Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)

D-sub dataline surge protector

DD9-24V
Part Number 6147
DD9-24V
  • D-Sub surge protector
  • For RS232, RS485 communication lines
  • 9-pin connector
  • Fast and easy installation
  • Secondary protection

DD9ESD surge protector are designed to protect sensitive equipment linked to datalines equipped with D-sub connectors, as RS232, RS422 and RS485lines. They are equipped with D-sub connectors for fast and easy maintenance. In order to comply with the line configuration, all the wires are transmitted and protected.

Select another reference:

Network
RS232, RS485, 4-20mA
Nominal line voltage
Un 24 Vdc
Max. DC operating voltage
Uc 40 Vdc
Max. frequency
f max. > 10 MHz
Max. data rate
< 40 Mbps
Insertion loss
< 1 dB
Max. load current
@25°C
IL 750 mA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax 125 A
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total 1125 A
Line inductance (± 10 %)
non
Protection mode(s)
Common mode
Protection Level
C3 category (10/1000μs), 300 applications@10 A, X-X (Line/Line)
Up 130 V
Protection level
C3 category (10/1000μs), 300 applications@10 A, X-C (Line/Earth)
Up 65 V
Nominal Discharge Current
C2 category (8/20μs), 10 applications, X-X (Line/Line)
In 125 A
Nominal discharge current
C2 category (8/20μs), 10 applications X-C (Line/Earth)
In 125 A
Line resistance
< 0.05 Ohm
Capacitance
@1MHz, X-C (Line/Earth)
C < 500 pF
Technology
Diode écrêtage
SPD configuration
9 wires
Connection to Network
D-Sub 9 pts male/female Input/output
Format
In/out D-Sub connector unit
Mounting
On cable
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu -40/+85°C
Protection rating
IP20
Outdoor application
No
Failsafe mode
Short-circuit - transmision cut-off - fault mode 2
Disconnection indicator
Transmission interrupt
Remote signaling of disconnection
No
Pinout
all wires transmitted and protected
Dimensions
See diagram
Weight
0.063 kg
Standards compliance
IEC 61643-21 / EN 61643-21 / UL497B
Certification
UL 497B