Compact 3-phase+N Type 2 surge protector - 230/400 V - Pluggable
DS415-230
Part Number 451702
- Discover our latest innovation : the DAC15C-40-275
- Compact 3-phase+N type 2 (or 3) surge protector
- In: 5 kA
- Imax: 15 kA
- Common mode
- Pluggable module
- Remote signaling option
- EN 61643-11, IEC 61643-11, UL1449 ed.5 compliance
The DS415 Type 2 surge protectors are compact devices designed to protect 3-phase+N networks at the main switchboard.
They provide a common or common/differential mode protection.
This SPD is based on high energy varistor equipped with thermal disconnectors and failure indicator to comply with standards.
The DS415 is DIN rail compatible and is built with a plug-in module and fixed base, which allows an easy and fast maintenance.
Select another reference:
SPD type
|
IEC | 2 (or 3) |
Network
|
230/400 V 3-phase | |
AC system
|
TN | |
Nominal line voltage
|
Un | 230 Vac |
Max. AC operating voltage
|
Uc | 255 Vac |
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
|
UT | 335 Vac withstand |
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
|
UT | 440 Vac disconnection |
Residual Current
Leakage current to Ground
|
Ipe | < 0.5 mA |
Operating current
Continious current at Uc
|
Ic | 0.5 mA |
Follow current
|
If | None |
Nominal discharge current
15 x 8/20 µs impulses
|
In | 5 kA |
Max. discharge current
max. withstand @ 8/20 µs by pole
|
Imax | 15 kA |
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
|
Uoc | 10 kV |
Withstand on overvoltages IEEE C62.41.1
|
10 kV | |
Connection mode(s)
|
L/N and N/PE | |
Protection mode(s)
|
Common mode | |
Residual voltage at 5 kA
@ 5 kA (8/20µs)
|
Up-5kA | 0.9 kV |
Protection level CM/DM
@ In (8/20µs)
|
Up mc/md | 0.9 kV |
Admissible short-circuit current
|
Isccr | 10 000 A |
Technology
|
MOV | |
SPD configuration
|
3-phase+Neutral | |
Connection to Network
|
By screw terminals: 1.5-10mm² (L/N) or 2.5-25mm² (PE) | |
Format
|
Plug-in modular box | |
Mounting
|
Symmetrical rail 35 mm (EN 60715) | |
Housing material
|
Thermoplastic UL94 V-0 | |
Operating temperature
|
Tu | -40/+85°C |
Protection rating
|
IP20 | |
Failsafe mode
|
Disconnection from AC network | |
Disconnection indicator
|
4 mechanical indicators | |
Spare module(s)
|
DSM415-230 | |
Remote signaling of disconnection
|
Option DS415S-230 : output on changeover contact | |
Dimensions
|
See diagram |
Standards compliance
|
IEC 61643-11 / EN 61643-11 / UL1449 ed.5 | |
Certification
|
Thermal disconnector
|
Internal | |
Installation ground fault breaker
|
Type 'S' or delayed | |
Back-up protection device
|
20 A min. - 125 A max. - Fuses type gG |