Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 2 AC surge protector
DAC50-11-150
Type 2 AC surge protector - Single-phase
DAC50-11-150
Part Number
821110132
Availability:
€74.00 (excl. tax)
Add to cart
Shipping is only available to France.
OK
Available within 3 weeks
Type 2 AC surge protector
In: 20 kA
Imax: 50 kA
Pluggable module for each phase
Remote signaling option
EN 61643-11, IEC 61643-11 and UL1449 ed.5 certified
Datasheet
ULCertificate_DAC50-11-150.pdf
Installation Sheet
Tender specifications
Contact Us
The pluggable surge protectors Type 2 DAC50, are designed to protect AC powerline at the main switchboard of the installation. These SPDs are based on high energy varistor equipped with thermal disconnector and failure indicator, to comply with standards and to provide a maximum protection efficiency, a high impulse current capability and an improved reliability. The surge protectors DAC50 are available in multipolar version and in several voltages to protect single or 3-phase networks.
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2
Network
120 V single-phase
AC system
TT-TN
Max. AC operating voltage
Uc
150 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
180 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
230 Vac disconnection
Temporary Over Voltage N/PE (TOV HT)
Without disconnection or with safety disconnection
UT
1200 V/300A/200 ms withstand
Residual Current
Leakage current to Ground
Ipe
None
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
50 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
50 kA
Protection mode(s)
L/N and N/PE
Protection level
@ In (8/20µs) and @ 6 kV (1,2/50 µs)
Up L/N
0.9 kV
Protection level N/PE
@ In (8/20µs) and @ 6 kV (1,2/50 µs)
Up N/PE
1.5 kV
Residual voltage L/N at 5 kA
@ 5 kA (8/20µs)
Up-5kA
0.6 kV
Protection level N/PE at 5 kA
@ 5 kA (8/20µs)
Up-5kA
0.6 kV
Admissible short-circuit current
Isccr
50 000 A
Network type
AC
Technology
MOV+GDT
SPD configuration
Single phase
Connection to Network
By screw terminals: 2.5-25mm² (35mm² rigid)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole - Red/Green
Spare module(s)
MDAC50-440+MDAC50G-440
Remote signaling of disconnection
option DAC50S-11-150 : output on changeover contact
Wiring for remote signaling
1.5 mm² max.
Max. Voltage/Current for remote signaling
250 V / 0.5 A (AC) / 30 V / 3 A (DC)
Dimensions
See diagram - 2TE (EN43880)
Weight
0.179 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
OVE / UL
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
50 A min. - 125 A max. - Fuses Type gG
×
Description:
Type 2 AC surge protector - Single-phase
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
OVE / UL / EAC
Technology:
MOV+GDT
SPD configuration:
Single phase
Remote signaling of disconnection:
option DAC50S-11-150 : output on changeover contact
SPD type :
2
Network:
120 V single-phase
AC system:
TT-TN
Max. AC operating voltage :
150 Vac
Residual Current :
None
Max. discharge current :
50 kA
Total Maximum discharge current :
50 kA
Admissible short-circuit current:
50 000 A
CITEL
Reference:
DAC50-11-150
Part Number:
821110132
Or equivalent
Select your protection
Discover our new video!
Read more
Citel presents its new range AC and DC SPDs
Read more