Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Search
Product Selection
DLC-170
DLC-170
DLC
compact surge protective devices (SPDs) are designed to protect terminal equipment connected to industrial buses, telecommunication lines or signalling applications from the effects of lightning and transient overvoltages. These SPDs are installed on symmetrical DIN rail, often within customer panels.
DLC
SPDs protect 1-pair applications and have a non-pluggable (monobloc) enclosure.
DLC
-
170
DLC
DLC
Series UL497B1 pair, 2 wire + shield + ground Compact 6mm module12V to 170V DC
DLATS-170
-
Discover our latest innovation : the
DLAWTS1-
170
- 1-pair dataline/telecom surge protection - Din rail mounting - Plug-in module - Local and Remote signaling of SPD status (functional/failure) - 1 control module (white) + SPD modules (yellow): 24 SPDs maximum by control module - Maximum dsicharge current Imax: 20kA - Compliance with IEC/EN 61643-21,UL 497A, GB 188002.21
Stopped production - REPLACED BY: DLATS1-
170
(6415051)
DLATS-
170
DLAMTS-
170
DLU2-170
- For DIN rail mounting - Monobloc housing - 2-pair - Uc :
170
V - IEC 61643-21 compliance - UL497A
DLU2-
170
DLU-170
- For DIN rail mounting - Monobloc housing - 1-pair - Uc :
170
V - Transmission an protection of shield wire - IEC 61643-21 compliance - UL497A
DLU-
170
DLA2-170
Designed for DIN rail mounting, these surge protectors can be used for all applications with voltages from 6 V to max.
170
V and transmission rates up to 10 Mbit/s and protect one (DLA) to two (DLA2) pairs with a plug-in protection module.
- Din rail plug-in surge protector - 2-pair - Uc:
170
V - Shield wire protection - Without line cut-off - IEC 61643-21 compliance - UL497B
DLA2-
170
DLA2M-
170
DLC-06DBC
DLC
compact surge protective devices (SPDs) are designed to protect terminal equipment connected to industrial buses, telecommunication lines or signalling applications from the effects of lightning and transient overvoltages. These SPDs are installed on symmetrical DIN rail, often within customer panels.
DLC
SPDs protect 1-pair applications and have a non-pluggable (monobloc) enclosure.
- Discover our latest innovation : the
DLC
-06D3
- High speed data transmission - Common mode and differential mode protection - Data lines, including those isolated from Earth - Compact DIN rail enclosure, high density protection - Protection of shield wire - Location and test categories: D1, C2, C3 - IEC 61643-21 compliance
DLC
-06DBC
DLC
DLC
Series UL497B1 pair, 2 wire + shield + ground Compact 6mm module12V to 170V DC
DLC-12DBC
DLC
compact surge protective devices (SPDs) are designed to protect terminal equipment connected to industrial buses, telecommunication lines or signalling applications from the effects of lightning and transient overvoltages. These SPDs are installed on symmetrical DIN rail, often within customer panels.
DLC
SPDs protect 1-pair applications and have a non-pluggable (monobloc) enclosure.
- Discover our latest innovation : the
DLC
-12D3
- High speed data transmission - Common mode and differential mode protection - Data lines, including those isolated from Earth - Compact DIN rail enclosure, high density protection - Protection of shield wire - Location and test categories: D1, C2, C3 - IEC 61643-21 compliance
DLC
-12DBC
DLC
DLC
Series UL497B1 pair, 2 wire + shield + ground Compact 6mm module12V to 170V DC
DLC-24DBC
DLC
compact surge protective devices (SPDs) are designed to protect terminal equipment connected to industrial buses, telecommunication lines or signalling applications from the effects of lightning and transient overvoltages. These SPDs are installed on symmetrical DIN rail, often within customer panels.
DLC
SPDs protect 1-pair applications and have a non-pluggable (monobloc) enclosure.
- Discover our latest innovation : the
DLC
-24D3
- High speed data transmission - Common mode and differential mode protection - Data lines, including those isolated from Earth - Compact DIN rail enclosure, high density protection - Protection of shield wire - Location and test categories: D1, C2, C3 - IEC 61643-21 compliance
DLC
-24DBC
DLC
DLC
Series UL497B1 pair, 2 wire + shield + ground Compact 6mm module12V to 170V DC
DLC-48DBC
DLC
compact surge protective devices (SPDs) are designed to protect terminal equipment connected to industrial buses, telecommunication lines or signalling applications from the effects of lightning and transient overvoltages. These SPDs are installed on symmetrical DIN rail, often within customer panels.
DLC
SPDs protect 1-pair applications and have a non-pluggable (monobloc) enclosure.
- Discover our latest innovation : the
DLC
-48D3
- High speed data transmission - Common mode and differential mode protection - Data lines, including those isolated from Earth - Compact DIN rail enclosure, high density protection - Protection of shield wire - Location and test categories: D1, C2, C3 - IEC 61643-21 compliance
DLC
-48DBC
DLC
DLC
Series UL497B1 pair, 2 wire + shield + ground Compact 6mm module12V to 170V DC
DLATS1-170
DLATS1-
170
DLATSM1-
170
DLAWTS1-170
These surge protectors have been developed for the protection of one twin wire and can be used for all applications with voltages from 6 V to max.
170
V and transmission rates up to 10 Mbps.
DLAWTS1-
170
DLAWTS1M-
170
DLAW-170
DLAW-
170
DLAM-
170
DLA-170
DLA-
170
DLAM-
170
DLAH-170
DLAH-
170
DLAHM-
170
DLC-48D3
DLC
compact surge protective devices (SPDs) are designed to protect terminal equipment connected to industrial buses, telecommunication lines or signalling applications from the effects of lightning and transient overvoltages. These SPDs are installed on symmetrical DIN rail, often within customer panels.
DLC
SPDs protect 1-pair applications and have a non-pluggable (monobloc) enclosure.
DLC
-48D3
DLC
DLC
Series UL497B1 pair, 2 wire + shield + ground Compact 6mm module12V to 170V DC
DLC-06D3G
DLC
compact surge protective devices (SPDs) are designed to protect terminal equipment connected to industrial buses, telecommunication lines or signalling applications from the effects of lightning and transient overvoltages. These SPDs are installed on symmetrical DIN rail, often within customer panels.
DLC
SPDs protect 1-pair applications and have a non-pluggable (monobloc) enclosure.
DLC
-06D3G
DLC
DLC
Series UL497B1 pair, 2 wire + shield + ground Compact 6mm module12V to 170V DC
DLC-48D2
DLC
compact surge protective devices (SPDs) are designed to protect terminal equipment connected to industrial buses, telecommunication lines or signalling applications from the effects of lightning and transient overvoltages. These SPDs are installed on symmetrical DIN rail, often within customer panels.
DLC
SPDs protect 1-pair applications and have a non-pluggable (monobloc) enclosure.
DLC
-48D2
DLC
DLC
Series UL497B1 pair, 2 wire + shield + ground Compact 6mm module12V to 170V DC
DLC-06D3
DLC
compact surge protective devices (SPDs) are designed to protect terminal equipment connected to industrial buses, telecommunication lines or signalling applications from the effects of lightning and transient overvoltages. These SPDs are installed on symmetrical DIN rail, often within customer panels.
DLC
SPDs protect 1-pair applications and have a non-pluggable (monobloc) enclosure.
DLC
-06D3
DLC
DLC
Series UL497B1 pair, 2 wire + shield + ground Compact 6mm module12V to 170V DC
Range Selection
DLC-170
Range DLC - DLC-06D2
Range DLC-24D3/RE - DLC-24D3/RE
Pages
DLC-170
Surge Protection for Wind Turbine installation
. Selection of SPDs
1 - 230V / 400 V | | Description | Model | | --- | ---- | --- | | | Type 1+2+3 surge protector - VG Technology - Uc : 760V |DACN1-25CVGS-30-760 | | | 3-phase Type 2 surge protector - Uc : 760V |DAC50S-30-760 | | | 3-phase Type 2 surge protector - Uc : 800V |DAC50S-31-760-2600DC | 2 - 690 V | | Description | Model | | --- | ---- | --- | | | Type 2+3 surge protector - Uc : 1260V |DACN30VGS-30-1260 | | | Type 2 surge protector - Uc : 1100V |DS41S-1000 | 3 - Datalines | | Description | Model | | --- | ---- | --- | | | 1-pair Telecom-Data surge protector - DIN rail mounting - Ultra compact |
DLC
-24D3/RE | | | RJ45 surge protector for POE++ networks |MJ8-POE-A-SD | 4 - Counter | | Description | Model | | --- | ---- | --- | | | Lightning monitoring system for windturbines |LMS-W |
Download Windturbine flyer
PDF Found
DLC-170
No result found