Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 1 and Type 2 DC surge protector
DDC30S-10-85
1-pole Type 1 and Type 2 SPD for 48 Vdc
DDC30S-10-85
Part Number
828110221
Combined SPD Type 1+2 for DC supplies, 1-pole
Type 1 + 2
In: 20 kA / Imax: 30 kA
Iimp: 4kA
Pluggable module
Remote signaling
prIEC 61643-41 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
The DDC range is Type 1 + 2 pluggable surge protectors designed for equipment connected to DC powerlines. The technology based on high energy varistor equipped with thermal disconnection mechanism offers protection efficiency and and a maximal reliability.
Select another reference:
DDC30S-10-65
DDC30S-10-85
DDC30S-20-65
DDC30S-20-85
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
IEC
1+2
Nominal DC voltage
Un-dc
75 Vdc
Max. AC operating voltage
Uc
60 Vac
Max. DC operating voltage
Uc
85 Vdc
Residual Current
Leakage current to Ground
Ipe
< 0.1 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
30 kA
Impulse current by pole
max. withstand 10/350µs by pole
Iimp
4 kA
Connection mode(s)
+/PE or -/PE
Protection level +/PE (-/PE)
@ In (8/20µs)
Up
390 V / -
Admissible short-circuit current
Isccr
50 000 A
Network type
DC
Technology
MOV
SPD configuration
Single phase
Connection to Network
Srew terminals: 2.5-25mm² +/-: 1.5-10mm²
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Outdoor application
No
Failsafe mode
Disconnection from DC network
Disconnection indicator
1 mechanical indicator - Red/Green
Spare module(s)
MDDC30-85
Remote signaling of disconnection
Output on changeover contact
Dimensions
See diagram - 1TE (EN43880)
Weight
0.070 kg
Standards compliance
prIEC 61643-41
Thermal disconnector
Internal
Back-up protection device
50 A min. - 125 A max. - Fuses Type gG
×
Description:
1-pole Type 1 and Type 2 SPD for 48 Vdc
Standards compliance:
prIEC 61643-41
Technology:
MOV
SPD configuration:
Single phase
Remote signaling of disconnection:
Output on changeover contact
SPD type :
1+2
Max. AC operating voltage :
60 Vac
Max. DC operating voltage:
85 Vdc
Residual Current :
< 0.1 mA
Max. discharge current :
30 kA
Impulse current by pole :
4 kA
Admissible short-circuit current:
50 000 A
CITEL
Reference:
DDC30S-10-85
Part Number:
828110221
Or equivalent
Select your protection
Discover our new video!
Read more
Citel presents its new range AC and DC SPDs
Read more