Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 1+2 AC surge protector
DACN1-13S-10-760
Type 1+2 AC surge protector - 1-pole
DACN1-13S-10-760
Part Number
29111012
Type 1 + 2 AC surge protector
High energy discharge capacity(High duty)
In: 40 kA, Imax: 80kA
Iimp: 12.5 kA on 10/350µs impulse
Unpluggable module for each phase
Remote signaling
EN 61643-11, IEC 61643-11 complied
Datasheet
Installation Sheet
Tender specifications
Contact Us
The DACN1-13S is an high duty Type 1+2 SPD designed to protect AC powerline at the main switchboard of an installation equipped with lightning rod, and in wind turbines and photovoltaic' application. Equipped with CITEL’s high energy discharge capacity technology, the range achieves an requirement on extreme high duty level, guaranteeing the possible application for high exposure location or/and high thunderstorm area, to ensure a more longer lifetime than expected. Furthermore, higher Uc(760Vac) and extreme low Up(3.5kV@40kA) bring advantage on wider range of application and higher protection efficiency for instructions.
Select another reference:
DACN1-13S-10-760
DACN1-13S-20-760
DACN1-13S-30-760
DACN1-13S-40-760
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
1+2
Max. AC operating voltage
Uc
760 Vac
Max. load current
@25°C
IL
100 A
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
1000 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
1325 Vac disconnection
Residual Current
Leakage current to Ground
Ipe
None
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
40 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
80 kA
Impulse current by pole
max. withstand 10/350µs by pole
Iimp
12.5 kA
Specific energy by pole
max. withstand 10/350 µs
W/R
40 kJ/ohm
Protection level
@ In (8/20µs)
Up
3.5 kV
Residual voltage at 5 kA
@ 5 kA (8/20µs)
Up-5kA
2.3 kV
Admissible short-circuit current
Isccr
25 000 A
Technology
MOV
SPD configuration
Single phase
Connection to Network
By screw terminals: 2.5-25mm² (35mm² rigid)
Format
1-pole modular box
Plugable
No
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole - Red/Green
Remote signaling of disconnection
Output on changeover contact
Wiring for remote signaling
1.5 mm² max.
Max. Voltage/Current for remote signaling
250 V / 0.5 A (AC) / 30 V / 3 A (DC)
Dimensions
See diagram - 2TE (EN43880)
Weight
0.390 kg
Standards compliance
EN 61643-11 / IEC 61643-11
Certification
TUV Süd
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
Fuses Type gG - 125 A
×
Description:
Type 1+2 AC surge protector - 1-pole
Standards compliance:
EN 61643-11 / IEC 61643-11
Certification:
TUV Süd
Technology:
MOV
SPD configuration:
Single phase
Remote signaling of disconnection:
Output on changeover contact
SPD type :
1+2
Max. AC operating voltage :
760 Vac
Residual Current :
None
Max. discharge current :
80 kA
Impulse current by pole :
12.5 kA
Protection level :
3.5 kV
Admissible short-circuit current:
25 000 A
CITEL
Reference:
DACN1-13S-10-760
Part Number:
29111012
Or equivalent