Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)

1-pair DIN rail plug-in Data surge protector

DLAH-12D3
Part Number 641002
DLAH-12D3
  • Pluggable surge protection for «DIN» mounting
  • Coordination inductor
  • Up to 2.4 A line current
  • Remote supply version
  • All types of Telephone and Data lines
  • Shield wire protection
  • IEC 61643-21 compliance

DLAH surge protectors are designed to protect, against surge voltages due to lightning, terminals equipment connected to industrial buses, telecom lines or datalines. These surge protectors must be installed on symmetrical DIN rail and are available for most of the transmission lines: line voltage from 6 to 170V, bitrate up to 10 Mbit/s. These products are 1-pair surge protectors with removable module for easy maintenance.

Select another reference:

Network

RS232, RS485

Nominal line voltage
Un

12 V

Max. DC operating voltage
Uc

15 Vdc

Cut-off frequency
-3dB, 100 ohm system
f max.

> 1.8 MHz

Cut-off frequency
-1dB, 100 ohm system
f max.

> 1 MHz

Max. load current @25°C
IL

2.4 A

Max. discharge current
max. withstand @ 8/20 µs by pole
Imax

20 kA

Line inductance (± 10 %)

10 µH

Protection Level
C3 (10/1000μs), 300 applications@10 A, X-X (Line/Line)
Up

30 V

Protection level
C3 (10/1000μs), 300 applications@10 A, X-C (Line/Earth)
Up

30 V

Impulse current
2 x 10/350µs Test - D1 Category
Iimp

5 kA

Line/Line Nominal discharge current
C2 Category
In L/L

5 kA

Nominal Discharge Current, X-C (Line/Earth)
8/20µs Test x 10 - C2 Category
In L/PE

5 kA

Network type

Data Communication

Technology

GDT+TVS diode

SPD configuration

1-pair+shielded

Connection to Network

By screw terminal: cross section 0.4-1.5mm²

Format

Plug-in DIN box

Mounting

Symmetrical rail 35 mm (EN 60715)

Housing material

Thermoplastic UL94 V-0

Operating temperature
Tu

-40/+85°C

Protection rating

IP20

Failsafe mode

Short-circuit

Disconnection indicator

Transmission interrupt - default mode 2

Spare module(s)

DLAHM-12D3

Dimensions

See diagram

Standards compliance

IEC 61643-21 / EN 61643-21 / UL497B

Certification

UL Listed