Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Hard-wired AC surge protector
MSB10-31-230
Compact Type 2+3 hard wired surge protector
MSB10-31-230
Part Number
561223
Compact type 2 (or 3) surge protector
Wall mounting and hard wired connection
Status indicators
IP65
Datasheet
Installation Sheet
Tender specifications
Contact Us
Select another reference:
MSB10-120(UL)
MSB10-24
MSB10-31-230
MSB10-400
MSB10-400(UL)
MSB10-480(UL)
MSB10C-400
MSB10V-120
MSB10V-400
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2+3
Network
230/400 V 3-phase+N
AC system
TT-TN
Nominal line voltage
Un
230/400 Vac
Max. AC operating voltage
Uc
255 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac disconnection
Operating current
Continious current at Uc
Ic
< 1 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
5 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
10 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
6 kV
Withstand on overvoltages IEEE C62.41.1
10 kV / 10 kA
Protection mode(s)
Common/Differential mode
Protection level L/N
@ In (8/20µs)
Up L/N
1.5 kV
Protection level L/PE
@ In (8/20µs)
Up L/PE
1.5 kV
Admissible short-circuit current
Isccr
10 000 A
Technology
MOV+GDT
Connection to Network
Wires
Mounting
Wall or plate
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP65
Failsafe mode
Disconnection from AC network
Disconnection indicator
3-Green LED OFF
Voltage/operating indicator
3-Green Led ON
Dimensions
See diagram
Weight
0.105 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
×
Description:
Compact Type 2+3 hard wired surge protector
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
EAC
Technology:
MOV+GDT
SPD type :
2+3
Network:
230/400 V 3-phase+N
AC system:
TT-TN
Max. AC operating voltage :
255 Vac
Max. discharge current :
10 kA
Admissible short-circuit current:
10 000 A
CITEL
Reference:
MSB10-31-230
Part Number:
561223
Or equivalent
Select your protection
Discover our new video!
Read more
Citel presents its new range AC and DC SPDs
Read more