Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 2 AC surge protector
DS74R-400/G
Type 2 AC surge protector - 3-phase
DS74R-400/G
Part Number
491412
Discover our latest innovation : the
DAC80-31-440
Re-inforced Type 2 AC surge protector
In : 30 kA
Imax : 70 kA
Pluggable module by phase
Remote signaling
IEC 61643-11, EN 61643-11 compliance
UL1449 ed.5 approved
Datasheet
Installation Sheet
Tender specifications
Contact Us
DS70R type 2 AC surge protector are used mainly for primary protection of single and three-phase networks at the main electrical panel. They provide common-mode protection and are available in one-phase, single-phase, 3-phase and 3-phase+Neutral. This SPD is based on association of high energy varistors equipped with thermal disconnector and failure indicator, to comply with standards. The DS70R surge protectors are designed to be used in a multipolar configuration to protect single-phase, 3-phase or 3-phase+N AC networks. Each pole of the SPD is connected between Line(s) and PE and Neutral and PE.
Select another reference:
DS74R-400/G
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2
Network
230/400 V 3-phase+N
AC system
TT-TNS
Nominal line voltage
Un
230 Vac
Max. AC operating voltage
Uc
440 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
580 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
770 Vac disconnection
Temporary Over Voltage N/PE (TOV HT)
Without disconnection or with safety disconnection
UT
1200 V/300A/200 ms withstand
Residual Current
Leakage current to Ground
Ipe
None
Operating current
Continious current at Uc
Ic
< 1 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
30 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
70 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
70 kA
Connection mode(s)
L/N and N/PE
Protection mode(s)
Common/Differential mode
Protection level L/N
@ In (8/20µs)
Up L/N
1.8 kV
Protection level N/PE
@ In (8/20µs)
Up N/PE
1.5 kV
Admissible short-circuit current
Isccr
25 000 A
Response time L-N
25 ns
Technology
MOV
SPD configuration
3-phase+Neutral
Connection to Network
By screw terminals: 2.5-25mm² / by bus
Format
Plug-in modular box
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-2
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
2 mechanical indicators by pole
Spare module(s)
DSM70R-230 + DSM70G-600
Remote signaling of disconnection
Output on changeover contact
Dimensions
See diagram
Weight
0,45
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
100 A min. - 125 A max. - Fuses type gG
×
Description:
Type 2 AC surge protector - 3-phase
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
EAC
Technology:
MOV
SPD configuration:
3-phase+Neutral
Remote signaling of disconnection:
Output on changeover contact
SPD type :
2
Network:
230/400 V 3-phase+N
AC system:
TT-TNS
Max. AC operating voltage :
440 Vac
Residual Current :
None
Max. discharge current :
70 kA
Total Maximum discharge current :
70 kA
Admissible short-circuit current:
25 000 A
CITEL
Reference:
DS74R-400/G
Part Number:
491412
Or equivalent