Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 1+2 AC surge protector
DAC1-13-31Y-880
Type 1+2 3-phase AC surge protector for PV inverter
DAC1-13-31Y-880
Part Number
821750534
Availability:
€317.00 (excl. tax)
Add to cart
Shipping is only available to France.
OK
Available within 3 weeks
Type 1 + 2 3-Phase AC surge protector
up to 800 Vac voltage network
PV inverter application: Max DC voltage L/PE= 1200 Vdc
Iimp: 12.5 kA
Pluggable module
Remote signaling (option)
EN 61643-11, IEC 61643-11 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
1+2
Network
Equal or less than 800 Vac
AC system
TNC-IT
Max. AC operating voltage
Uc
880 Vac
Max. DC operating voltage
Uc
1200 Vdc
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
1160 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
1385 Vac disconnection
Residual Current
Leakage current to Ground
Ipe
< 1 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
50 kA
Impulse current by pole
max. withstand 10/350µs by pole
Iimp
12.5 kA
Specific energy by pole
max. withstand 10/350 µs
W/R
40 kJ/ohm
Protection level
@ In (8/20µs)
Up
3.4 kV
Admissible short-circuit current
Isccr
50 000 A
Network type
AC
SPD configuration
3-phase
Connection to Network
By screw terminals: 2.5-25mm² (35mm² rigid)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole - Red/Green
Spare module(s)
MDAC1-13-440
Remote signaling of disconnection
option DAC1-13S-31Y-800 : output on changeover contact
Dimensions
See diagram - 4TE (EN43880)
Weight
0.652 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
315 A max. - Fuses Type gG / or SFD1-25S
×
Description:
Type 1+2 3-phase AC surge protector for PV inverter
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
SPD configuration:
3-phase
Remote signaling of disconnection:
option DAC1-13S-31Y-800 : output on changeover contact
SPD type :
1+2
Network:
Equal or less than 800 Vac
AC system:
TNC-IT
Max. AC operating voltage :
880 Vac
Max. DC operating voltage:
1200 Vdc
Residual Current :
< 1 mA
Max. discharge current :
50 kA
Impulse current by pole :
12.5 kA
Protection level :
3.4 kV
Admissible short-circuit current:
50 000 A
CITEL
Reference:
DAC1-13-31Y-880
Part Number:
821750534
Or equivalent