protectors have been developed for the protection of one twin wire and can be used for all applications with voltages from 6 V to max. 170 V and transmission rates up to 10 Mbps. The electrical circuitry of the DLAS consists of a combination of high-performance gas discharge tubes and fast-switching diodes for high discharge capacity and fast response. The shield connection is additionally earthed via a gas discharge tube. Earthing is simply done via the top-hat rail. When the plug-in module is disconnected, the transmission signal is interrupted. Error signalling is via a visual display and remote signalling.
Select another reference:
DLAWTS1-06D3
DLAWTS1-06D3/R
DLAWTS1-12D3
DLAWTS1-12D3/R
DLAWTS1-170
DLAWTS1-170/R
DLAWTS1-24D3
DLAWTS1-24D3/R
DLAWTS1-48D3
DLAWTS1-48D3/R
Electrical Properties
Mechanical Properties
Norms
Schemas
Network
4-20 mA
Nominal line voltage
Un
24 V
Max. AC operating voltage
Uc
20 Vac
Max. DC operating voltage
Uc
28 Vdc
Max. frequency
f max.
> 3 MHz
Insertion loss
< 1 dB
Max. load current
@25°C
IL
300 mA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
20 kA
Line inductance (± 10 %)
non
Protection mode(s)
Common/Differential mode
Protection level
@ In (8/20 µs)
Up L/L
40 V
Max. capacitance
C
< 50 pF
Impulse current
2 x 10/350µs Test - D1 Category
Iimp
5 kA
Nominal discharge current
C2 Category
In
5 kA
Line/Line Nominal discharge current
C2 Category
In L/L
5 kA
Nominal Discharge Current, X-C (Line/Earth)
8/20µs Test x 10 - C2 Category
In L/PE
5 kA
Line resistance (± 10%)
4.7 Ohm
Network type
Data Communication
Technology
GDT+Clamping diode+PTC (thermal resistor) + Resistor
SPD configuration
1-pair+shielded
Connection to Network
By screw terminal: cross section 0.5-2.5mm²
Format
Plug-in DIN box
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Specific version with line cut-off in case of removal plug-in module
With line cut-off in case of removal plug-in module
Yes
Disconnection indicator
Red light on
Spare module(s)
DLAWTS1M-24D3
Remote signaling of disconnection
Trough control module
Dimensions
See diagram
Weight
0.065 kg
Standards compliance
IEC 61643-21 / EN 61643-21 / UL497A
×
Description:
1-pair DIN rail plug-in Data surge protector
Standards compliance:
IEC 61643-21 / EN 61643-21 / UL497A
Technology:
GDT+Clamping diode+PTC (thermal resistor) + Resistor
SPD configuration:
1-pair+shielded
Remote signaling of disconnection:
Trough control module
Network:
4-20 mA
Max. AC operating voltage :
20 Vac
Max. DC operating voltage:
28 Vdc
Max. discharge current :
20 kA
CITEL
Reference:
DLAWTS1-24D3
Part Number:
6421031
Or equivalent