Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)

Surge protector for Video survey



Select another reference:

Network
2 pairs signal 0-5 V
Network
Signal video
Network
230 V single-phase
AC system
TT-TN
Max. DC operating voltage
Uc 8 Vdc
Max. DC operating voltage
Uc 255 Vdc
Max. DC operating voltage
Uc 6 Vdc
Max. frequency
f max. 100 Mhz
Max. frequency
f max. 16 Mhz
Max. frequency
f max. 16 MHz
Insertion loss
< 0.1 dB
Insertion loss
< 1dB
Insertion loss
< 1dB
Max. load current
@25°C
IL 5 A
Max. load current
@25°C
IL 300 mA
Max. load current
@25°C
IL 300 mA
Operating current
Continious current at Uc
Ic None
Nominal discharge current
15 x 8/20 µs impulses
In 5 kA
Nominal discharge current
15 x 8/20 µs impulses
In 5 kA
Nominal discharge current
15 x 8/20 µs impulses
In 2.5 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax 10 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax 10 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax 5 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc 10 kV / 5 kA
Protection mode(s)
Common/Differential mode
Protection level
@ In (8/20µs)
Up 20 V
Protection level
@ In (8/20µs)
Up 20 V
Protection level
@ In (8/20µs)
Up 1.2 kV
Protection level
@ In (8/20 µs)
Up L/L 20 V
Technology
MOV+GDT
Connection to Network
By screw terminals: 2.5mm² max.
Format
DIN rail or flange
Mounting
DIN rail or plate (flange)
Housing material
Anodized aluminum
Operating temperature
Tu -40/+85°C
Protection rating
IP20
Failsafe mode
Green LED OFF and line cut-off
Disconnection indicator
LED green OFF and AC network cut-off
Dimensions
See diagram
Weight
0.176 kg
Standards compliance
IEC 61643-21 / EN 61643-21 / UL1449 ed.5