Contact : +33 1 41 23 50 23 (9:00 – 17:00 CEST)
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
citel and the environment
Service quality
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge protectors
The "surge protection" solution
International Standards
SPD mandatory or not?
GDT overview
Citel's VG Technology
New range SPDs AC-DC
CTC Technology
New PV range: DPVN
New : SPD + Counter
Protection Kit
Products
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Datacenter
E-Mobility
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic/Off-grid Photovoltaic
Industry Photovoltaic
Solar Farms
Agrivoltaic
Energy storage sytems
Water Treatment
Services
Downloading
partnership
Contact
Log in
Create an account
Online sales for France only
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 2 AC surge protector
DS44S-320/G
Type 2 AC surge protector - 3-phase+N
DS44S-320/G
Part Number
461932
Discover our latest innovation : the
DAC50S-31-320
Type 2 AC Multipolar surge protector
In : 20 kA
Imax total : 40 kA
Pluggable module for each phase
Remote signaling
EN 61643-11, IEC 61643-11 compliance
UL1449 ed.5
Datasheet
Installation Sheet
Tender specifications
Contact Us
used mainly for primary protection of single and 4- phase networks at the main electrical panel. They provide common-mode or common and differential mode. This SPD is based on high energy varistor equipped with thermal disconnector and failure indicator, to comply with standards. The DS40 surge protectors are designed to be used in a multipolar configuration to protect single-phase, 3-phase or 3-phase+Neutral AC networks.They are sometimes associated with dedicated N/PE surge protector based on gas tube technology.
Select another reference:
DS44S-320/G
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2
Network
230/400 V 3-phase+N
AC system
TT-TNS
Nominal line voltage
Un
230 Vac
Max. AC operating voltage
Uc
320 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac disconnection
Temporary Over Voltage N/PE (TOV HT)
Without disconnection or with safety disconnection
UT
1200 V/300A/200 ms withstand
Residual Current
Leakage current to Ground
Ipe
None
Operating current
Continious current at Uc
Ic
0.5 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
40 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
40 kA
Connection mode(s)
L/N and N/PE
Protection mode(s)
Common/Differential mode
Protection level L/N
@ In (8/20µs)
Up L/N
1.5 kV
Protection level N/PE
@ In (8/20µs)
Up N/PE
1.5 kV
Residual voltage at 10 kA
@ 8/20µs
Up-10kA
1.3 kV
Admissible short-circuit current
Isccr
25 000 A
Technology
MOV+GDT
SPD configuration
3-phase+Neutral
Connection to Network
By screw terminals: 2.5-25mm² / by bus
Format
Plug-in modular box
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole
Spare module(s)
DSM40-320+DSM40G-600
Remote signaling of disconnection
Output on changeover contact
Dimensions
See diagram
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
UL
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
Fuses type gG - 50 A
×
Description:
Type 2 AC surge protector - 3-phase+N
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
UL / EAC
Technology:
MOV+GDT
SPD configuration:
3-phase+Neutral
Remote signaling of disconnection:
Output on changeover contact
SPD type :
2
Network:
230/400 V 3-phase+N
AC system:
TT-TNS
Max. AC operating voltage :
320 Vac
Residual Current :
None
Max. discharge current :
40 kA
Total Maximum discharge current :
40 kA
Admissible short-circuit current:
25 000 A
CITEL
Reference:
DS44S-320/G
Part Number:
461932
Or equivalent
Select your protection
Discover our new video!
Read more
Citel presents its new range AC and DC SPDs
Read more