Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Search
Product Selection
DLA-06D3
DLA-06D3
DLA
surge protectors are designed to protect, against surge voltages due to lightning, terminals equipment connected to industrial buses, telecom lines or datalines.
DLA
-
06D3
DLA
DLA
Series UL497B 1 pair, 2 wire + shield + ground 12V to 170V DC
DLAM-
06D3
DLA-06D3/R
DLA
surge protectors are designed to protect, against surge voltages due to lightning, terminals equipment connected to industrial buses, telecom lines or datalines.
DLA
-
06D3
/R
DLA
DLA
Series UL497B 1 pair, 2 wire + shield + ground 12V to 170V DC
DLAM-
06D3
DLATS-06D3
-
Discover our latest innovation : the
DLAWTS1-
06D3
- 1-pair dataline/telecom surge protection - Din rail mounting - Plug-in module - Local and Remote signaling of SPD status (functional/failure) - 1 control module (white) + SPD modules (yellow): 24 SPDs maximum by control module - Maximum dsicharge current Imax: 20kA - Compliance with IEC/EN 61643-21,UL 497A, GB 188002.21
Stopped production - REPLACED BY: DLATS1-
06D3
(6417011)
DLATS-
06D3
DLAMTS-
06D3
DLATS-06D3/R
-
Discover our latest innovation : the
DLAWTS1-
06D3
/R
- 1-pair dataline/telecom surge protection - Din rail mounting - Plug-in module - Local and Remote signaling of SPD status (functional/failure) - 1 control module (white) + SPD modules (yellow): 24 SPDs maximum by control module - Maximum dsicharge current Imax: 20kA - Compliance with IEC/EN 61643-21,UL 497A, GB 188002.21
Stopped production - REPLACED BY: DLATS1-
06D3
/R (6417014)
DLATS-
06D3
/R
DLAMTS-
06D3
DLAS-06D3/R
DLA
surge protectors are designed to protect, against surge voltages due to lightning, terminals equipment connected to industrial buses, telecom lines or datalines.
-
Discover our latest innovation : the
DLAWS1-
06D3
/R
- Din rail plug-in surge protector - 1-pair - Visual indicator in failsafe behaviour - Un: 24 V - Shield wire protection - Line cut off when plug out module - IEC 61643-21 compliance - UL497B approved
DLAS-
06D3
/R
DLAS
series UL497B 1 pair, 2 wire + shield + ground 12V to 48V DC Visual Indicator
DLASM-
06D3
B480-06D3
B480-
06D3
S480-
06D3
DLU2-06D3
DLU2-
06D3
DLATS1-06D3
DLA
surge protectors are designed to protect, against surge voltages due to lightning, terminals equipment connected to industrial buses, telecom lines or datalines.
DLATS1-
06D3
DLATS1M-
06D3
DLAWS1-06D3
The electrical circuitry of the
DLAS
consists of a combination of high-performance gas discharge tubes and fast-switching diodes for high discharge capacity and fast response.
DLAWS1-
06D3
DLAWS1M-
06D3
DLA2-06D3
DLA
protect I&C, telecommunication equipment and data technology systems from lightning effects and surges. Designed for DIN rail mounting, these surge protectors can be used for all applications with voltages from 6 V to max. 170 V and transmission rates up to 10 Mbit/s and protect one (
DLA
) to two (DLA2) pairs with a plug-in protection module. The electrical circuit of the
DLA
consists of a combination of high-performance gas discharge tubes and fast-switching diodes for high discharge capacity and fast response behaviour.
DLA2-
06D3
DLA2M-
06D3
DLAS1-06D3
DLAS1-
06D3
DLAS1M-
06D3
DLAH-06D3
DLAH-
06D3
DLAHM-
06D3
B280-06D3
B280-
06D3
S280-
06D3
DLAW-06D3
DLA
surge protectors are designed to protect, against surge voltages due to lightning, terminals equipment connected to industrial buses, telecom lines or datalines.
DLAW-
06D3
DLAM-
06D3
DLAWTS1-06D3
The electrical circuitry of the
DLAS
consists of a combination of high-performance gas discharge tubes and fast-switching diodes for high discharge capacity and fast response.
DLAWTS1-
06D3
DLAWTS1M-
06D3
B180-06D3
B180-
06D3
S180-
06D3
DLU-06D3
DLU-
06D3
DLC-06D3
DLC-
06D3
Range Selection
DLA-06D3
Range DLA - DLA-06-IS
Range DLA2 - DLA2-06D2
Pages
DLA-06D3
Citel, Water Waste Treatment
Implementation of coordinated system of protection against transient overvoltages |--- | --- | --- | --- | | Number | Location | Models | | 1 | AC power - Main electrical panel | DAC1-13VGS-31-275 | | | 1 | | DS254VG-300/G | | | 2 | Coaxial antenna - Radio wireless | P8AX | | | 3 | AC power - Distribution panel | DAC40CS-31-275 | | | 4 et 5 | Control circuit - Remote management | DAC15CS-31-275 | | 6 | Telecom-Data-Ethernet |
DLA
| | | 6 | | MJ8-POE-C6A | | | 7 | Control room | DAC50S-31-275 | | | 7 | | MJ8-POE-C6A | | | 7 | |
DLA
| | | --- | | Download flyer | | |
CITEL, surge protectors for data center
|Position | | Description | Model | | --- | --- | ---- | --- | | 1 | | Compact Type 2 surge protector 3-phase+N |DAC40CS-31 | | 2 | | Rack 19" protection | RAK16-E-C6 | | 3 | | CAT5 - CAT6 surge protection | MJ8-C6A | | 4 | | Type 1+2+3 AC surge protector 3-phase+N | DAC1-13VGS-31 | | 5 | | 1-pair Din rail plug-in data surge protector|
DLA
-24D3 |
Citel, surge protection for radiocom site
. Selection of SPDs |Position | | Description | Model | | --- | --- | ---- | --- | | 1 | | 'Quarter Wave' Coaxial SPD type 7/16 |PRC1800-716/MF | | 2 | | Type 1 and Type 2 DC surge protector | DS252C-48DC/G | | 3 | | 3-phase+N Type 1+2 AC surge protector | DAC1-13S-31-275 | | 3 | | Type 1+2+3 AC surge protector | DS254VG-300/G | | 4 | | 1-pair Data surge protector |
DLA
-24D3 | | --- | |
Watch video
| | |
CITEL, PV surge protectors for PV power plants
| --- | --- | --- | --- | | Location | | Model | Description | | PV network | | DS60VGPV-1500G/51 | Type 1 + 2 Photovoltaic surge protector
Iimp 12,5 kA - VG Technology | |PV Network | | DS50VGPVS-1000/12KT1 | Type 1 + 2 Photovoltaic surge protector
Iimp/Itotal : 6.25 / 12.5 kA (10/350µs) - VG Technology | |AC Network | | DAC1-13S-31-275 | Type 1+2 AC surge protector
In 20 kA - Remote signaling | |DATA Network | |
DLA
-24D3 | 1-pair pluggable surge protector
In 5 kA - Imax 20 kA - Remote signaling | | --- | --- | |
Download flyer
|
Watch video
| | | |
Citel, SPDs for Energy Storage System ESS
. Surge Protectors selection
| Location | | Description | Model | | --- | --- | ---- | --- | | DC Battery protecgtion | | Kit ESS: 1500Vdc surge protector + Fusible |KIT ESS DDC50S-21Y-1500 | | Main Electrical Panel | | Type 1+2+3 AC surge protector 3-phase+N |DAC1-13VGS-31-275 | | Main Electrical Panel | | Fuse + Holders for 3-phase+N surge protector |SFD1-13S-31 | | Secondary panel | | Type 2 AC surge protector 3-phase+N |DACF25S-31-275 | | Control Sytems | | 1-pair Data surge protector pluggable |
DLA
-24D3 | | Control Systems | | POE++ and Cat.6A surge protector |MJ8-POE-C6A | | Connected PV site | | Type 2 PV surge protector 1500Vdc |DPVN40CVGS-21Y-1500 | | Windturbines | | Type 1+2+3 AC surge protector single-phase|DACN1-25VGS-10-440 |
| --- | |
Download flyer
| | |
CITEL, PV surge protectors for industrial and public building
| --- | --- | --- | --- | | Location | | CITEL model | Description | | PV NETWORK | | DPVN-40CVGS-21Y-1200 | Type 2 PV surge protector
In 20kA - Imax 40kA - Remote signaling | |PV NETWORK | | DS50PVS-600/51 | Type 2 PV surge protector
In 15kA - Imax 40 kA - Remote signaling | |AC NETWORK | | DAC50S-31-275 | Type 2 AC surge protector
In 20 kA - Imax 50 kA - Remote signaling | |AC NETWORK | | DAC40CS-31-275 | Type 2 AC surge protector
In 20 kA - Imax 40 kA - Remote signaling - Compact | |DATA NETWORK | |
DLA
-24D3 | 1-pair pluggable surge protector
In 5 kA - Imax 20 kA - Remote signaling | | --- | --- | |
Download the flyer
|
Watch video
| | | |
PDF Found
DLA-06D3