Contact : +33 1 41 23 50 30 (9:00 – 17:00 CEST)
Product Selection CMJ8-POE-B
Range Selection CMJ8-POE-B
Pages CMJ8-POE-B
CITEL, ejemplo de protecciones para sistemas de seguridad
. Selección de DPS para sistemas de seguridad 1 - Protecciones para Cámara de Videovigilancia | Ubicación | Referencía Citel | Tipo de protección | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Cámara de Videovigilancia analógica | MSP-VM230-2P | Protección combinada | | | Cámara de Videovigilancia IP | CRMJ8-POE-C6A | Protección POE++ | | | Redes de transmisión de vídeo | CXC06-B/FM | Protección Coaxiale - conector BNC | | | Para redes de datos 10Gigabit Ethernet/POE++ | MJ8-POE-C6A | Protección Ethernet, conexión RJ45 blindaje cableado Cat6A | | | Para redes de datos 10Gigabit Ethernet | MJ8-C6A | Protección Ethernet, conexión RJ45 blindaje cableado Cat6A | |
2 - Protecciones para Sala de Control datos/video | Ubicación | Referencía Citel | Tipo de protección | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Sala de Control | RAK16-E-C6 | DPS en formato Rack19" - Para red Ethernet de alta velocidad 10/100/1000BaseT | |
3 - Protecciones para Cuadro de distribución principal | Ubicación | Referencía Citel | Tipo de protección | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Red AC Entrada de la instalación | DAC1-13S-31-275 | Protección BT de Tipo 1+2+3 | |
4 - Protecciones para Alarma de Incendio y paneles secundarios | Ubicación | Referencía Citel | Tipo de protección | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Alarma de Incendio | DAC40CS-11-275 | Protección BT de Tipo 2 (o 3) - Compacto - Monofásica | | | Alarma de Incendio | DAC40CS-31-275 | Protección BT de Tipo 2 (o 3) - Compacto - Trifásica | |
5 - Protecciones para Control de Acceso | Ubicación | Referencía Citel | Tipo de protección | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Control de Acceso | DLA | Protección Riel Din para datos 1 par | |
6 - Protecciones para iluminación LED | Ubicación | Referencía Citel | Tipo de protección | | | -------------------------------- | ----------------- | ----------------------------------- | ---- | | Caja inferior de iluminación Led para exteriores | DLPM1-230L | Protección Monofásica 230V - montaje caril Din | |
| --- | --- | |
Descarga catalogo
|
Ver video
| | | |
PDF Found CMJ8-POE-B
CMJ8-POE__A_F100202G.pdf

.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail: contact@citel.fr • www.citel.fr DBCP LISTED CMJ8-POE-A CMJ8-POE-A/PCB 140 113 112 80 Data Sheet Characteristics F100202G • Document could be modified without notice P : 3-electrode gas tube DBC : 3-pole Low capacitance diode Line Equipment Outdoor gigabit POE surge protector CMJ8-POEPOE compatible • Outdoor application • Plastic enclosures • IP65 and IP66 • Shielded RJ45 connectors • 2 kA discharge capability • UL497B CITEL Model C*MJ8-POE-A-C5E C*MJ8-POE-B-C5E Description Outdoor gigabit POE-A surge protector Outdoor gigabit POE-B surge protector Network POE-A and Gigabit Ethernet, high POE POE-B and Gigabit Ethernet, high POE Max. data rate 1000 Mbps 1000 Mbps SPD configuration 8 wires + shielded 8 wires + shielded Pin outs (1-2)(3-6)(4-5)(7-8) (1-2)(3-6)(4-5)(7-8) Nominal line voltage Un 48 Vdc 5 Vdc/48 Vdc Max. ... Load current IL 1200 mA 1200 mA Max. frequency f max > 100 MHz > 100 MHz Insertion loss < 1 dB < 1 dB Line/Ground Nominal discharge current 8/20µs Test x10 - C2 category In 2000 A 2000 A Nominal discharge current Line/Line 8/20µs Test x10 - C2 category In 500 A 500 A Impulse current - 2 x 10/350µs Test - D1 Category Iimp 500 A 500 A Protection level Up 70 V 20/70 V Failsafe behavior Short-circuit Short-circuit Mechnical characteristics Spare unit CMJ8-POE-A-C5E/PCB CMJ8-POE-B-C5E/PCB Dimensions see diagram Format Plastic Box with connectors input/output Connection to Network RJ45 shielded connectors female input/output Disconnection indicator transmission interrupt Mounting on plate or pole Operating temperature -40/+85°C Outdoor use yes Housing material Thermoplastic UL94-V0 Standards compliance IEC 61643-21 / EN 61643-21 / UL497B IEEE 802-3ab/3at Part number IP65 version CMJ8-POE-A-C5E 892002 CMJ8-POE-B-C5E 892003 IP66 version (reinforced seal) CGMJ8-POE-A-C5E 892004 CGMJ8-POE-B-C5E 892005

CMJ8-POE__F_F120205D.pdf

.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail: contact@citel.fr • www.citel.fr DBCP LISTED CMJ8-POE-A CMJ8-POE-A/PCB 140 113 112 80 Fiche Technique Parafoudre extérieur pour POE (Power Over Ethernet) Gamme CMJ8-POE Caractéristiques F120205D • Document sujet à modification sans préavis P : Eclateur à gaz tripolaire DBC : Diode basse capacité Ligne Equipement • Pour liaisons POE • Pour application extérieure • Boîtiers plastique • IP 65 et IP 66 • Connecteurs RJ45 blindés • Courant de décharge 2 kA • Homologué UL497B Référence CITEL C*MJ8-POE-A-C5E C*MJ8-POE-B-C5E Description Parafoudre extérieur pour réseaux POE-A Parafoudre extérieur pour réseaux POE-B Réseau POE-A et Gigabit Ethernet, High POE POE-B et Gigabit Ethernet, High POE Débit maximal 1000 Mbps 1000 Mbps Configuration 8 fils + blindage 8 fils + blindage brochage (1-2)(3-6)(4-5)(7-8) (1-2)(3-6)(4-5)(7-8) Tension nominale de ligne Un 48 Vdc 5 Vdc/48 Vdc Tension et Courant max Uc 60 Vdc - 650 mA 7.5 Vdc (1.2.3.6) - 650 mA. 60 Vdc (4.5.7.8) - 650 mA Courant max de ligne IL 1200 mA 1200 mA Frequence max d’utilisation f max > 100 MHz > 100 MHz Perte d’insertion - @ fmax < 1 dB < 1 dB Courant de décharge nominal Ligne/Terre Test 8/20µs x 10 - catégorie C2 In 2000 A 2000 A Courant de décharge nominal Ligne/Ligne Test 8/20µs x 10 - catégorie C2 In 500 A 500 A Courant de choc - Test 10/350µs x 2 - catégorie D1 Iimp 500 A 500 A Niveau de protection Up 70 V 20/70 V Mise hors service de sécurité court-circuit court-circuit Caractéristiques mécaniques Circuit de remplacement CMJ8-POE-A-C5E/PCB CMJ8-POE-B-C5E/PCB Dimensions voir schéma Format Boitier plastique avec connecteurs entrée/sortie Raccordement au réseau connecteur blindé RJ45 femelle en entrée/sortie Fin de vie interruption de transmission Montage sur platine ou sur poteau Température de fonctionnement -40/+85°C Installation extérieure oui Boîtier Thermoplastique UL94-V0 Conformité aux normes IEC 61643-21 / EN 61643-21 / UL497B IEEE 802-3ab/3at Code Article version IP65 CMJ8-POE-A-C5E 892002 CMJ8-POE-B-C5 892003 version IP66 (étanchéité renforcée) CGMJ8-POE-A-C5 892004 CGMJ8-POE-B-C5 892005

CMJ8-POE__E_F130401B.pdf

.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail: contact@citel.fr • www.citel.fr DBCP LISTED CMJ8-POE-A CMJ8-POE-A/PCB 140 113 112 80 Ficha Técnica Características F130401B • Reservado el derecho modificaciones de este documento P : Descargador de gas tripolar DBC : 3-pole Diodo baja capacidad Línea Equipo Protección POE para uso exterior CMJ8-POE • Versión POE • Para uso en exterior • Cajas de plástico • IP65 y IP66 • Conectores RJ45 blindados • Capacidad de descarga : 2 kA • UL497B Referencias CITEL C*MJ8-POE-A-C5E C*MJ8-POE-B-C5E Designación Protección POE-A para uso exterior Protección POE-B para uso exterior Red POE-A y Gigabit Ethernet, high POE POE-B y Gigabit Ethernet, high POE Velocidad máx. 1000 Mbps 1000 Mbps Configuración protección 8 hilos + blindaje 8 hilos + blindaje Pin out (1-2)(3-6)(4-5)(7-8) (1-2)(3-6)(4-5)(7-8) Tensión nominal de línea Un 48 Vdc 5 Vdc/48 Vdc Tensión DC máx. de operación Uc 60 Vdc - 650 mA 7.5 Vdc (1.2.3.6) - 650 mA. 60 Vdc (4.5.7.8) - 650 mA Corriente máx. de línea IL 1200 mA 1200 mA Frecuencia máx. f max > 100 MHz > 100 MHz Perdida de inserción < 1 dB < 1 dB Corriente de descarga nominal Línea/Tierra Prueba 8/20µs x 10 - categoria C2 In 2000 A 2000 A Corriente de descarga nominal Línea/Línea Prueba 8/20µs x 10 - categoria C2 In 500 A 500 A Corriente de choque Prueba 10/350µs x 2 - categoria D1 Iimp 500 A 500 A Nivel de protección Up 70 V 20/70 V Final de vida Corto-circuito Corto-circuito Características mecánicas Módulo de repuesto CMJ8-POE-A-C5E/PCB CMJ8-POE-B-C5E/PCB Dimensiones ver esquema Formato Caja plástica con conectores entrada/salida Conexión a la red conector blindaje RJ45 hembra entrada/salida Indicador de desconexión interrupción de transmisión Montaje sobre pletina o poste Temperatura de operación -40/+85°C Uso exterior si Material de la caja Termoplástico UL94-V0 Conformidad con las normas IEC 61643-21 / EN 61643-21 / UL497B IEEE 802-3ab/3at Código Versión IP65 CMJ8-POE-A-C5E 892002 CMJ8-POE-B-C5E 892003 Versión IP66 (estanqueidad reforzada) CGMJ8-POE-A-C5E 892004 CGMJ8-POE-B-C5E 892005

E184939-20060721-CertificateofCompliance.pdf

For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ annotation http://ul.com/aboutul/locations/ http://ul.com/aboutul/locations/ annotation https://iq.ulprospector.com/ https://iq.ulprospector.com/ page C E R T I F I C A T E O F C O M P L I A N C E Certificate Number UL-US-L184939-112-12706002-1 Report Reference E184939-20060721 Date 23-Apr-2021 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements Model Category Description C2MJ8/505/RJ Isolated loop circuit protectors, for indoor or outdoor use CGMJ8-POE-A-C5 Isolated loop circuit protectors CGMJ8-POE-A-C5e Isolated loop circuit protectors CGMJ8-POE-B-C5 Isolated loop circuit protectors CGMJ8-POE-B-C5e Isolated loop circuit protectors CMJ8-POE-A Isolated loop circuit protectors, for indoor or outdoor use CMJ8-POE-A-C5 Isolated loop circuit protectors CMJ8-POE-A-C5e Isolated loop circuit protectors CMJ8-POE-B Isolated loop circuit protectors, for indoor or outdoor use CMJ8-POE-B-C5 Isolated loop circuit protectors CMJ8-POE-B-C5e Isolated loop circuit protectors CR-CAST-IP67 Isolated loop circuit protector enclosures, for outdoor use CRMJ8-POE-C6 Isolated loop circuit protectors CRMJ8-POE-C6/WNC Isolated loop circuit protectors, for indoor or outdoor use CRMJ8-POE-C6A, Intended for indoor or outdoor use on communication loop circuits which have been isolated from the Public Switched Telephone Network and Electrical Mains. Telecom Protectors CRMJ8-POE-C6A/WNC Isolated loop circuit protectors, for indoor or outdoor use CWMJ8-POE-C6 Isolated loop circuit protectors, for indoor or outdoor use CWMJ8-POE-C6A Isolated loop circuit protectors, for indoor or outdoor use MJ8-C6A, Intended for indoor use on communication loop circuits which have been isolated from the Public Switched Telephone Network and Electrical Mains. ... For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ annotation http://ul.com/aboutul/locations/ http://ul.com/aboutul/locations/ page C E R T I F I C A T E O F C O M P L I A N C E Certificate Number UL-US-L184939-112-12706002-1 Report Reference E184939-20060721 Date 23-Apr-2021 MJ8-CAT5E Isolated loop circuit protectors, for indoor use MJ8-ISDN Isolated loop circuit protectors, for indoor use MJ8-POE-A Isolated loop circuit protectors, for indoor use MJ8-POE-B Isolated loop circuit protectors, for indoor use MJ8-POE-C6A, Intended for indoor use on communication loop circuits which have been isolated from the Public Switched Telephone Network and Electrical Mains. Telecom Protectors ZS-CAT5E-POE Isolated loop circuit protectors, for indoor use Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL.

E184939-20060721-CertificateofCompliance.pdf

For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ annotation http://ul.com/aboutul/locations/ http://ul.com/aboutul/locations/ annotation https://iq.ulprospector.com/ https://iq.ulprospector.com/ page C E R T I F I C A T E O F C O M P L I A N C E Certificate Number UL-US-L184939-112-12706002-1 Report Reference E184939-20060721 Date 23-Apr-2021 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements Model Category Description C2MJ8/505/RJ Isolated loop circuit protectors, for indoor or outdoor use CGMJ8-POE-A-C5 Isolated loop circuit protectors CGMJ8-POE-A-C5e Isolated loop circuit protectors CGMJ8-POE-B-C5 Isolated loop circuit protectors CGMJ8-POE-B-C5e Isolated loop circuit protectors CMJ8-POE-A Isolated loop circuit protectors, for indoor or outdoor use CMJ8-POE-A-C5 Isolated loop circuit protectors CMJ8-POE-A-C5e Isolated loop circuit protectors CMJ8-POE-B Isolated loop circuit protectors, for indoor or outdoor use CMJ8-POE-B-C5 Isolated loop circuit protectors CMJ8-POE-B-C5e Isolated loop circuit protectors CR-CAST-IP67 Isolated loop circuit protector enclosures, for outdoor use CRMJ8-POE-C6 Isolated loop circuit protectors CRMJ8-POE-C6/WNC Isolated loop circuit protectors, for indoor or outdoor use CRMJ8-POE-C6A, Intended for indoor or outdoor use on communication loop circuits which have been isolated from the Public Switched Telephone Network and Electrical Mains. Telecom Protectors CRMJ8-POE-C6A/WNC Isolated loop circuit protectors, for indoor or outdoor use CWMJ8-POE-C6 Isolated loop circuit protectors, for indoor or outdoor use CWMJ8-POE-C6A Isolated loop circuit protectors, for indoor or outdoor use MJ8-C6A, Intended for indoor use on communication loop circuits which have been isolated from the Public Switched Telephone Network and Electrical Mains. ... For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ annotation http://ul.com/aboutul/locations/ http://ul.com/aboutul/locations/ page C E R T I F I C A T E O F C O M P L I A N C E Certificate Number UL-US-L184939-112-12706002-1 Report Reference E184939-20060721 Date 23-Apr-2021 MJ8-CAT5E Isolated loop circuit protectors, for indoor use MJ8-ISDN Isolated loop circuit protectors, for indoor use MJ8-POE-A Isolated loop circuit protectors, for indoor use MJ8-POE-B Isolated loop circuit protectors, for indoor use MJ8-POE-C6A, Intended for indoor use on communication loop circuits which have been isolated from the Public Switched Telephone Network and Electrical Mains. Telecom Protectors ZS-CAT5E-POE Isolated loop circuit protectors, for indoor use Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL.

I_CRMJ8-POE-C6_&_C6A_N200204b.pdf

date 2024-02-28T14:19:38Z pdf:PDFVersion 1.5 xmp:CreatorTool Adobe Illustrator CC 23.0 (Windows) pdf:docinfo:title I_CRMJ8-POE-C6 & C6A_N200204_A1 stream_content_type application/pdf pdf:hasXFA false access_permission:can_print_degraded true xmpMM:History:Action saved xmpMM:History:Action saved dc:format application/pdf; version=1.5 pdf:docinfo:creator_tool Adobe Illustrator CC 23.0 (Windows) access_permission:fill_in_form true xmpMM:History:When 2012-09-28T16:54:31Z xmpMM:History:When 2020-02-21T15:11:56Z pdf:encrypted false dc:title I_CRMJ8-POE-C6 & C6A_N200204_A1 xmp:CreateDate 2020-02-21T15:11:58Z modified 2024-02-28T14:19:38Z xmpMM:History:SoftwareAgent Adobe Illustrator CS5 xmpMM:History:SoftwareAgent Adobe Illustrator CC 23.0 (Windows) pdf:hasMarkedContent false xmpMM:History:InstanceID xmp.iid:1F8A9E687C09E211B7E094CDB50FD317 xmpMM:History:InstanceID xmp.iid:e2dab57e-f1bf-d24f-bac9-c9cb0d26fa77 xmp:ModifyDate 2024-02-28T15:19:38Z pdf:docinfo:creator mm meta:author mm meta:creation-date 2020-02-21T13:11:58Z created 2020-02-21T13:11:58Z access_permission:extract_for_accessibility true Creation-Date 2020-02-21T13:11:58Z xmpMM:DerivedFrom:DocumentID xmp.did:57926de1-835c-4447-93f1-197e6c7c49fb Author mm producer Adobe PDF library 15.00 pdf:docinfo:producer Adobe PDF library 15.00 access_permission:modify_annotations true dc:creator mm dcterms:created 2020-02-21T13:11:58Z Last-Modified 2024-02-28T14:19:38Z dcterms:modified 2024-02-28T14:19:38Z xmpMM:DocumentID xmp.did:e2dab57e-f1bf-d24f-bac9-c9cb0d26fa77 Last-Save-Date 2024-02-28T14:19:38Z pdf:docinfo:modified 2024-02-28T14:19:38Z meta:save-date 2024-02-28T14:19:38Z Content-Type application/pdf stream_size 1513561 xmp:MetadataDate 2024-02-28T15:19:38Z X-Parsed-By org.apache.tika.parser.DefaultParser X-Parsed-By org.apache.tika.parser.pdf.PDFParser creator mm pdf:producer Adobe PDF library 15.00 access_permission:assemble_document true xmpTPg:NPages 2 pdf:hasXMP true access_permission:extract_content true access_permission:can_print true xmpMM:DerivedFrom:InstanceID uuid:5a31a0ba-6586-466b-b946-b694de2a76bd access_permission:can_modify true pdf:docinfo:created 2020-02-21T13:11:58Z I_CRMJ8-POE-C6 & C6A_N200204_A1 page Power + Ethernet = OK Technical Data MaintenanceWiring Application example INSTALLATION INSTRUCTIONS - NOTICE D'INSTALLATION NOTICIA DE INSTALACIÓN - INSTALLATIONSHINWEISE ISTRUZIONI PER L'INSTALLAZIONE INSTRUCOES DE INSTALACAO - MONTÁŽNÍ NÁVOD РУКОВОДСТВО ПО МОНТАЖУ - 安装指导书 Outdoor Surge Protector for PoE dataline Parafoudre d’exterieur pour lignes POE CRMJ8 series AC Network Input / output connection Ground connection Protection class RJ45 shielded Crimp terminals IP66 Wall or Pole Application CR M J8 -P O E- C6 CR M J8 -P O E- C6 A Mounting Maximum data rate Cable category Max. voltage between pairs (power) Outdoor-Gehäuseschutzmodul für PoE-Verbindung DPSoutdoor para lineas PoE - Protezione esterra per linea PoE - Max. ... X Input Output CRMJ8-POE-C6 POE A & B Surge Protector Input Output N200204b Input Output POE input Toward POE equipment PE Input Output Power + Ethernet = OK Min. pole size Max. pole size * 5 cm 20 cm If a larger pole diameter is used then use two pole kits in series * POE input Toward POE equipment PE Input Output P/N 1.97 inch 7.88 inch Fit protector as close as possible to the POE cable entry point into the building ** DEFECTIVE 13100 ft max. 4000 m max... Humidity range 5% to 95% CMJ8-POE-C6/PCB or CMJ8-POE-C6A/PCB 10 Gigabit Ethernet - CAT6A POE and Gigabit Ethernet 1000 Mbps 60 Vdc Ref. : CR-WM-KIT Code : 581532 Ref. : CR-PM-KIT Code : 581531 page SAFETY INSTRUCTIONS CONSIGNES DE SECURITE SICHERHEITSHINWEISE ADVERTENCIA DE SEGURIDAD AVVERTENZE IMPORTANTI WSKAZÓWKI BEZPIECZEŃSTWA VARNOSTA NAVODILA VEILIGHEIDSVOORSCHRIFTEN BEZPEČNOSTNÉ POKYNY SIKKERHEDSANVISNINGER SÄKERHETSANVISNINGAR AVISOS IMPORTANTES МЕРЫ БЕЗОПАСНОСТИ BEZPEČNOSTNÍ POKYNY 安全须知 WARNUNG !