Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)

Outdoor gigabit 10G POE++ surge protector

LAN-10G-POE-G-C
Part Number 581549
LAN-10G-POE-G-C
  • POE++ Compatible (IEEE 802.3bt) -10Gb (5-100m) with Cat6A S/FTP cabling
  • Shielded RJ45 connectors
  • Outdoor applications, IP54 (NEMA 3)
  • Plastic enclosure, UL94-V0
  • Conforms to IEC/EN 61643-21
  • SPD categories D1, C3, C2

The CMJ8-POE is an outdoor PoE surge protector designed to protect sensitive data-processing equipment connected to a PoE (Power over Ethernet) network from transient over voltages. The CMJ8-POE surge protector is deployed in signal network applications with data transmission speeds up to1000 Mbps and is equipped with high quality shielded RJ45 connectors.

Select another reference:

Network
10Gb/s on Cat6A S/FTP cabling
Protection modes (network)
CM (Common Mode)
Protection modes (POE)
CM (Common Mode)
Transmission standard
IEEE 802.3bt
Lightning Protection Zones (LPZ)
0 - 2
Max. DC operating voltage
Uc 8 Vdc
Max. operating voltage (POE)
Uc 60 Vdc
Max. frequency
f max. 500 MHz
Max. data rate
10 Gbps
Max. load current
@25°C
IL 2 A
Max. POE power (4PPOE)
90 W
Max. discharge current
max. withstand @ 8/20 µs, X-C (Line/Earth)
Imax 2 kA
Protection Level
C3 category (10/1000μs), 300 applications@10 A, X-X (Line/Line)
Up 700 V
Protection level
C3 category (10/1000μs), 300 applications@10 A, X-C (Line/Earth)
Up 700 V
Protection Level
C3 Category (10/1000µs), 300 applications @ 10A, (Pair-Pair, POE)
Up 700 V
Impulse current
D1 category (10/350μs), 2 applications, X-C (Line/Earth)
Iimp 500 A
Nominal Discharge Current
C2 category (8/20μs), 10 applications, X-X (Line/Line)
In 4 kV / 2 kA
Nominal discharge current
C2 category (8/20μs), 10 applications X-C (Line/Earth)
In 4 kV / 2 kA
Line resistance (± 10%)
0 Ohm
Capacitance
@1MHz, X-C (Line/Earth)
C < 5 pF
Network type
Cat6A (10Gb/s on S/FTP cabling)
Technology
Gas discharge tube
SPD configuration
8 wires+shielded
Connection to Network
RJ45 shielded connectors Female input/output
Cable glands
Rubber
Format
Plastic Box with connectors input/output
Mounting
Wall / Pole / Plate
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu -40/+85°C
Protection rating
IP54
Outdoor application
Yes
Failsafe mode
Short-circuit - transmision cut-off - fault mode 2
Pinout
(1-2)(3-6)(4-5)(7-8)
Dimensions
See diagram
Weight
0.14 kg / 0.31 lbs
Standards compliance
IEC 61643-21 / EN 61643-21 / UL497B / IEEE 802.3af/3at/3bt, ANSI/TIA-568-c.1