Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
LED
POP
MLPVM2-230L-5A
Protection against Surge, Temporary and Permanent overvoltages for Class II LED lighting system
MLPVM2-230L-5A
Part Number
832278
Protection against all types of overvoltages
For Class II Led lighting
230 V single-phase network / 5 A
Function 'Surge voltage protection' (SPD)
Surges due to lighting or switching
Function 'Permanent or temporary overvoltage protection' (POP)
Datasheet
CITEL_Certif_EU_MLPVM.pdf
Installation Sheet
Tender specifications
Contact Us
The MLPVM has been designed to protect single-phase Class 2 equipment. This product offers protection against transient overlvoltage and a protection against temporary and permanent overvoltage on the network. The MLPVM complies IEC 61643-11 standards. The MLPVM offers a very good power ratio with a discharge capacity of 10 kA and a very compact format. The installation of the product is done via its spring terminals.
Select another reference:
MLPVM2-230L-5A
Electrical Properties
Mechanical Properties
Norms
Schemas
Isolation classe
II
Network
230 V single-phase
AC system
TT-TN
Max. AC operating voltage
Uc
255 Vac
Max. load current
@25°C
IL
5 A
Residual Current
Leakage current to Ground
Ipe
None
Nominal discharge current
15 x 8/20 µs impulses
In
5 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
10 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
10 kV
Withstand on overvoltages IEEE C62.41.1
10 kV / 10 kA
Protection mode(s)
L/N
Protection level L/N
@ In (8/20µs)
Up L/N
1.5 kV
Admissible short-circuit current
Isccr
10 000 A
Connection to Network
In series by conductors 1.5mm² - spring terminal
Mounting
On plate
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Insulation class
Classe 2
Failsafe mode
Disconnection and AC line cut-off
Disconnection indicator
Green LED OFF and line cut off
Voltage/operating indicator
Green Led ON
Dimensions
See diagram
Weight
0.040 kg
Standards compliance
EN 61643-11 / IEC 61643-11
Certification
×
Description:
Protection against Surge, Temporary and Permanent overvoltages for Class II LED lighting system
Standards compliance:
EN 61643-11 / IEC 61643-11
Certification:
EAC
Network:
230 V single-phase
AC system:
TT-TN
Max. AC operating voltage :
255 Vac
Residual Current :
None
Max. discharge current :
10 kA
Admissible short-circuit current:
10 000 A
CITEL
Reference:
MLPVM2-230L-5A
Part Number:
832278
Or equivalent