Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 2 (or 3) AC surge protector
DACN15-P11-150
Compact single-phase type 2 (or 3) surge protector - Monobloc
DACN15-P11-150
Part Number
70146011
Compact single-phase Type 2 (or 3) surge protector
In : 5 kA
Imax : 15 kA
Commun/Differential mode
Monobloc module
Remote signaling option
EN 61643-11, IEC 61643-11 and UL1449 ed.5 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2 (or 3)
Network
120/208 V
AC system
TT-TN
Max. AC operating voltage
Uc
150 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
180 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
230 Vac disconnection
Temporary Over Voltage N/PE (TOV HT)
Without disconnection or with safety disconnection
UT
1200 V/300A/200 ms withstand
Residual Current
Leakage current to Ground
Ipe
None
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
5 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
15 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
10 kV
Protection mode(s)
L/N and N/PE
Protection level L/N
@ In (8/20µs)
Up L/N
0.7 kV
Protection level N/PE
@ In (8/20µs)
Up N/PE
1.5 kV
Admissible short-circuit current
Isccr
10 000 A
Technology
MOV+GDT
SPD configuration
Single phase
Connection to Network
By screw terminals: 1.5-10mm²
Compact
Yes
Format
Monobloc modular box
Plugable
No
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
Green LED OFF
Remote signaling of disconnection
Option DACN15S-P11-150: output on changeover contact
Dimensions
See diagram - 1TE (EN43880)
Weight
0.090 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
20 A min. - 125 A max. - Fuses type gG
×
Description:
Compact single-phase type 2 (or 3) surge protector - Monobloc
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Technology:
MOV+GDT
SPD configuration:
Single phase
Compact:
Yes
Remote signaling of disconnection:
Option DACN15S-P11-150: output on changeover contact
SPD type :
2 (or 3)
Network:
120/208 V
AC system:
TT-TN
Max. AC operating voltage :
150 Vac
Residual Current :
None
Max. discharge current :
15 kA
Admissible short-circuit current:
10 000 A
CITEL
Reference:
DACN15-P11-150
Part Number:
70146011
Or equivalent