Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
LED
Standard surge protection plate/wall
MLP1-230L-W
Surge protector for LED lighting system Class 1
MLP1-230L-W
Part Number
711211
Specially developed spd with combined protection for 2-phase power supply (control phase):
Many variants available depending on application
With screw terminals or cable wiring
IP65 versions
For protection class I or II application
Developed for Uoc: 10 kV and Imax: 10 kA for highest outdoor requirements according to IEEE & ANSI
Optical error signalling
Datasheet
Installation Sheet
Tender specifications
Contact Us
The MLP range is a comprehensive series of AC surge protectors dedicated to LED lighting system. Some versions are equipped with an extra dataline surge protection (RS485 or DALI) in order to provide a full solution for LED systems with transmission features. By this way the MLP range is able to provide all the existing configurations with an efficient solution . MLP surge protectors are based on a powerful association of MOV and GDT components, able to protect LED system against huge surges without disconnection. In the worse case, the SPD will fail in safety condition. Indication of the SPD failure is performed through power supply cut off and/or through remote signaling feature.
Select another reference:
MLP1-230L-W
MLP1-230L-W-2L
MLP1-230L-W/RS
MLP2-230L-W-2L
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2+3
Isolation classe
I
Network
220-240 V Single-phase
AC system
TT-TN
Nominal line voltage
Un
230-277 Vac
Max. AC operating voltage
Uc
305 Vac
Max. frequency
f max.
10 MHz
Max. load current
@25°C
IL
2.5 A
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac disconnection
Residual Current
Leakage current to Ground
Ipe
None
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
5 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
10 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
20 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
10 kV / 5 kA
Withstand on overvoltages IEEE C62.41.1
10 kV / 10 kA
Protection mode(s)
Common/Differential mode
Protection level L/N
@ In (8/20µs)
Up L/N
1.5 kV
Protection level L/PE
@ In (8/20µs)
Up L/PE
1.5 kV
Admissible short-circuit current
Isccr
10 000 A
Technology
MOV+GDT
Connection to Network
By screw terminal: 1.5mm² max.
Mounting
On plate
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP65
Failsafe mode
Disconnection and AC line cut-off
Disconnection indicator
LED green OFF and AC network cut-off
Voltage/operating indicator
Green Led ON
Remote signaling of disconnection
No
Dimensions
See diagram
Weight
0.109 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
×
Description:
Surge protector for LED lighting system Class 1
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Technology:
MOV+GDT
Remote signaling of disconnection:
No
SPD type :
2+3
Network:
220-240 V Single-phase
AC system:
TT-TN
Max. AC operating voltage :
305 Vac
Residual Current :
None
Max. discharge current :
10 kA
Total Maximum discharge current :
20 kA
Admissible short-circuit current:
10 000 A
CITEL
Reference:
MLP1-230L-W
Part Number:
711211