1-pair Data surge protector
Part Number: 831611
MDL-28-R
- Data line protection
- High energy protection in common-mode
- Low clamping level in differential mode
- Galvanic isolation to earth connection
- Indoor applications, IP20 (NEMA 2)
- Plastic enclosure, UL94-V0
- Certified acc. to IEC/EN 61643-21
- Location and test categories: C2, C3
MDL compact surge protective devices (SPDs) are designed to protect the DALI control-lines of lighting systems, typically used in tunnel applications, from the effects of lightning and transient over voltages.
These SPDs are installed on mounting plates, typically within the luminaires itself or in the lighting cabinets. MDL SPDs protect 1-pair (2-wire) lines and feature a compact non-pluggable (monobloc) enclosure based on Citels' well-known MLPC series shape.
The hybrid protection circuit combining a gas discharge tube and clamping diodes offers a full-mode protection across the data-lines by additionally providing specific protection for the signalling ground wire (where needed).
Select another reference:
MDL-28-R
Certificates
|
Network
|
Digital communication (2-Wire) |
|
|
Protection modes (network)
|
CM / DM |
|
|
Lightning Protection Zones (LPZ)
|
1 - 3 |
|
|
Nominal line voltage
|
Un | 24 Vdc |
|
Max. DC operating voltage
|
Uc | 28 Vdc |
|
Cut-off frequency
-3dB, 100 ohm system
|
f max. | > 30 MHz |
|
Cut-off frequency
-1dB, 100 ohm system
|
f max. | > 10 MHz |
|
Max. load current @25°C
|
IL | 500 mA |
|
Signal rise/fall times, to BS EN IEC 62386-101:2022
|
tʳⁱˢᵉ, tᶠᵃˡˡ | 3 µs |
|
Nominal discharge current
C2 (1.2/50us / 8/20µs), 10 applications X-C (Line/Earth)
|
In | 4 kV / 2 kA |
|
Nominal discharge current
CWG (1.2/50us / 8/20us) with 42 ohms, X-X (Line-Line),
to IEC 61000-4-5 (unshielded asymmetric)
|
In | 800 V / 20 A |
|
Max. discharge current
C2 (1.2/50µs / 8/20µs), 10 applications, X-C (Line-Earth)
|
20 kV / 10kA |
|
|
Protection Level
C3 (10/1000μs), 300 applications@10 A, Y-Y (Line/Line)
|
Up | < 40 V |
|
Protection Level
C2 (1.2/50µs / 8/20µs), 10 applications, Y-C (Line-Earth)
|
Up | < 1000 V |
|
Protection Level
CWG (1.2/50µs / 8/20µs) with 42 ohms, Y-Y (Line-Line),
to IEC 61000-4-5 (unshielded asymmetric)
|
Up | < 48 V |
|
Line resistance (± 10%)
|
< 0.2 ohms |
|
|
Capacitance
@1MHz X-C (Line/Earth)
|
C | < 10 pF |
|
Capacitance
@1MHz X-X (Line-Line)
|
C | < 30 pF |
|
Technology
|
GDT+TVS diode |
|
|
SPD configuration
|
Data-pair, plus PE |
|
|
Connection to Network
|
2 spring terminals opposite side in/out - wire 1.5mm² max. |
|
|
Format
|
Plastic Enclosure with connectors input/output |
|
|
Mounting
|
On plate |
|
|
Housing material
|
Thermoplastic UL94 V-0 |
|
|
Operating and storage temperature
|
-40/+85°C |
|
|
Ingress Protection rating
|
IP20 (NEMA 2) |
|
|
Failsafe mode
|
Transmission cut-off - Fault mode 2 (short-circuit) |
|
|
Dimensions
|
See diagram |
|
|
Weight
|
0.035 kg / 0.09 lbs |
|
Standards compliance
|
IEC 61643-21 / EN 61643-21/ IEC 61000-4-5 / IEC 62386-101 |
|
|
Certification
|
KEMA |