Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Search
Product Selection
CMJ8-POE-A-PCB
CMJ8-POE-A-C5E
The
CMJ8
-
POE
is an outdoor
PoE
surge protector designed to protect sensitive data-processing equipment connected to a
PoE
(Power over Ethernet) network from transient over voltages. The
CMJ8
-
POE
surge protector is deployed in signal network applications with data transmission speeds up to1000 Mbps and is equipped with high quality shielded RJ45 connectors.
-
Discover our latest innovation : the
CWMJ8-
POE
-C6A
-
POE
++ compatible surge protector - Category 5E compatible - Shielded RJ45 connectors - Outdoor application: IP65 - Metal enclosure - Compliant with IEC 61643-21, NF EN 61643-21 - UL497B certified
Outdoor gigabit
POE
-A surge protector
POE
surge protector
CMJ8
-
POE
-
A
-C5E
CMJ8
Series Outdoor Gigabit
POE
SPD IEEE 802.3af 802.3at, 802.3btUp to 10Gbps
CMJ8
-
POE
-A-C5E/
PCB
CMJ8-POE-B-C5E
The
CMJ8
-
POE
is an outdoor
PoE
surge protector designed to protect sensitive data-processing equipment connected to a
PoE
(Power over Ethernet) network from transient over voltages. The
CMJ8
-
POE
surge protector is deployed in signal network applications with data transmission speeds up to1000 Mbps and is equipped with high quality shielded RJ45 connectors.
-
Discover our latest innovation : the
CWMJ8-
POE
-C6A
-
POE
++ compatible surge protector - Category 5E compatible - Shielded RJ45 connectors - Outdoor application: IP67 - Metal enclosure - Compliant with IEC 61643-21, NF EN 61643-21 - UL497B certified
Outdoor gigabit
POE
-B surge protector
POE
surge protector
POE
-B and Gigabit Ethernet, High
POE
CMJ8
-
POE
-B-C5E
CMJ8
Series Outdoor Gigabit
POE
SPD IEEE 802.3af 802.3at, 802.3btUp to 10Gbps
CMJ8
-
POE
-A-C5E/
PCB
CGMJ8-POE-B-C5
The
CMJ8
-
POE
is an outdoor
PoE
surge protector designed to protect sensitive data-processing equipment connected to a
PoE
(Power over Ethernet) network from transient over voltages. The
CMJ8
-
POE
surge protector is deployed in signal network applications with data transmission speeds up to1000 Mbps and is equipped with high quality shielded RJ45 connectors.
-
Discover our latest innovation : the
CWMJ8-
POE
-C6A
Outdoor gigabit
POE
-B surge protector
POE
surge protector
POE
-B and 100Mbit Ethernet, High
POE
CGMJ8-
POE
-B-C5
CMJ8
Series Outdoor Gigabit
POE
SPD IEEE 802.3af 802.3at, 802.3btUp to 10Gbps
CMJ8
-
POE
-A-C5E/
PCB
CRMJ8-POE-C6A
The CxMJ8-
POE
-C6A is an outdoor
PoE
surge protector designed to protect sensitive data-processing equipment connected to a
PoE
(Power over Ethernet) network cabling Category 6 and Ethernet 10Gigabit from transient overvoltages. ... The
CMJ8
-
POE
surge protector is deployed in signal network applications with data transmission speeds up to1000 Mbps and is equipped with high quality shielded RJ45 connectors.
-
POE
++ compatible surge protector - Category 6A compatible - Shielded RJ45 connectors - Outdoor application: IP67 - Metal case - Compliant with IEC 61643-21, NF EN 61643-21 - UL497B certified
Outdoor
POE
++ in-line surge protector
POE
surge protector
POE
++ and 10Gigabit Ethernet
CRMJ8-
POE
-C6A
CMJ8
Series Outdoor Gigabit
POE
SPD IEEE 802.3af 802.3at, 802.3btUp to 10Gbps
CRJ8-
POE
-C6A/
PCB
CWMJ8-POE-C6A
The new CWMJ8-
POE
-C6A product is designed to protect
POE
++ and Ethernet Category 6A networks. ... It completes the existing range of CITEL
PoE
surge protectors (CRMJ8-
POE
-C6A with metal enclosure, for outdoor application & MJ8-
POE
-C6A for indoor use). Based on hybrid diagram made with gas tubes and low capacitance clamping diodes, this surge protector is ideally suited for
PoE
-connected devices as IP cameras or WiFi hotspots.
-
POE
++ Compatible (IEEE 802.3bt) -10Gb (5-100m) with Cat6A S/FTP cabling - Shielded RJ45 connectors - Outdoor applications, IP66 (NEMA 4/4X) - Plastic enclosure, UL94-V0 - Conforms to IEC/EN 61643-21 - SPD categories D1, C3, C2, C1
10 gigabit
POE
++ surge protector
POE
surge protector
CWMJ8-
POE
-C6A
CMJ8
Series Outdoor Gigabit
POE
SPD IEEE 802.3af 802.3at, 802.3btUp to 10Gbps
PCH24-POE-A
- 19'' patch panel surge protector for
POE
-A - 24 ports - In : connector type 110 back - Out : RJ45 front - Maintenance possible per port - Secondary protection - UL497B
19'' patch panel surge protector -
POE
-A line
POE
mode A, Gigabit Ethernet,
POE
Plus
PCH24-
POE
-
A
MJ8-POE-A
The MJ8-
POE
is designed to protect sensitive data-processing equipment connected to a
POE
++ (Power over Ethernet) network from transient overvoltages. The MJ8-
POE
surge protector is deployed in signal network applications with data transmission speeds of 100 and 1000 Mbps.
-
POE
++ Compatible (IEEE 802.3bt) - 1Gb (5-100m) with Cat6A S/FTP cabling - Shielded RJ45 connectors - Indoor applications, IP20 (NEMA 2) - Metallic enclosure - Conforms to IEC/EN 61643-21 - SPD categories D1, C3, C2, C1
Surge protector for
POE
++ and Category 6A cabling network
POE
surge protector
MJ8-
POE
-
A
MJ8-
POE
MJ8-
POE
Series for IEEE 802.3af, 802.3at, 802.3btUL497BCAT6A,CAT6, CAT5e, CAT5
PCH48-POE-A
- 19'' patch panel surge protector for
POE
-A - 48 ports - In : connector type 110 back - Out : RJ45 front - Maintenance possible per port - Secondary protection - UL497B
19'' patch panel surge protector -
POE
-A line
POE
mode A, Gigabit Ethernet,
POE
Plus
PCH48-
POE
-
A
RAK16-POE-A
The RAK series of rack mount and wall mount standoff protectors will ensure the reliable operation of networked equipment connected to 10/100/1000BaseT Ethernet, Cat5, Cat6,
PoE
and most other communication interfaces.
- 19'' patch panel surge protector for
POE
-A - mounting 'stand-alone' - 16 ports - In/Out front : RJ45 -Maintenance possible per port - Secondary Protection - Conforme UL497B
POE
mode A, Gigabit Ethernet,
POE
Plus
RAK16-
POE
-
A
PCH12-POE-A
- 19'' patch panel surge protector for
POE
-A - 12 ports - In : connector type 110 back - Out : RJ45 front - Maintenance possible per port - Secondary protection - UL497B
19'' patch panel surge protector -
POE
-A line
POE
mode A, Gigabit Ethernet,
POE
Plus
PCH12-
POE
-
A
RAK32-POE-A-SO
The RAK series of rack mount and wall mount standoff protectors will ensure the reliable operation of networked equipment connected to 10/100/1000BaseT Ethernet, Cat5, Cat6,
PoE
and most other communication interfaces.
- 19'' patch panel surge protector for
POE
-A - mounting 'stand-alone' - 32 ports - In/Out front : RJ45 -Maintenance possible per port - Secondary Protection - Conforme UL497B
POE
mode A, Gigabit Ethernet,
POE
Plus
RAK32-
POE
-
A
-SO
MJ8-POE-A/SD
MJ8-
POE
-A/SD is designed with more stronger mounting DIN-Rail bracket for fitting vibration environment like wind turbines. This product protect sensitive data-processing equipment connected to a
POE
++ (Power over Ethernet) network from transient overvoltages, is deployed in signal network applications with data transmission speeds of 100 and 1000 Mbps.
-
POE
++ compatible - Strong mounting for DIN-rail for vibration enviroments - Gigabit Ethernet (Cat.5E) - Shielded enclosure and connectors - 2 kA discharge capability - IEC 61643-21, EN 61643-21 compliance
RJ45 surge protector for
POE
++
MJ8-
POE
-
A
/SD
MJ8-
POE
-
A
/SD
MJ8-
POE
-A/SD Series
POE
++ Surge protector Gigabit Ethernet (Cat.5E)
MSP-VM12/R
MSP-VM-R Series
POE
Injector or Splitter 24Vdc to 48Vdc Non-
POE
+
POE
networks
POE
Network
MSP-VM230/R
MSP-VM-R Series
POE
Injector or Splitter 24Vdc to 48Vdc Non-
POE
+
POE
networks
POE
Network
MSP-VM24/R
MSP-VM-R Series
POE
Injector or Splitter 24Vdc to 48Vdc Non-
POE
+
POE
networks
POE
Network
MSP-VM120/R
MSP-VM-R Series
POE
Injector or Splitter 24Vdc to 48Vdc Non-
POE
+
POE
networks
POE
Network
MSP-VM48-RINJ
- Security camera surge protector - Combined
POE
Mid-Span Injector or Splitter and SPD - Supports 802.3af, 802.3at, 802.3bt (
POE
++) - Compact aluminum housing - DIN Rail mounting or plate - Integrated power supply injector connector (power supply separate)
MSP-VM-R Series
POE
Injector or Splitter 24Vdc to 48Vdc Non-
POE
+
POE
networks
POE
Network
MJ8-POE-B
The MJ8-
POE
is designed to protect sensitive data-processing equipment connected to a
POE
(Power over Ethernet) network from transient overvoltages. The MJ8-
POE
surge protector is deployed in signal network applications with data transmission speeds of 100 and 1000 Mbps.
-
POE
++ compatible (IEEE 802.3bt) - 10G compatible from 5m to 100m in the channel, using Cat-6A S/FTP cabling - RJ45 Shielded connectors - IEC 61643-21, EN 61643-21 - Indoor application: IP20 rating (NEMA 2) - Plastic enclosure, UL94-V0 - Location and test categories: D1, C2, C3
Surge protector for
POE
++ and Category 6A cabling network
POE
surge protector
POE
-B and Gigabit Ethernet, High
POE
MJ8-
POE
-B
MJ8-
POE
MJ8-
POE
Series for IEEE 802.3af, 802.3at, 802.3btUL497BCAT6A,CAT6, CAT5e, CAT5
Range Selection
CMJ8-POE-A-PCB
Range MJ8-POE-A/SD - MJ8-POE-A/SD
Range MJ8-POE - MJ8-POE-A
Range DAC40C Single Phase - DAC40C-11-150
Range DAC15CS Single Phase - DAC15CS-11-150
Range DAC15C Single Phase - DAC15C-11-150
Range DAC40C 3-Phase - DAC40C-30-150
Range DAC40CS 3-Phase - DAC40CS-30-150
Range DAC15C 3-Phase - DAC15C-30-150
Range DAC15CS 3-Phase - DAC15CS-30-150
Range DAC40CS Single Phase - DAC40CS-11-150
Range Cartouches de remplacement BT - DSM10-400
Range Cartouches de remplacement PV - DSM50PV-1000G/51
Range ZPAC1 - ZPAC1-13VG-31-275
Range PAC - PAC25S-10-150
Range MLPCA - MLPCA1-230L
Range DACN10-L - DACN10-L11-150
Range DLAS - DLAS-06D3/R
Range DLAH - DLAH-06D3
Pages
CMJ8-POE-A-PCB
CITEL, surge protectors for security systems
. Selection of SPDs for Security Systems 1 - Surge Protectors for Survey Cameras | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Anolog Camera | MSP-VM230-2P | Combined surge protectors | | | IP Cameras | CRMJ8-
POE
-C6A |
POE
++ and 10 Gigabit Ethernet | | | Coaxial lines as Video-transmission | CXC06-B/FM | Coaxial surge protector, BNC connector | | | 10Gigabit Ethernet/
POE
++ networks | MJ8-
POE
-C6A | Ethernet surge protector, Shielded RJ45 connections on Cat6A cabling | | | 10Gigabit Ethernet | MJ8-C6A | Ethernet surge protector, Shielded RJ45 connections on Cat6A cabling | |
2 - Surge Protectors for Control Rooms | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Control room | RAK16-E-C6 | 19" Rack surge protector - 10/100/1000BaseT networks | |
3 - Surge Protectors for Main Electrical Panel | Location | Citel models | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | AC network - Main switchboard | DAC1-13S-31-275 | Type 1+2+3 surge protector 3-phase+N | |
4 - Surge Protectors for fire Alarm | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Fire alarm | DAC40CS-11-275 | Type 2 (or 3) surge protector - Compact - Single phase | | | Fire alarm | DAC40CS-31-275 | Type 2 (or 3) surge protector - Compact - 3-phase | |
5 - Surge Protector for Acces Control | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Access control | DLA | Dataline surge protectors - DIN rail mounting | |
6 - Surge Protector for LED Lighting | Location | Citel model | Type of SPDs | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Inside the cutouts of led lighting pole | DLPM1-230L | 230 V single phase surge protector - DIN rail mounting | |
| --- | --- | |
Download flyer
|
Watch video
| | | |
Technical note: PPV-PAC series
One solution for this is the use of lightning and surge arresters that can be soldered directly to a printed circuit board (
PCB
). In contrast to conventional devices which are mounted on a DIN rails, this means that only a fraction of the space is required. ... The single-pole protective devices are soldered onto
PCBs
, which means that any configuration (Y circuit, L circuit, delta circuit, etc.) can be realised. ... Furthermore, all units of the PPV and PAC series have the same PinOut, which makes it easy to change from type 1 to type 2 or vice versa, as well as to change to a different voltage without adapting the
PCB
Key points - PV and AC versions - Combination arrestor T1 + T2 or SPD T2 - Iimp up to 6.25 kA (10/350) - Imax up to 40 kA (8/20) - Optical failure signalling - Remote signalling as standard - Same pin-out for all variants - Rated voltages up to Un = 1,000 Application example See products | | Models | | --- | ---| | | PPV series | | | PAC series |
Citel, Water Waste Treatment
Implementation of coordinated system of protection against transient overvoltages |--- | --- | --- | --- | | Number | Location | Models | | 1 | AC power - Main electrical panel | DAC1-13VGS-31-275 | | | 1 | | DS254VG-300/G | | | 2 | Coaxial antenna - Radio wireless | P8AX | | | 3 | AC power - Distribution panel | DAC40CS-31-275 | | | 4 et 5 | Control circuit - Remote management | DAC15CS-31-275 | | 6 | Telecom-Data-Ethernet | DLA | | | 6 | | MJ8-
POE
-C6A | | | 7 | Control room | DAC50S-31-275 | | | 7 | | MJ8-
POE
-C6A | | | 7 | | DLA | | | --- | | Download flyer | | |
Surge Protection for Wind Turbine installation
. Selection of SPDs
1 - 230V / 400 V | | Description | Model | | --- | ---- | --- | | | Type 1+2+3 surge protector - VG Technology - Uc : 760V |DACN1-25CVGS-30-760 | | | 3-phase Type 2 surge protector - Uc : 760V |DAC50S-30-760 | | | 3-phase Type 2 surge protector - Uc : 800V |DAC50S-31-760-2600DC | 2 - 690 V | | Description | Model | | --- | ---- | --- | | | Type 2+3 surge protector - Uc : 1260V |DACN30VGS-30-1260 | | | Type 2 surge protector - Uc : 1100V |DS41S-1000 | 3 - Datalines | | Description | Model | | --- | ---- | --- | | | 1-pair Telecom-Data surge protector - DIN rail mounting - Ultra compact |DLC-24D3/RE | | | RJ45 surge protector for
POE
++ networks |MJ8-
POE
-A-SD | 4 - Counter | | Description | Model | | --- | ---- | --- | | | Lightning monitoring system for windturbines |LMS-W |
Download Windturbine flyer
Citel, SPDs for Energy Storage System ESS
. Surge Protectors selection
| Location | | Description | Model | | --- | --- | ---- | --- | | DC Battery protecgtion | | Kit ESS: 1500Vdc surge protector + Fusible |KIT ESS DDC50S-21Y-1500 | | Main Electrical Panel | | Type 1+2+3 AC surge protector 3-phase+N |DAC1-13VGS-31-275 | | Main Electrical Panel | | Fuse + Holders for 3-phase+N surge protector |SFD1-13S-31 | | Secondary panel | | Type 2 AC surge protector 3-phase+N |DACF25S-31-275 | | Control Sytems | | 1-pair Data surge protector pluggable |DLA-24D3 | | Control Systems | |
POE
++ and Cat.6A surge protector |MJ8-
POE
-C6A | | Connected PV site | | Type 2 PV surge protector 1500Vdc |DPVN40CVGS-21Y-1500 | | Windturbines | | Type 1+2+3 AC surge protector single-phase|DACN1-25VGS-10-440 |
| --- | |
Download flyer
| | |
Effects of lightning
Overvoltages have many types of effects on electronic equipment; in order of decreasing importance: Destruction - Voltage breakdown of semiconductor junctions - Destruction of bonding of components - Destruction of tracks of
PCBs
or contacts - Destruction of triacs/thyristors by dV/dt.
PDF Found
CMJ8-POE-A-PCB
CMJ8-POE__E_F130401B.pdf
.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail: contact@citel.fr • www.citel.fr DBCP LISTED
CMJ8
-
POE
-
A
CMJ8
-
POE
-
A
/
PCB
140 113 112 80 Ficha Técnica Características F130401B • Reservado el derecho modificaciones de este documento P : Descargador de gas tripolar DBC : 3-pole Diodo baja capacidad Línea Equipo Protección
POE
para uso exterior
CMJ8
-
POE
• Versión
POE
• Para uso en exterior • Cajas de plástico • IP65 y IP66 • Conectores RJ45 blindados • Capacidad de descarga : 2 kA • UL497B Referencias CITEL C*MJ8-
POE
-
A
-C5E C*MJ8-
POE
-B-C5E Designación Protección
POE
-
A
para uso exterior Protección
POE
-B para uso exterior Red
POE
-
A
y Gigabit Ethernet, high
POE
POE
-B y Gigabit Ethernet, high
POE
Velocidad máx. 1000 Mbps 1000 Mbps Configuración protección 8 hilos + blindaje 8 hilos + blindaje Pin out (1-2)(3-6)(4-5)(7-8) (1-2)(3-6)(4-5)(7-8) Tensión nominal de línea Un 48 Vdc 5 Vdc/48 Vdc Tensión DC máx. de operación Uc 60 Vdc - 650 mA 7.5 Vdc (1.2.3.6) - 650 mA. 60 Vdc (4.5.7.8) - 650 mA Corriente máx. de línea IL 1200 mA 1200 mA Frecuencia máx. f max > 100 MHz > 100 MHz Perdida de inserción < 1 dB < 1 dB Corriente de descarga nominal Línea/Tierra Prueba 8/20µs x 10 - categoria C2 In 2000
A
2000
A
Corriente de descarga nominal Línea/Línea Prueba 8/20µs x 10 - categoria C2 In 500
A
500
A
Corriente de choque Prueba 10/350µs x 2 - categoria D1 Iimp 500
A
500
A
Nivel de protección Up 70 V 20/70 V Final de vida Corto-circuito Corto-circuito Características mecánicas Módulo de repuesto
CMJ8
-
POE
-
A
-C5E/
PCB
CMJ8
-
POE
-B-C5E/
PCB
Dimensiones ver esquema Formato Caja plástica con conectores entrada/salida Conexión
a
la red conector blindaje RJ45 hembra entrada/salida Indicador de desconexión interrupción de transmisión Montaje sobre pletina o poste Temperatura de operación -40/+85°C Uso exterior si Material de la caja Termoplástico UL94-V0 Conformidad con las normas IEC 61643-21 / EN 61643-21 / UL497B IEEE 802-3ab/3at Código Versión IP65
CMJ8
-
POE
-
A
-C5E 892002
CMJ8
-
POE
-B-C5E 892003 Versión IP66 (estanqueidad reforzada) CGMJ8-
POE
-
A
-C5E 892004 CGMJ8-
POE
-B-C5E 892005
CMJ8-POE__A_F100202G.pdf
.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail: contact@citel.fr • www.citel.fr DBCP LISTED
CMJ8
-
POE
-
A
CMJ8
-
POE
-
A
/
PCB
140 113 112 80 Data Sheet Characteristics F100202G • Document could be modified without notice P : 3-electrode gas tube DBC : 3-pole Low capacitance diode Line Equipment Outdoor gigabit
POE
surge protector
CMJ8
-
POE
•
POE
compatible • Outdoor application • Plastic enclosures • IP65 and IP66 • Shielded RJ45 connectors • 2 kA discharge capability • UL497B CITEL Model C*MJ8-
POE
-
A
-C5E C*MJ8-
POE
-B-C5E Description Outdoor gigabit
POE
-
A
surge protector Outdoor gigabit
POE
-B surge protector Network
POE
-
A
and Gigabit Ethernet, high
POE
POE
-B and Gigabit Ethernet, high
POE
Max. data rate 1000 Mbps 1000 Mbps SPD configuration 8 wires + shielded 8 wires + shielded Pin outs (1-2)(3-6)(4-5)(7-8) (1-2)(3-6)(4-5)(7-8) Nominal line voltage Un 48 Vdc 5 Vdc/48 Vdc Max. ... Load current IL 1200 mA 1200 mA Max. frequency f max > 100 MHz > 100 MHz Insertion loss < 1 dB < 1 dB Line/Ground Nominal discharge current 8/20µs Test x10 - C2 category In 2000
A
2000
A
Nominal discharge current Line/Line 8/20µs Test x10 - C2 category In 500
A
500
A
Impulse current - 2 x 10/350µs Test - D1 Category Iimp 500
A
500
A
Protection level Up 70 V 20/70 V Failsafe behavior Short-circuit Short-circuit Mechnical characteristics Spare unit
CMJ8
-
POE
-
A
-C5E/
PCB
CMJ8
-
POE
-B-C5E/
PCB
Dimensions see diagram Format Plastic Box with connectors input/output Connection to Network RJ45 shielded connectors female input/output Disconnection indicator transmission interrupt Mounting on plate or pole Operating temperature -40/+85°C Outdoor use yes Housing material Thermoplastic UL94-V0 Standards compliance IEC 61643-21 / EN 61643-21 / UL497B IEEE 802-3ab/3at Part number IP65 version
CMJ8
-
POE
-
A
-C5E 892002
CMJ8
-
POE
-B-C5E 892003 IP66 version (reinforced seal) CGMJ8-
POE
-
A
-C5E 892004 CGMJ8-
POE
-B-C5E 892005
CMJ8-POE__F_F120205D.pdf
.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail: contact@citel.fr • www.citel.fr DBCP LISTED
CMJ8
-
POE
-
A
CMJ8
-
POE
-
A
/
PCB
140 113 112 80 Fiche Technique Parafoudre extérieur pour
POE
(Power Over Ethernet) Gamme
CMJ8
-
POE
Caractéristiques F120205D • Document sujet à modification sans préavis P : Eclateur à gaz tripolaire DBC : Diode basse capacité Ligne Equipement • Pour liaisons
POE
• Pour application extérieure • Boîtiers plastique • IP 65 et IP 66 • Connecteurs RJ45 blindés • Courant de décharge 2 kA • Homologué UL497B Référence CITEL C*MJ8-
POE
-
A
-C5E C*MJ8-
POE
-B-C5E Description Parafoudre extérieur pour réseaux
POE
-
A
Parafoudre extérieur pour réseaux
POE
-B Réseau
POE
-
A
et Gigabit Ethernet, High
POE
POE
-B et Gigabit Ethernet, High
POE
Débit maximal 1000 Mbps 1000 Mbps Configuration 8 fils + blindage 8 fils + blindage brochage (1-2)(3-6)(4-5)(7-8) (1-2)(3-6)(4-5)(7-8) Tension nominale de ligne Un 48 Vdc 5 Vdc/48 Vdc Tension et Courant max Uc 60 Vdc - 650 mA 7.5 Vdc (1.2.3.6) - 650 mA. 60 Vdc (4.5.7.8) - 650 mA Courant max de ligne IL 1200 mA 1200 mA Frequence max d’utilisation f max > 100 MHz > 100 MHz Perte d’insertion - @ fmax < 1 dB < 1 dB Courant de décharge nominal Ligne/Terre Test 8/20µs x 10 - catégorie C2 In 2000
A
2000
A
Courant de décharge nominal Ligne/Ligne Test 8/20µs x 10 - catégorie C2 In 500
A
500
A
Courant de choc - Test 10/350µs x 2 - catégorie D1 Iimp 500
A
500
A
Niveau de protection Up 70 V 20/70 V Mise hors service de sécurité court-circuit court-circuit Caractéristiques mécaniques Circuit de remplacement
CMJ8
-
POE
-
A
-C5E/
PCB
CMJ8
-
POE
-B-C5E/
PCB
Dimensions voir schéma Format Boitier plastique avec connecteurs entrée/sortie Raccordement au réseau connecteur blindé RJ45 femelle en entrée/sortie Fin de vie interruption de transmission Montage sur platine ou sur poteau Température de fonctionnement -40/+85°C Installation extérieure oui Boîtier Thermoplastique UL94-V0 Conformité aux normes IEC 61643-21 / EN 61643-21 / UL497B IEEE 802-3ab/3at Code Article version IP65
CMJ8
-
POE
-
A
-C5E 892002
CMJ8
-
POE
-B-C5 892003 version IP66 (étanchéité renforcée) CGMJ8-
POE
-
A
-C5 892004 CGMJ8-
POE
-B-C5 892005
I_CRMJ8-POE-C6_&_C6A_N200204b.pdf
Load current (IL) Cat5 / Cat6 Cat5 / Cat6 /Cat6A 1.2
A
2
A
Mechanical Characteristics Replace complete protector unit or replace internal
PCB
and RJ45 connectors. X Input Output CRMJ8-
POE
-C6
POE
A
& B Surge Protector Input Output N200204b Input Output
POE
input Toward
POE
equipment PE Input Output Power + Ethernet = OK Min. pole size Max. pole size * 5 cm 20 cm If
a
larger pole diameter is used then use two pole kits in series *
POE
input Toward
POE
equipment PE Input Output P/N 1.97 inch 7.88 inch Fit protector as close as possible to the
POE
cable entry point into the building ** DEFECTIVE 13100 ft max. 4000 m max... Humidity range 5% to 95%
CMJ8
-
POE
-C6/
PCB
or
CMJ8
-
POE
-C6A/
PCB
10 Gigabit Ethernet - CAT6A
POE
and Gigabit Ethernet 1000 Mbps 60 Vdc Ref. : CR-WM-KIT Code : 581532 Ref. : CR-PM-KIT Code : 581531 page SAFETY INSTRUCTIONS CONSIGNES DE SECURITE SICHERHEITSHINWEISE ADVERTENCIA DE SEGURIDAD AVVERTENZE IMPORTANTI WSKAZÓWKI BEZPIECZEŃSTWA VARNOSTA NAVODILA VEILIGHEIDSVOORSCHRIFTEN BEZPEČNOSTNÉ POKYNY SIKKERHEDSANVISNINGER SÄKERHETSANVISNINGAR AVISOS IMPORTANTES МЕРЫ БЕЗОПАСНОСТИ BEZPEČNOSTNÍ POKYNY 安全须知 WARNUNG ! ... - Svodič přepětí musí být vybrán podle aplikace
a
napěťové úrovně (tabulka 1). - Je-li signál přerušen, je svodič přepětí vadný
a
musí výt vyměněn.