Contact : +33 1 41 23 50 30 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
Webinars
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Search
Product Selection
B480-24D3
B480-24D3
The
B480
units are designed to protect terminals connected to telephone or data networks.
B480
-
24D3
B480
B480
Series Signal Line SPD 4 pair, 12V to 170V DC
S480-
24D3
DLATS-24D3
Stopped production - REPLACED BY: DLATS1-
24D3
(6417031)
DLATS-
24D3
DLAMTS-
24D3
DLC-24D3/RE
DLC-
24D3
/RE
DLC-
24D3
/RE
DLC-
24D3
/RE Series Telecom/Data protection 1 pair, Compact
B480-06D3
The
B480
units are designed to protect terminals connected to telephone or data networks.
B480
-06D3
B480
B480
Series Signal Line SPD 4 pair, 12V to 170V DC
B480-T
The
B480
units are designed to protect terminals connected to telephone or data networks.
B480
-T
B480
B480
Series Signal Line SPD 4 pair, 12V to 170V DC
B480-48D3
The
B480
units are designed to protect terminals connected to telephone or data networks.
B480
-48D3
B480
B480
Series Signal Line SPD 4 pair, 12V to 170V DC
B480-12D3
The
B480
units are designed to protect terminals connected to telephone or data networks.
B480
-12D3
B480
B480
Series Signal Line SPD 4 pair, 12V to 170V DC
DLAW-24D3
DLAW-
24D3
DLAM-
24D3
DLU2-24D3
DLU2-
24D3
DLATS1-24D3
DLATS1-
24D3
DLATS1M-
24D3
DLC-24D3
DLC-
24D3
DLA2-24D3
DLA2-
24D3
DLA2M-
24D3
DLU-24D3
DLU-
24D3
B180-24D3
B180-
24D3
S180-
24D3
DLAH-24D3
DLAH-
24D3
DLAHM-
24D3
DLAWTS1-24D3
DLAWTS1-
24D3
DLAWTS1M-
24D3
DLAS-24D3
DLAS-
24D3
DLASM-
24D3
B280-24D3
B280-
24D3
S280-
24D3
Range Selection
B480-24D3
Range B480 - B480-06D3
Range DLC-24D3/RE - DLC-24D3/RE
Pages
B480-24D3
CITEL, surge protectors for data center
|Position | | Description | Model | | --- | --- | ---- | --- | | 1 | | Compact Type 2 surge protector 3-phase+N |DAC40CS-31 | | 2 | | Rack 19" protection | RAK16-E-C6 | | 3 | | CAT5 - CAT6 surge protection | MJ8-C6A | | 4 | | Type 1+2+3 AC surge protector 3-phase+N | DAC1-13VGS-31 | | 5 | | 1-pair Din rail plug-in data surge protector| DLA-
24D3
|
Citel, surge protection for radiocom site
. Selection of SPDs |Position | | Description | Model | | --- | --- | ---- | --- | | 1 | | 'Quarter Wave' Coaxial SPD type 7/16 |PRC1800-716/MF | | 2 | | Type 1 and Type 2 DC surge protector | DS252C-48DC/G | | 3 | | 3-phase+N Type 1+2 AC surge protector | DAC1-13S-31-275 | | 3 | | Type 1+2+3 AC surge protector | DS254VG-300/G | | 4 | | 1-pair Data surge protector | DLA-
24D3
| | --- | |
Watch video
| | |
Surge Protection for Wind Turbine installation
. Selection of SPDs
1 - 230V / 400 V | | Description | Model | | --- | ---- | --- | | | Type 1+2+3 surge protector - VG Technology - Uc : 760V |DACN1-25CVGS-30-760 | | | 3-phase Type 2 surge protector - Uc : 760V |DAC50S-30-760 | | | 3-phase Type 2 surge protector - Uc : 800V |DAC50S-31-760-2600DC | 2 - 690 V | | Description | Model | | --- | ---- | --- | | | Type 2+3 surge protector - Uc : 1260V |DACN30VGS-30-1260 | | | Type 2 surge protector - Uc : 1100V |DS41S-1000 | 3 - Datalines | | Description | Model | | --- | ---- | --- | | | 1-pair Telecom-Data surge protector - DIN rail mounting - Ultra compact |DLC-
24D3
/RE | | | RJ45 surge protector for POE++ networks |MJ8-POE-A-SD | 4 - Counter | | Description | Model | | --- | ---- | --- | | | Lightning monitoring system for windturbines |LMS-W |
Download Windturbine flyer
CITEL, PV surge protectors for PV power plants
| --- | --- | --- | --- | | Location | | Model | Description | | PV network | | DS60VGPV-1500G/51 | Type 1 + 2 Photovoltaic surge protector
Iimp 12,5 kA - VG Technology | |PV Network | | DS50VGPVS-1000/12KT1 | Type 1 + 2 Photovoltaic surge protector
Iimp/Itotal : 6.25 / 12.5 kA (10/350µs) - VG Technology | |AC Network | | DAC1-13S-31-275 | Type 1+2 AC surge protector
In 20 kA - Remote signaling | |DATA Network | | DLA-
24D3
| 1-pair pluggable surge protector
In 5 kA - Imax 20 kA - Remote signaling | | --- | --- | |
Download flyer
|
Watch video
| | | |
Citel, SPDs for Energy Storage System ESS
. Surge Protectors selection
| Location | | Description | Model | | --- | --- | ---- | --- | | DC Battery protecgtion | | Kit ESS: 1500Vdc surge protector + Fusible |KIT ESS DDC50S-21Y-1500 | | Main Electrical Panel | | Type 1+2+3 AC surge protector 3-phase+N |DAC1-13VGS-31-275 | | Main Electrical Panel | | Fuse + Holders for 3-phase+N surge protector |SFD1-13S-31 | | Secondary panel | | Type 2 AC surge protector 3-phase+N |DACF25S-31-275 | | Control Sytems | | 1-pair Data surge protector pluggable |DLA-
24D3
| | Control Systems | | POE++ and Cat.6A surge protector |MJ8-POE-C6A | | Connected PV site | | Type 2 PV surge protector 1500Vdc |DPVN40CVGS-21Y-1500 | | Windturbines | | Type 1+2+3 AC surge protector single-phase|DACN1-25VGS-10-440 |
| --- | |
Download flyer
| | |
CITEL, PV surge protectors for industrial and public building
| --- | --- | --- | --- | | Location | | CITEL model | Description | | PV NETWORK | | DPVN-40CVGS-21Y-1200 | Type 2 PV surge protector
In 20kA - Imax 40kA - Remote signaling | |PV NETWORK | | DS50PVS-600/51 | Type 2 PV surge protector
In 15kA - Imax 40 kA - Remote signaling | |AC NETWORK | | DAC50S-31-275 | Type 2 AC surge protector
In 20 kA - Imax 50 kA - Remote signaling | |AC NETWORK | | DAC40CS-31-275 | Type 2 AC surge protector
In 20 kA - Imax 40 kA - Remote signaling - Compact | |DATA NETWORK | | DLA-
24D3
| 1-pair pluggable surge protector
In 5 kA - Imax 20 kA - Remote signaling | | --- | --- | |
Download the flyer
|
Watch video
| | | |
PDF Found
B480-24D3
B280-B480__F_F92096E.pdf
.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail: contact@citel.fr • www.citel.fr R R DBC P R R DP R R D3P Bx80-T Bx80-06DBC Bx80-xxD3 LISTED 120 35 60 B 80-xx Fiche Technique F92096E • Document sujet à modification sans préavis Caractéristiques Boîtier parafoudre 2 et 4 paires Gamme B280,
B480
• Boîtiers «Parafoudre» de 2 et 4 paires • Tous types de lignes Télécom et Data • Circuit de protection amovible • Fixation murale et raccordement vis • Conformité NF EN 61643-21 • Homologué UL497 A P : Eclateur à gaz tripolaire R : Résistance D : Diode d’écrêtage D3 : Diode d’écrêtage tripolaire DBC : Diode tripolaire basse capacité Débit (D3 ou DBC) Tension nominale «2» : 2 paires «4» : 4 paires Référence CITEL B280-T B280-48D3 B280-48DBC B280-
24D3
B280-12D3 B280-06D3 B280-06DBC
B480
-T
B480
-48D3
B480
-48DBC
B480
-
24D3
B280-12D3
B480
-06D3
B480
-06DBC Description Boitier Parafoudre Télécom - 2 ou 4 paires Boitier Parafoudre Data - 2 ou 4 paires Réseau RTC, ADSL, SDSL, SHDSL RNIS-T0, Liaison 48 V RNIS-T0, Liaison 48 V LS, 4-20 mA RS232, RS485 RS422, RS485* MIC/T2, 10BaseT Configuration B280 2 paires 2 paires 2 paires 2 paires 2 paires 2 paires 2 paires
B480
4 paires 4 paires 4 paires 4 paires 2 paires 4 paires 4 paires Tension nominale de ligne Un 150 V 48 V 48 V 24 V 12 V 6 V 6 V Tension de régime perm. max Uc 170 V 53 V 53 V 28 V 15 V 8 V 8 V Courant max de ligne IL 300 mA 300 mA 300 mA 300 mA 300 mA 300 mA 300 mA Frequence max d’utilisation f max > 10 MHz > 3 MHz > 20 MHz > 3 MHz > 3 MHz > 3 MHz > 20 MHz Perte d’insertion - @ fmax < 1 dB < 1 dB < 1 dB < 1 dB < 1 dB < 1 dB < 1 dB Courant de décharge nominal Test 8/20µs x 10 - catégorie C2 In 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA Courant de décharge maximal tenue max. 8/20 µs Imax 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA Courant de choc Test 10/350µs x 2 - catégorie D1 Iimp 2.5 kA 2.5 kA 2.5 kA 2.5 kA 2.5 kA 2.5 kA 2.5 kA Niveau de protection Up 220 V 70 V 75 V 40 V 30 V 20 V 25 V Mise hors service de sécurité Court-circuit Court-circuit Court-circuit Court-circuit Court-circuit Court-circuit Court-circuit Caractéristiques mécaniques Dimensions voir schéma Format boîtier mural Fin de vie interruption de transmission Montage mural (vis non fournies) Température de fonctionnement -40/+85°C Indice de protection IP20 Boîtier Thermoplastique UL94-V0 Circuit de remplacement pour B280 S280-T S280-48D3 S280-48DBC S280-
24D3
S280-12D3 S280-06D3 S280-06DBC Circuit de remplacement pour
B480
S480-T S480-48D3 S480-48DBC S480-
24D3
S280-12D3 S480-06D3 S480-06DBC Conformité aux normes CEI 61643-21 / NF EN 61643-21 / UL497A Certification UL listed Code Article Gamme B280 72726 72774 72754 72773 72772 72771 72751 Gamme
B480
72746 72794 72800 72793 72772 72791 72798 EquiptLigne EquiptLigne EquiptLigne Equipt Ligne * utilisable sur ligne RS485 avec tension fonctionnelle <6V
B280-B480__A_F93075B.pdf
.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail: contact@citel.fr • www.citel.fr R R DBC P R R DP R R D3P Bx80-T Bx80-06DBC Bx80-xxD3 LISTED 120 35 60 B 80-xx Datasheet F93075B • Document could be modified without notice Characteristics 2 and 4-pairs Surge Protectors B280 and
B480
series • 2 and 4-pairs surge protection units • All types of telephone and data lines • Removable protection circuit • Wall mounting and screw connection • IEC 61643-21 compliance • UL497 A P : 3-electrode gas tube R : Resistor D : Clamping diode D3 : 3-pole clamping diode DBC : 3-pole low capacitance diode Bit rate (D3 or DBC) Nominal voltage «2» : 2 pairs «4» : 4 pairs CITEL Model B280-T B280-48D3 B280-48DBC B280-
24D3
B280-12D3 B280-06D3 B280-06DBC
B480
-T
B480
-48D3
B480
-48DBC
B480
-
24D3
B280-12D3
B480
-06D3
B480
-06DBC Description Telecom surge protector box - 2 or 4 pairs Dataline surge protector box - 2 or 4 pairs Network Telephone line, ADSL, SDSL, SHDSL ISDN-T0, 48 V line RNIS-T0, 48 V line LS, 4-20 mA RS232, RS485 RS422, RS485* MIC/T2, 10BaseT SPD configuration B280 2 pairs 2 pairs 2 pairs 2 pairs 2 pairs 2 pairs 2 pairs
B480
4 pairs 4 pairs 4 pairs 4 pairs 2 pairs 4 pairs 4 pairs Nominal line voltage Un 150 V 48 V 48 V 24 V 12 V 6 V 6 V Max. ... Load current IL 300 mA 300 mA 300 mA 300 mA 300 mA 300 mA 300 mA Max. frequency f max > 10 MHz > 3 MHz > 20 MHz > 3 MHz > 3 MHz > 3 MHz > 20 MHz Insertion loss < 1 dB < 1 dB < 1 dB < 1 dB < 1 dB < 1 dB < 1 dB Nominal discharge current 8/20µs Test x 10 - C2 Category In 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA Max. discharge current max. withstand @ 8/20 µs by pole Imax 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA Impulse current 2 x 10/350µs Test - D1 Category Iimp 2.5 kA 2.5 kA 2.5 kA 2.5 kA 2.5 kA 2.5 kA 2.5 kA Protection level Up 220 V 70 V 75 V 40 V 30 V 20 V 25 V Failsafe behavior Short-circuit Short-circuit Short-circuit Short-circuit Short-circuit Short-circuit Short-circuit Mechnical characteristics Dimensions see diagram Format wall mounting box Disconnection indicator transmission interrupt Mounting wall (screws non included) Operating temperature -40/+85°C Protection rating IP20 Housing material Thermoplastic UL94-V0 Spare unit S280-T S280-48D3 S280-48DBC S280-
24D3
S280-12D3 S280-06D3 S280-06DBC Spare unit S480-T S480-48D3 S480-48DBC S480-
24D3
S280-12D3 S480-06D3 S480-06DBC Standards compliance IEC 61643-21 / EN 61643-21 / UL497A Certification UL listed Part number B280 range 72726 72774 72754 72773 72772 72771 72751
B480
range 72746 72794 72800 72793 72772 72791 72798 EquiptLine EquiptLine EquiptLine Equipt Line *usable on RS485 line with operating voltage < 6V
B280-B480__E_F03072B.pdf
.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail: contact@citel.fr • www.citel.fr R R DBC P R R DP R R D3P Bx80-T Bx80-06DBC Bx80-xxD3 LISTED 120 35 60 B 80-xx Ficha Técnica F03072B • Reservado el derecho a moficaciones de este documento Características Cajas de protección para 2 y 4 pares Gama B280,
B480
• Cajas de protección de 2 y 4 pares • Todo tipo de líneas Telecom y Datos • Circuito de protección reemplazable • Fijación mural y conexionado por tornillos • Conforme a la norma IEC 61643-21 • UL497 A P : Descargador tripolar R : Resistor D : Diodo limitador D3 : Diodo limitador tripolar DBC : Diodo tripolar baja capacidad Velocidad (D3 o DBC) Tensión nominal «2» : 2 pares «4» : 4 pares Referencias CITEL B280-T B280-48D3 B280-48DBC B280-
24D3
B280-12D3 B280-06D3 B280-06DBC
B480
-T
B480
-48D3
B480
-48DBC
B480
-
24D3
B280-12D3
B480
-06D3
B480
-06DBC Designación Caja de protección telefonía - 2 o 4 pares Caja de protección data - 2 o 4 pares Red RTC, ADSL, SDSL, SHDSL ISDN-T0, Línea 48 V RNIS-T0, Línea 48 V LS, 4-20 mA RS232, RS485 RS422, RS485* MIC/T2, 10BaseT Configuración protección B280 2 pares 2 pares 2 pares 2 pares 2 pares 2 pares 2 pares
B480
4 pares 4 pares 4 pares 4 pares 2 pares 4 pares 4 pares Tensión nominale de línea Un 150 V 48 V 48 V 24 V 12 V 6 V 6 V Tensión DC máx. de operación Uc 170 V 53 V 53 V 28 V 15 V 8 V 8 V Corriente máx. de línea IL 300 mA 300 mA 300 mA 300 mA 300 mA 300 mA 300 mA Frecuencia máx. f max > 10 MHz > 3 MHz > 20 MHz > 3 MHz > 3 MHz > 3 MHz > 20 MHz Perdida de inserción < 1 dB < 1 dB < 1 dB < 1 dB < 1 dB < 1 dB < 1 dB Corriente de descarga nominal Prueba 8/20µs x 10 - categoria C2 In 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA Corriente de descarga máxima 1 impulso 8/20µs Imax 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA Corriente de choque Prueba 10/350µs x 2 - categoria D1 Iimp 2.5 kA 2.5 kA 2.5 kA 2.5 kA 2.5 kA 2.5 kA 2.5 kA Nivel de protección Up 220 V 70 V 75 V 40 V 30 V 20 V 25 V Final de vida corto-circuito corto-circuito corto-circuito corto-circuito corto-circuito corto-circuito corto-circuito Características mecánicas Dimensiones ver esquema Formato caja Indicador de desconexión interrupción de transmisión Montaje en la pared (entregado sin tornillo) Temperatura de operación -40/+85°C Clase de protección IP20 Material de la caja Termoplástico UL94-V0 Módulo de repuesto S280-T S280-48D3 S280-48DBC S280-
24D3
S280-12D3 S280-06D3 S280-06DBC Módulo de repuesto S480-T S480-48D3 S480-48DBC S480-
24D3
S280-12D3 S480-06D3 S480-06DBC Conformidad con las normas IEC 61643-21 / EN 61643-21 / UL497A Certificación UL listed Código Gama B280 72726 72774 72754 72773 72772 72771 72751 Gama B280 72746 72794 72800 72793 72772 72791 72798 EquipoLínea EquipoLínea EquipoLínea *Utilizable en líneas RS485 con tensión de operación < 6V
I_B280-480_fa__N98071A.pdf
Maintenance Le Boitier B280/
B480
ne nécessite aucune maintenance particulière. ... Installation Instructions Line Surge Protection - B280/
B480
Line Connection By screw terminal : Gauge wire : 0,2 to 1,5 mm² By IDC : wire diameter 0,6 to 0,8 mm Earth Connection On screw M4 : Minimum gauge for the earth : 4 mm² Cable Passage In precut partitions on the cover Box Fitting Wall mounting by screws (not included) Wall mounting by "Velcro" ("AR" version) Installation Recommendation Basic rules : The way line/equipment has to be respected (see diagram) Imperative connection to earth. ... Maintenance: The B280/
B480
box is maintenance free. Following action on a transient overvoltage, the product goes into his initial state. ... N 98 07 1A - Do cu m en t s uj et à m od ifi ca tio n sa ns p ré av is - D oc um en t co ul d be m od ifi ed w ith ou t n ot ice CITEL-2CP - 12, boulevard des Iles - 92441 Issy les Moulineaux cedex - France - Tél. (33) 01 41 23 50 23 - Fax : (33) 01 41 23 50 09 - e-mail : issy@citel2cp.com - web site : http://www.citel2cp.com ou citel.fr Caractéristiques - Characteristics B280-T B380-T
B480
-T Réseau commuté Telephone lines 2 paires/pairs 3 paires/pairs 4 paires/pairs 170 V 190 V 220 V 5 kA court-circuit short-circuit B280-48 B380-48
B480
-48 Télex 4 fils/wires 6 fils/wires 8 fils/wires 48 V 60 V 220 V 5 kA court-circuit short-circuit B280-48D3 -
B480
-48D3 RNIS-T0/ISDN-T0 Ligne 48V / line 48V 1 voie/channel - 2 voies/channels 48 V 60 V 70 V 5 kA court-circuit short-circuit B280-
24D3
-
B480
-
24D3
LS / Leased Lines 4-20 mA LS 4 fils/wires LL - 2 LS 4 fils/wires LL 24 V 30 V 40V 5 kA court-circuit short-circuit B280-12D3 B380-12D3
B480
-12D3 RS232 4 fils/wires 6 fils/wires 8 fils/wires 15 V 20 V 30 V 5 kA court-circuit short-circuit B280-06D3 -
B480
-06D3 RS422 RS485 2 paires/pairs - 4 paires/pairs 6 V 10 V 20 V 5 kA court-circuit short-circuit B280-06DBC -
B480
-06DBC MIC/T2 1 voie/channel - 2 voies/channels 6 V 12V 25 V 5 kA court-circuit short-circuit Références-Part number Utilisations type - Application Configuration protégée - Configuration protected - B280