Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 1+2 AC surge protector
DAC1-13-40-275
Type 1+2 AC surge protector - 3-phase+N
DAC1-13-40-275
Part Number
821710214
Type 1 + 2 AC multipolar surge protector
In: 20 kA
Iimp: 12.5 kA
Pluggable module for each phase
Remote signaling (option)
EN 61643-11, IEC 61643-11 certified
UL1449 ed.5 compliance
Datasheet
CITEL_Certif_EU_DAC1-13.pdf
Installation Sheet
Tender specifications
Contact Us
The DAC1-13 is an extreme duty Type 1+2 pluggable SPD designed to protect AC powerline at the main switchboard of an installation equipped with lightning rod. The technology ‘Multi-varistor” allows a very high discharge current capability in small dimensions and the best possible behavior to the AC network (no follow current). In the light of their high discharge capability, the DAC1-13 surge protectors are especially compact and are available in multipolar versions to protect single or 3-phase AC networks.
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
1+2
Network
230/400 V 3-phase+N
AC system
TNS
Max. AC operating voltage
Uc
275 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac disconnection
Residual Current
Leakage current to Ground
Ipe
< 1 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
50 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
200 kA
Impulse current by pole
max. withstand 10/350µs by pole
Iimp
12.5 kA
Total lightning current
max. total withstand @ 10/350µs
Itotal
50 kA
Specific energy by pole
max. withstand 10/350 µs
W/R
40 kJ/ohm
Protection mode(s)
L/PE and N/PE
Protection level N/PE
@ In (8/20µs)
Up N/PE
1.3 kV
Protection level L/PE
@ In (8/20µs)
Up L/PE
1.3 kV
Protection level N/PE at 5 kA
@ 5 kA (8/20µs)
Up-5kA
1 kV
Residual voltage L/PE at 5 kA
@ 5 kA (8/20µs)
Up-5kA
1 kV
Admissible short-circuit current
Isccr
50 000 A
Network type
AC
Technology
VG Technology (MOV+GSG)
SPD configuration
3-phase+Neutral
Connection to Network
By screw terminals: 2.5-25mm² (35mm² rigid)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole - Red/Green
Spare module(s)
MDAC1-13-275
Remote signaling of disconnection
option DAC1-13S-40-275: output on changeover contact
Dimensions
See diagram - 4TE (EN43880)
Weight
0.667 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
KEMA
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
Fuse assembly: SFD1-13S-40 /or 125 A min. - 315 A max. - Fuses Type gG
×
Description:
Type 1+2 AC surge protector - 3-phase+N
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
KEMA / EAC
Technology:
VG Technology (MOV+GSG)
SPD configuration:
3-phase+Neutral
Remote signaling of disconnection:
option DAC1-13S-40-275: output on changeover contact
SPD type :
1+2
Network:
230/400 V 3-phase+N
AC system:
TNS
Max. AC operating voltage :
275 Vac
Residual Current :
< 1 mA
Max. discharge current :
50 kA
Total Maximum discharge current :
200 kA
Impulse current by pole :
12.5 kA
Admissible short-circuit current:
50 000 A
CITEL
Reference:
DAC1-13-40-275
Part Number:
821710214
Or equivalent
Select your protection
Discover our new video!
Read more
Citel presents its new range AC and DC SPDs
Read more